Page 31

Screen:

Key:

Compsee, Inc. TurboWedge-1199

EDIT GOOD MAIN MENU 1-TERMINAL 2-GENERAL 3-SCANNER 4-SERIAL 5-CODES 6-EDIT 7-STATUS 8-MISC 9-EXIT SELECT GROUP 9<Enter>

31

Page 32

V. GENERAL PROGRAM SELECTIONS 1.

TERMINAL SELECTIONS a) INTERFACE SELECTION - KEYBOARD WEDGE Menu Page = Terminal Selection - Page A This parameter programs the unit for the terminal it is attached via the keyboard. Sequence of operation for programming the terminal selection a) Scan “ENTER TERMINAL SELECTION” b) Scan the two (2) digit number corresponding to the terminal desired. c) Example: For an IBM 3180-1 Terminal, Scan a “0” then a “5” on the Bar Code Menu Page. d) Scan “EXIT TERMINAL SELECTION” b) INTERFACE SELECTION - SERIAL OUTPUT Menu Page = Terminal Selection This parameter programs the unit for RS 232 serial communications. • External Power Supply Required • Set Communication Parameters using the Serial I and II Menu Pages.

2.

•

Single Port RS 232 - Data Output = Port 2 (Models 1 or 2) a) Scan “ENTER TERMINAL SELECTION” b) Single Port RS 232 ID = 31 c) Scan “3” then a “1” on the Bar Code Menu Page. d) Scan “EXIT TERMINAL SELECTION”

•

Dual Port RS 232 a) Scan “ENTER TERMINAL SELECTION” b) Dual Port RS 232 ID = 32 c) Scan “3” then a “2” on the Bar Code Menu Page. d) Scan “EXIT TERMINAL SELECTION”

GENERAL I MENU

Menu Page = General I - Page B This menu page is used to program various functions that apply to all input through the unit. The DEFAULT Selections for the General Menu are indicated on the menu by an asterisk "*" BEEPER VOLUME = INPUT INHIBIT CHECK = KEYBOARD TYPE = INTERCHARACTER DELAY = INTERFUNCTION DELAY = NUMERIC KEYPAD = •

7 OFF PRIMARY 00 (NONE) 00 (NONE) OFF

Beeper Volume The unit will emit a beep after each successful read. This beep can range in volume from 0 (OFF) to 7 (HIGH). The default is 7 (HIGH).

Compsee, Inc. TurboWedge-1199

32

Page 33

•

Input Inhibit Check In most terminal environments, the terminal is often “inhibited” from sending data to the host CPU. This happens after a screen or page of data is sent to the host CPU by the operator activating the “XMIT”, “REC ADV”, or “ENTER” key. Further input from the keyboard is ignored by the terminal as long as input is inhibited by the host. Reference Appendix A for terminals which allow monitoring of the Input Inhibit line. Reference Appendix G for terminals that require the installation of leads inside the terminal to monitor input inhibit. Reference Appendix F for further usage of Input Inhibit during data transmission

•

Keyboard Type Most terminals supported by the unit can have one of two styles of keyboards attached to it. Through programming you can change from one type to another. The types of keyboards are often referred to as: ♦ Typewriter versus Data Entry ♦ 122 Keys versus 102 Keys ♦ No Caps Lock versus Caps Lock NOTE: Caps Lock on Versus Caps Lock Off Output of alpha data to the terminal is affected by the ON or OFF state of the CAPS LOCK key. Under default , the unit assumes that CAPS LOCK is OFF and sends the "SHIFT" key prior to the output of alpha data. The alpha data then appears as upper case characters. However, if the terminal program functions with CAPS LOCK ON, the addition of the "SHIFT" key sends the data to the terminal as lower case alpha characters. If this is the case, the Keyboard Type should be set to Secondary.

•

Intercharacter Delay This parameter is used to establish an intercharacter delay time of 10 to 990 milliseconds. The delay will appear after each character is transferred to the terminal screen. This delay parameter should be specified if you find that the terminal cannot keep up with the speed at which the unit is sending data to the screen, or if the host program is inserting multiple keyboard functions into the data being entered.

•

Interfunction Delay This parameter is used to establish an interfunction delay time of 10 to 990 milliseconds. The delay will appear after each keyboard function is transferred to the terminal screen. This delay parameter should be specified if you find that the terminal cannot keep up with the speed at which the unit is sending data to the screen, or if the host program is inserting multiple keyboard functions into the data being entered.

•

Numeric Keypad Under normal conditions, the number keys at the top of the keyboard are emulated by the keyboard wedge when entering numeric data. In the event that an application calls for the depression of the numeric keys on the right-hand keypad, this parameter should be turned on. Once on, numeric data transmitted from the wedge will emulate the depression of these keys.

