3.

SERIAL BATCH

This programming involves creating an ASCII file containing the programming parameters and then transmitting the ASCII file to the unit via the RS 232 input port (Port 2). A cable is required that would run from the host device to the RS 232 input port (Port 2) of the unit. Contact Compsee Customer Service for the correct cable configuration. The units serial port setting must match the host’s settings (e.g. Baud Rate, Parity, Start & Stop Bits). The ASCII file created takes on the same attributes as the Bar Code Batch Programming. START / STOP AND SELECTION SEPARATORS Start String = -(2 Dashes) End String = -(2 Dashes) Selection Separators = (1 Dash) Note:

Parameters from any given menu page, in any given order are allowed in a batch string.

EXAMPLES • Select a Scanner Postamble of “ABC” followed by the TAB key (Codes 41,42,43,09) --D241424309-• • •

Program Terminal ID to 01 Program Beeper Volume to 3 Program Keyboard Type to secondary --A101-B13-B3B--

• • •

Program Terminal ID to 15 Program Scanner Postamble to 0D Edit Code 39 five digit bar code, match and remove first digit, and add “CR” Input = A1234 Output = 1234 “CR” Note: Prior to the first Edit the “J0” sequence must be received by the unit. After the last Edit entered add the “JC” sequence. --A115-D20D-J0-J101-J21-J3B-J405-J502-J601-J7411-J604-J70D-J800-JB02-JC--

Compsee, Inc. TurboWedge-1199

21

Page 22

4.

CLONING

NOTE: Reference Program Mode Menu in the back of the manual. Cloning is a programming method that copies the setup from one unit to another. Once you have programmed and tested one unit and verified that the data input and output is correct, you can use that unit as the “master” to program the other unit in with the identical program. Cloning is achieved by transmitting the program from the master to the attached unit via cable # 02TC016 from Port 2 of the master to Port 2 of the unit to be cloned. CLONING A UNIT 1: Power up both the master and receiving unit. Power can be supplied from a keyboard interface or from an external power supply. 2: Connect the master and receiving unit. Plug Cable # 02TC016 into Port 2 of both units. Cable # 02TC016 - Pin Outs MASTER Unit RECEIVING Unit RXD 1 -------3 TXD TXD 3 -------> 1 RXD CTS 5 -------10 RTS GROUND 7 -------7 GROUND RTS 10 <------5 CTS 3. 4. 5. 6. 7.

RECEIVING Unit Scan the CLONE IN label (Program Mode Menu) MASTER Unit Scan the CLONE OUT label (Program Mode Menu) The Master Unit will transmit to the Receiving Unit the same parameters that it was programmed for. Disconnect the Aux Port Cable from the Receiving Unit. Recycle power on the Receiving Unit to initialize the transmitted parameters.

Compsee, Inc. TurboWedge-1199

22

Page 23

5.

WinCape

NOTE: Reference Program Mode Menu in the back of the manual. WinCape is a copyright software program by Compsee, Inc. Download Wincape from Compsee’s Electronic Response and Information Center (ERIC) at www.compsee.com. It is a means by which the user can configure the parameters for the unit using an IBM PC or compatible and the WinCape software. REQUIREMENTS• IBM PC or Compatible • Windows (3.X and above) • WinCape Software • TurboWedge • Bar Code Scanner connected to Port 1 • RS 232 Cable – 02TC014 - Comm Port 1 or 2 is user specified • Power Supply - The TurboWedge can be interfaced to a terminal and be receiving power from the keyboard connection. WinCape should be used in conjunction with the TurboWedge Manual. The program screens merely follow the printed menu pages from the manual, allowing the operator to select the desired parameter and make the variable selections using function keys. When all parameters needed have been selected, the set-up can be downloaded to the TurboWedge and/or saved to a file on the PC. Another utilization of WinCape allows for the uploading to the PC the parameters from a previously configured TurboWedge. The configuration can then be saved for future use. After the user has completed the setup configuration on the PC, the TurboWedge needs to be connected to the Serial Port of the PC and to a power source. Prior to communicating with the TurboWedge, scan the "Enable WinCape Programming" label located on the Program Mode Menu Page. This action temporarily sets up the serial port parameters so that the TurboWedge can communicate with the PC. Once the download is complete and power to the TurboWedge has been recycled, the set-up for the serial port will be set to the configuration that was downloaded to it. At the beginning of the download the TurboWedge will issue a High-Low beep sequence. Upon successful load, a High-High beep sequence will be issued.

Compsee, Inc. TurboWedge-1199

23

Page 24

6.

SYMBOLOGY VALIDATION

NOTE: Reference Program Mode Menu in the back of the manual. Symbology Validation is the simplest programming method. In effect, you “teach” the unit to accept only the bar code or codes that the particular workstation can input. 1. 2. 3. 4.

Scan Enter Symbology Validation Scan a bar code representing the minimum length of the particular code that can be read. Scan a bar code representing the maximum length of the particular code that can be read. Scan Exit Symbology Validation

EXAMPLE At a particular workstation the operator should only be reading data represented by the following three bar code. The unit should be programmed in the following manner using Symbology Validation. Code 128 - 6 Digits Code 128 - 14 Digits Code 3 of 9 - 8 Digits 1) 2) 3) 4) 5)

Scan Enter Symbology Validation Scan a 6 digit Code 128 bar code (Minimum Length) Scan a 14 digit Code 128 bar code (Maximum Length) Scan the 8 digit Code 3 of 9 bar code (Maximum Length) Scan Exit Symbology Validation

Compsee, Inc. TurboWedge-1199

24

Page 25

7.

ON-SCREEN

The On Screen Programming Method (OSPM) lets you display the program parameters on your screen. You can select the parameters using the host terminal keyboard and make the setting changes that are required. SET-UP Prior to entering On Screen Programming Mode (OSPM), the host terminal must be prepared to display data without affecting the application program. Best results are obtained by entering a word processor such as “NotePad”. This allows the user to review data that may roll off the screen during the programming session. 1.

There are three methods that can be used to enter the On Screen Programming Mode. • • •

Using a Bar Code Scanner attached to Port 1 of the unit: Scan the On Screen Programming Mode bar code found on the Programming Mode page in the menu section of the manual (Page M). Using a Serial Input Device attached to Port 2 of the unit. Transmit the following sequence of characters. C$$$-8C Using a Magnetic Stripe Card Reader attached to Port 2 of Model 1 or Port 3 of Model 2. Swipe a card that has been encoded with C$$$-8C.

2.

Upon entering OSPM, the Turbo wedge will produce a Hi-Lo beep sequence. The following menu will appear on the host terminal screen: MAIN MENU 1-TERMINAL 2-GENERAL 3-SCANNER 4-SERIAL 5-CODES 6-EDIT 7-STATUS 8-MISC 9-EXIT SELECT GROUP __

3.

At the SELECT GROUP prompt, key in the numeric digit followed by <ENTER> for the desired menu. A corresponding sub menu will then be displayed.

At the SELECT PARAMETER prompt, key in the desired response from the displayed range of variables. Follow the desired variable by <ENTER>. Some variables may require more than one entry. The appropriate prompt for these selections is provided. Some selections, such as “Codes” can have more than one variable changed at the prompt. All changes to the variables should be keyed at the prompt prior to <ENTER>.

NOTES •

Both upper and lower case key entries are accepted.

•

The <Esc> key will always return the user to the main menu.

Compsee, Inc. TurboWedge-1199

25

Page 26

BEEP SEQUENCES • Hi beep = Emitted after each key response. Denoting that the key was accepted. • Hi/Lo beep = the number of key entries expected was exceeded, backspace will remove such entries. • Hi/Hi beep: denotes that the parameter selection is valid and is entered into non volatile memory. This will occur after completing a parameter sequence • Hi/Lo/Lo beep: denotes that the sequence was not valid and must be reentered. EXAMPLE General I: General II: Scanner Port: Codes Ind.:

Edit:

Beeper Volume 5 Mag Track 1&2 Postamble 0D Code 3of 9 min length 10 max length 10 ck digit on Code 11 off Input: 00A231Z507 Output: AZ<TAB>231507<ENTER>

For the following example all user operations will be in bold type. All On Screen Programming screen displays will be in normal type. After each key entry sequence a Hi/Hi beep should emit from the unit. Action: Action:

Power up the TurboWedge Advance to an input screen

Key:

<OSPM><Enter>

Screen:

MAIN MENU 1-TERMINAL 2-GENERAL 3-SCANNER 4-SERIAL 5-CODES 6-EDIT 7-STATUS 8-MISC 9-EXIT SELECT GROUP 2<Enter>

Key: Screen:

Key:

GENERAL I B0-DFLT B1-BEEP B2-IIH CK B3-KB TYP B4-ICH DLY B5-IFC DLY B6-FRN KBD B7-NUM PAD SELECT PARAM B1<Enter>

Screen: Key:

ENTER 0-7 5<Enter>

Compsee, Inc. TurboWedge-1199

GENERAL II C0-DFLT C1-MAG C2-BUFF C3-SOL RCD C4-SWCHS

26

Page 27

Screen:

Key: Screen:

Key: Screen:

Key: Screen:

Key: Screen:

Key:

Compsee, Inc. TurboWedge-1199

GENERAL I B0-DFLT B1-BEEP B2-IIH CK B3-KB TYP B4-ICH DLY B5-IFC DLY B6-FRN KBD B7-NUM PAD SELECT PARAM C 1<Enter>

GENERAL II C0-DFLT C1-MAG C2-BUFF C3-SOL RCD C4-SWCHS

ENTER 0=AUX 1=TK1 2=TK2 3=TK3 4=TK1&2 5=TK1&3 6=TK2&3 7=TK1&2&3 8=ANY TK 4<Enter> GENERAL I B0-DFLT B1-BEEP B2-IIH CK B3-KB TYP B4-ICH DLY B5-IFC DLY B6-FRN KBD B7-NUM PAD SELECT PARAM <Esc>