Compsee, Inc. TurboWedge-1199

33

Page 34

3. GENERAL II MENU Menu Page = General II - Page C The second General Menu is also used to program various functions that apply to input through the unit. The DEFAULT Selections for the General Menu are indicated on the menu by an asterisk "*" MAGNETIC TRACK BUFFERING SCALE SOLICIT RECORD SWITCHES 1) Output Edited Records Only 2) Mag Stripe Reverse 3) ---4) Turbo Mode - HP, Wyse, PC/AT = OFF 5) ---6) IBM PC/AT without Keyboard = OFF 7) Laser with Marker Beam 8) Laser with Auto Sense SET PAUSE TIME •

= TRACK 2 = ON = NONE = OFF = OFF = OFF = OFF = OFF = OFF = NONE

Magnetic Track This parameter is used to establish which track or tracks are to be read from the attached magnetic stripe reader. Magnetic Stripe Ports TurboWedge 1 = Port 2 The options are: 1 = Track 1 2 = Track 2 3 = Track 3 4 = Dual Track 1 & 2

TurboWedge 2 = Port 3

5 = Dual Track 2 & 3 6 = Dual Track 1 & 3 7 = Triple Track 1,2 & 3 8 = Any Valid Track

NOTE: “0” = TurboWedge 1, Port 2, RS 232 Input Since Port 2 of the TurboWedge 1 can also be configured for RS 232 Input. If an RS 232 Input device is attached to Port 2, this parameter should be set to “0”. •

Buffering If the buffer is ON (Default), and the attached terminal is not ready to accept data, the unit will buffer up to 32 entries. If the buffer is OFF, the unit will not accept another entry until the record previously read has been transmitted to the attached terminal and the buffer has been cleared.

•

Scale Solicit Record Typical usage for this parameter is when for an application requires a scale to be attached to the RS 232 auxiliary port. Most scales require that a record be sent to it prior to initiating the response from the scale.

Compsee, Inc. TurboWedge-1199

34

Page 35

This parameter is used to set the ASCII character or characters that will be transmitted. The defined character(s) will be held in the units buffer under the Hex 05 Function Code - Referred to as SOLA (Solicit). Whenever the Hex 05 Function Code is programmed into the output record (preamble, postamble, output edit) the solicit record in the buffer will be sent out to the attached scale. Once received, the scale will respond by transmitting the data string containing the weight information back to the wedge. A maximum of four (4) ASCII characters can be programmed. The default value for this parameter is "NONE". Example: The scale requires a “P” followed by a “Carriage Return” sent to it prior to it transmitting the weight data out the RS 232 Port. Program the unit for a Scale Solicit Record of 50, 0D. Whenever the SOLA Function Code (Hex 05) (Postamble or Singular Function Code) is inserted in the data string, the record (Hex 500D) will be transmitted out the RS 232 port to the scale, causing the scale to respond with the transmission of the weight data back to the wedge. •

Selector Switch 1: Output Edited Records Only This parameter is used to establish what input records will be transmitted to the terminal. If this parameter is ON, only the records that have been defined and edited via the EDIT Program Parameters will be passed through to the terminal. See Section IX for instructions on Edit programming. If this parameter is OFF (Default), all input will be passed through to the terminal. This includes both edited and non-edited records.

•

Selector Switch 2 : MSR Reverse If this parameter is on, a magnetic stripe card can be passed through the reader in either direction. If this parameter is off, a magnetic stripe card can only be passed through the reader in a forward direction.

•

Selector Switch 3: NOT ACTIVE

•

Selector Switch 4: Turbo Mode - HP, Wyse, PC/AT The application software running on an HP, Wyse or PC/AT terminal can have an effect on the data that is transmitted from the wedge. Based on the applications response time, it is possible for keyboard data to be eliminated during the transmission. Therefore under the normal HP, Wyse and PC/AT set-up, this is taken into account. The transmission rate from the unit is such that data will not be lost. If the rate of transmission appears to be too slow, turn on the Turbo Mode Switch. This will increase the speed of transmission. This mode should be tested with the application prior to its use in a production environment. If this parameter is off, data transmission will remain at the factory setting. If this parameter is on, the data transmission speed will be increased.

Compsee, Inc. TurboWedge-1199

35

Page 36

•

Selector Switch 5: NOT ACTIVE

•

Selector Switch 6: IBM PC/AT without keyboard If the unit is attached to an IBM PC/AT without a keyboard, this parameter should be set to ON. During the power up sequence, the terminal checks for the presense of a keyboard. If the keyboard is not present, the TurboWedge will send back the required “keyboard present” signal to the terminal. If OFF, a keyboard must be attached to avoid the error condition that is emitted by the terminal when it checks for the presence of a keyboard during the start-up sequence.

•

Selector Switch 7: Laser with Marker Beam If the Marker Beam option is installed on the attached laser input device, Switch 7 should be turned on. When ON, the unit will delay the start of decode to allow time for the marker beam.

•

Selector Switch 8: Laser with Auto Sense If the Auto Sense option is installed on the attached laser input device, Switch 8 should be turned on.

•

Set PAUSE TIME Description: Allows the user to set ASCII Location 15 for PAUSE of 0 to 10 seconds. When ASCII Location 15 is inserted into the output data record it will cause the unit to pause the programmed amount of time. Typical Use: Used when function codes such as "ENTER", "REC ADV", or "XMIT" are inserted into the output record. These key functions normally cause a screen change during the output of data. If these functions are embedded within the output of a record via a programmed edit, there is a possibility of data loss if the host systems response time is slower then the units transmission speed. If a "PAUSE" is inserted after the function, the unit will hold the remainder of data to be output in buffer and continue transmission at the end of the pause. Menu Implementation: 1. Scan 2. Scan 3. Scan 4. Scan -

ENTER GENERAL II Selections SET PAUSE TIME The two (2) digits (00 - 99) to represent the EXIT GENERAL II Selections length of time for the pause.

NOTE: The number scanned will be multiplied by 100 milliseconds. 10 = 1000 milliseconds or 1 second, 80 = 8000 milliseconds or 8 seconds

Compsee, Inc. TurboWedge-1199

36

Page 37

Example: 1. Scan - ENTER GENERAL II Selections 2. Scan - SET PAUSE TIME 3. Scan - 20 (20 = 2 Seconds) 4. Scan - EXIT GENERAL II Selections 5. Scan - ENTER SCANNER PORT Selections 6. Scan - POSTAMBLE 7. Scan - 0D 15 (NEW LINE & PAUSE) 8. Scan - EXIT SCANNER PORT Selections If a series of bar codes are read, the unit will output after each bar code the NEW LINE Key and then pause for 2 seconds before sending the next bar code read.

VI. SCANNER PORT MENU Menu Page = Scanner Port - Page D This menu page is used to program various functions that apply to input through the Scanner Port. The DEFAULT Selections for the Scanner Port Menu are: PREAMBLE POSTAMBLE LASER REDUNDANCY FUNCTION CODES CODE IDENTIFICATION = OFF AUTOSCAN MULTI SCAN •

Indicated on the menu by an asterisk "*"

= NONE = NONE = OFF = OFF = OFF = OFF

Preamble & Postamble The user may specify a Preamble and/or Postamble (maximum of 16 characters each) to precede or follow each code scanned. Preamble

Scanned Data

Postamble

NOTE: Embedding the "ENTER, "REC ADV", or "XMIT" keys within the data being transmitted will result in either a portion of, or all of the data following these key functions not be transmitted to the screen. To prevent loss of data, only use the "ENTER", "REC ADV", or "XMIT" keys as the last character of the Postamble or program in an adequate “Pause” after the function to allow for a new screen to appear. When programming for a Preamble and/or a Postamble, the Hex representation for each character desired must be entered. Refer to either the Key Code Chart in Appendix C. NOTE: Any programmed Preamble & Postamble will not be included in the output for a record that has been edited. If a Preamble or Postamble is required on an edited record, it must be included in the edit.

Compsee, Inc. TurboWedge-1199

37

Page 38

•

Laser Redundancy When enabled, the unit will require two (2) identical reads of a bar code to be decoded prior to accepting the bar code input and signaling for the light source to be turned off on the input device.

•

Function Codes If Keyboard Function Codes (i.e., Field Forward, Xmit, etc.) are embedded within the bar codes that are being read, this feature must be turned ON. See Appendix C for a listing of the keyboard functions and the programmed codes associated with each function.

•

Code Identification This parameter programs the unit to precede the transmission of each bar code read with a character that identifies the type of symbology the code was printed in. The symbologies and their identifiers are as follows: CODABAR = a CODE 3 OF 9 = b EAN = d I 2 OF 5 = e CODE 128 = j CODE 11 = h PLESSEY = g

•

UPC-A 2 OF 5 CODE 93

= c = f = I

AutoScan When turned On, the attached laser input device is automatically enabled and will “blink” and attempt to detect a bar code. When the laser detects a bar code it will will activate fully and attempt to decode it. After a successful read, the laser will be turned off. The time between the off and on stages of the laser is programmed by the user and variable between 100 milliseconds and 9.9 seconds. If during an attempted read a bar code is not present, the laser will turn off.