GENERAL II C0-DFLT C1-MAG C2-BUFF C3-SOL RCD C4-SWCHS

MAIN MENU 1-TERMINAL 2-GENERAL 3-SCANNER 4-SERIAL 5-CODES 6-EDIT 7-STATUS 8-MISC 9-EXIT SELECT GROUP 3<Enter> SCANNER D0-DFLT D1-PREAM D2-POSTAM D3-LSR RDN D4-FUN CDS D5-CODE ID D6-ATOSCN D7-MULSCN SELECT PARAM D2<Enter>

27

Page 28

Screen: Key:

ENTER 00-FE 0D<Enter>

Screen:

SCANNER D0-DFLT D1-PREAM D2-POSTAM D3-LSR RDN D4-FUN CDS D5-CODE ID D6-ATOSCN D7-MULSCN SELECT PARAM <Esc>

Key: Screen:

Key: Screen:

Key: Screen:

Key:

Compsee, Inc. TurboWedge-1199

(16 MAX)

MAIN MENU 1-TERMINAL 2-GENERAL 3-SCANNER 4-SERIAL 5-CODES 6-EDIT 7-STATUS 8-MISC 9-EXIT SELECT GROUP 5<Enter> CODE IND H0-DFLT H1-CODABAR H2-3OF9 H3-I 2OF5 H4-2OF5 H5-CODE 11 H6-CODE 93 H7-CODE128 H8-MSI PLESSEY SELECT PARAM H2<Enter>

CODE RET I0-DFLT I1-UPC I2-EAN

ENTER 1/0 ON/OFF A 00-64=MIN LEN B 00-64=MAX LEN C 1/0=S/S XMIT D 1/0=FULL ASCII E 1/0=CK DIGIT F 1/0=CK DIGIT XMIT G 1/0=APPEND A10B10E1<Enter>

28

Page 29

Screen:

Key: Screen:

Key: Screen:

Key: Screen:

CODE IND H0-DFLT H1-CODABAR H2-3OF9 H3-I 2OF5 H4-2OF5 H5-CODE 11 H6-CODE 93 H7-CODE128 H8-MSI PLESSEY SELECT PARAM H5<Enter>

CODE RET I0-DFLT I1-UPC I2-EAN

ENTER 1/0 ON/OFF A 00-64=MIN LEN B 00-64=MAX LEN C=1 CK DIGIT D=2 CK DIGIT 0<Enter> CODE IND H0-DFLT H1-CODABAR H2-3OF9 H3-I 2OF5 H4-2OF5 H5-CODE 11 H6-CODE 93 H7-CODE128 H8-MSI PLESSEY SELECT PARAM <Esc>

CODE RET I0-DFLT I1-UPC I2-EAN

Key:

MAIN MENU 1-TERMINAL 2-GENERAL 3-SCANNER 4-SERIAL 5-CODES 6-EDIT 7-STATUS 8-MISC 9-EXIT SELECT GROUP 6<Enter>

Screen: Key:

ENTER 01-15 EDIT NUM; 00 EXIT 01<Enter>

Screen:

ENTER 1=SCANNER 2=AUX 3=MAG 4=ALL 1<Enter>

Key:

Compsee, Inc. TurboWedge-1199

29

Page 30

Screen:

Key:

ENTER A=CODABAR B=CODE 3OF9 C=UPC-A D=EAN E=I 2OF5 F=2OF5 G=ALL/AUX/MAG H=CODE 11 I=CODE 93 J=CODE 128 2=PLESSEY B<Enter>

Screen: Key:

ENTER 00-64=INPUT RCD LENTGH 10<Enter>

Screen: Key:

ENTER 01-31=FLDS IN INPUT RCD 05<Enter>

Screen: Key:

ENTER 00-64=INPUT FLD LENGTH 02<Enter>

Screen: Key:

ENTER 00-7E=ASCII FUN CODE 1=MATCH 00<Enter>

Screen: Key:

ENTER 00-64=INPUT FLD LENGTH 01<Enter>

Screen: Key:

ENTER 00-7E=ASCII FUN CODE 1=MATCH 411<Enter>

Screen: Key:

ENTER 00-64=INPUT FLD LENGTH 03<Enter>

Screen: Key:

ENTER 00-7E=ASCII FUN CODE 1=MATCH 00<Enter>

Screen: Key:

ENTER 00-64=INPUT FLD LENGTH 01<Enter>

Screen: Key:

ENTER 00-7E=ASCII FUN CODE 1=MATCH 5A1<Enter>

Screen: Key:

ENTER 00-64=INPUT FLD LENGTH 03<Enter>

Screen: Key:

ENTER 00-7E=ASCII FUN CODE 1=MATCH 0D<Enter>

Screen: Key:

ENTER 00-15=ADDED FLDS 01<Enter>

Screen: Key:

ENTER 01-15=ADDED FLD LENGTH 01<Enter>

Screen: Key:

ENTER 00-7E=ADDED FLD DATA 0B<Enter>

Screen: Key:

ENTER 01-46=OUTPUT SEQUENCE 0204060305<Enter>

Compsee, Inc. TurboWedge-1199

30