•

Multi Scan When turned On, the attached laser input device, when triggered, will be activated and stay on as long as bar codes are being decoded. The laser will turn off when either the trigger is released or a successful decode has not occurred within a period of approximately 3 seconds. Programming options for Multi Scan include: ♦ Time between reads ♦ Allowing for the identical bar codes to be read

00 - 99 On/Off

(x10 milliseconds)

VII. SERIAL INPUT/OUTPUT SELECTIONS Menu Pages - Serial I & Serial II - Pages E, F & G The Serial I and II menu pages are used to program various functions that pertain to either serial input or output through the RS 232 Auxiliary Port or Dual/Single Port RS 232 Output.

Compsee, Inc. TurboWedge-1199

38

Page 39

1.

SERIAL I SELECTIONS

The DEFAULT Selections for the Serial I Menu are:

(indicated by an asterisk on the menu)

PREAMBLE = NONE POSTAMBLE = NONE RECORD TERMINATOR = "0D" FUNCTION CODES = OFF •

Preamble & Postamble (RS 232 Input) Through programming, the user may specify a Preamble and/or Postamble (maximum of 16 characters each) to precede or follow all data being transmitted that was received from the RS 232 auxiliary input port (Port 2 - Models 1 & 2). Preamble

RS 232 Input Data

Postamble

NOTE: Embedding the "ENTER, "REC ADV", or "XMIT" keys within the data being transmitted will result in either a portion of, or all of the data following the these key functions not be transmitted to the screen. To prevent loss of data, only use the "ENTER", "REC ADV", or "XMIT" keys as the last character of the Postamble or program in an adequate “Pause” after the function to allow for a new screen to appear. When programming for a Preamble and/or a Postamble, the Hex representation for each character desired must be entered. Refer to either the Key Code Chart in Appendix C. NOTE: Any programmed Preamble & Postamble will not be included in the output for a record that has been edited. If a Preamble or Postamble is required on an edited record, it must be included in the edit. •

Record Terminator (RS 232 Input) Each data record that the unit receives from the RS 232 auxiliary input port (Port 2, Models 1 & 2) is held in a buffer until a Record Terminator is received. Once received, the unit will discard the Record Terminator, process the data received and then transmit the data. One character must be programmed as the Record Terminator. Any of the ASCII characters may be used as a Record Terminator. The Record Terminator will NOT appear on the screen. The only function of the Record Terminator is for usage by the unit to signal the end of a data record. When programming for a Record Terminator, the Hex representation for each character desired must be entered. Refer to the Key Code Chart in Appendix C. If the last character of the data does not match the Record Terminator specified, no data will be sent to the screen.

•

Function Codes (RS 232 Input) If Keyboard Function Codes (i.e., TAB, ENTER, etc.) are embedded within the data being received from the RS 232 Port (Port 2 - Models 1 & 2) and are to be transmitted as keyboard functions, this feature must be turned ON. If OFF, keyboard function characters received by the unit will be ignored.

Compsee, Inc. TurboWedge-1199

39

Page 40

2.

SERIAL II SELECTIONS

Note the presence of both the Enter Aux Port Selection and Enter Host Port Selections. Enter Aux Port Selections TurboWedge 1 - Use for all Serial II Selections TurboWedge 2 - Use for data input through Input Port 2 Enter Host Port Selections TurboWedge 1 - Not a valid entry TurboWedge 2 - Use for data output selections

(Interface connection)

The DEFAULT Selections for the Serial II Menu are indicated by an asterisk on the menu. BAUD RATE = 9600 PARITY = EVEN WORD LENGTH = 7 BITS STOP BITS = 1 STOP BIT DUAL/SINGLE PORT FLOW CONTROL = NONE SERIAL INPUT PROTOCOL = RECORD •

Baud Rate (RS 232 Input or Output) Program the Baud Rate for serial transmission compatibility with the external device connected to the RS 232 Input Port or to the host system if data output is RS 232 Single or Dual Port. If the Baud Rate compatibility is not achieved, a series of beeps will be emitted. Selections include: 300 = 600 = 1200 = 2400 =

•

4800 = E 9600 = F 19200 = G 38400 = H

57600 = I (TurboWedge 2 only) 115700 = J (TurboWedge 2 only)

Parity (RS 232 Input or Output) Program Parity Checking for serial transmission compatibility with the external device connected to the RS 232 Input Port or to the host system if data output is RS 232 Single or Dual Port. If Parity compatibility is not achieved, a series of beeps will be emitted. Selections include: MARK = EVEN = NONE =

•

A B C D

A C E

SPACE = ODD =

B D

Word Length (RS 232 Input or Output) Program Word Length for serial transmission compatibility with the external device connected to the RS 232 Input Port or to the host system if data output is RS 232 Single or Dual Port. If Word Length compatibility is not achieved, a series of beeps will be emitted. Word Length can be set to either 7 or 8 bits.

Compsee, Inc. TurboWedge-1199

40