Page 11
II.
INSTALLING THE READER - KEYBOARD WEDGE Installation of the reader should be completed by a person familiar with installing and connecting computer systems and cabling.
TurboWedge 1 1)
INSTALLATION a) b) c) d) e) f)
2)
TurboWedge 2
TURN OFF POWER TO THE TERMINAL TO WHICH THE READER WILL BE CONNECTED. Locate the "Y" interface cable and verify that it is the correct cable for the terminal being used. Plug the cable into the back end of the unit. Unplug the keyboard from the terminal and re-plug the keyboard into the leg (short leg) of the "Y" cable that mates with it. Plug the remaining leg (long leg) of the "Y" cable into the terminal where the keyboard was connected. Arrange the fully connected unit so that all cables run fully and smoothly.
CONNECTING THE SCANNING DEVICE Plug the scanning device into Port 1 (the 9 pin "D" connector) on the FRONT panel.
3)
CONNECTING AN RS 232 DEVICE If an auxiliary RS 232 input device is to be used, plug the 10 pin modular connector of the cable (specified at the time of order) into Port 2 of Models 1 or 2. The port is a 10 pin modular receptacle located on the FRONT panel of the unit. Connect the other end of the RS 232 cable into the output port of the RS 232 input device.
4)
CONNECTING A MAGNETIC STRIPE READER If a Magnetic Stripe Reader is to be used, plug the 10 pin modular connector of the magnetic stripe reader (specified at the time of order) into Port 2 of Model 1and Port 3 of Model 2. Both ports are 10 pin modular receptacle located on the FRONT panel of the unit. NOTE: Any changes or additions desired for the Magnetic Stripe output must be programmed via the EDIT Parameters.
5)
TERMINAL POWER UP SEQUENCE Turn ON the power to the terminal. After approximately 1 seconds the unit will beep twice. This delay is intentional and occurs so that the terminal - keyboard power on reset routines have time to complete.
Compsee, Inc. TurboWedge-1199
11
Page 12
6)
PROGRAMMING FOR TERMINAL TYPE IMPORTANT: If this is a first time installation, it is NECESSARY to program the unit for use with the connected terminal. • • •
Using the TERMINAL TYPE programming menu, scan the ENTER bar code symbol. Scan the two (2) digits on the BAR CODE CHART which correspond to the two (2) digit code listed for the specific terminal. Scan the EXIT bar code symbol.
NOTE: After the EXIT symbol has been scanned, the terminal type information is stored in nonvolatile memory and will not have to be programmed again unless the unit is to be connected to another terminal. 7)
PROGRAMMING FOR ADDITIONAL PARAMETERS Use the remaining programming sheets, i.e. GENERAL I, GENERAL II, SERIAL I, SERIAL II, SCANNER PORT, INDUSTRIAL CODES, RETAIL CODES, KEYBOARD REMAPPING and EDIT to complete the programming. DEFAULT:
Each sheet has default parameters associated with it which are indicated by asterisks "*" on the programming menus.
To assign these DEFAULT parameters, 1. scan the ENTER symbol 2. scan the DEFAULT symbol 3. scan the EXIT symbol If Default parameters are not desired, 1. scan the ENTER symbol 2. scan the desired parameter 3. scan the letter/digit combination listed on the programming sheet 4. scan EXIT After the EXIT symbol is scanned, the program information is stored in non-volatile memory and will not have to be programmed again unless changes are desired.
INSTALLATION IS NOW COMPLETE The above instructions are for programming the unit using the provided bar code menus. Other programming methods are defined in Section 4.
Compsee, Inc. TurboWedge-1199
12
Page 13
III.
INSTALLING THE READER - DUAL/SINGLE PORT RS 232 Installation of the reader should be completed by a person familiar with installing and connecting computer systems and cabling.
TurboWedge 1 1.
TurboWedge 2
INSTALLATION a) TURN OFF POWER TO THE TERMINAL TO WHICH THE READER WILL BE CONNECTED. b) Plug the cable housing into the back end of the unit. c) Unplug the host interface line from the terminal. Connect this line into the leg of the "Y" cable that mates with it. (Dual Port) d) Plug the remaining leg of the "Y" cable into the terminal where the host cable was connected. Arrange the fully connected unit so that all cables run fully and smoothly.
2.
CONNECTING THE SCANNING DEVICE Plug the scanning device into Port 1 (the 9 pin "D" connector) on the FRONT panel.
3.
CONNECTING AN RS 232 DEVICE If an auxiliary RS 232 input device is to be used, plug the 10 pin modular connector of the cable (specified at the time of order) into Port 2 of Models 1 & 2. The port is a 10 pin modular receptacle located on the FRONT panel of the unit. Connect the other end of the RS 232 cable into the output port of the RS 232 input device.
4.
CONNECTING A MAGNETIC STRIPE READER If a Magnetic Stripe Reader is to be used, plug the 10 pin modular connector of the magnetic stripe reader (specified at the time of order) into Port 2 of Model 1and Port 3 of Model 2. Both ports are 10 pin modular receptacle located on the FRONT panel of the unit. NOTE: Any changes or additions desired for the Magnetic Stripe output must be programmed via the EDIT Parameters.
5.
CONNECTING THE POWER SUPPLY & TERMINAL POWER UP SEQUENCE Plug the external power supply into the receptacle located on the back of the unit. Then plug the power supply into a power source. After approximately 1 seconds the unit will beep twice. This delay is intentional and occurs so that the terminal - keyboard power on reset routines have time to complete. Turn ON the power to the terminal.
Compsee, Inc. TurboWedge-1199
13
Page 14
6.
PROGRAMMING FOR SERIAL COMMUNICATIONS IMPORTANT: • •
If this is a first time installation, it is NECESSARY with the connected terminal.
to program the unit for use
Using the TERMINAL TYPE programming menu, scan the ENTER bar code symbol. Scan the 32 on the BAR CODE CHART which corresponds to the to the selection for Dual Port RS 232 communications. (31 = Single Port Scan the EXIT bar code symbol.
NOTE:
After the EXIT symbol has been scanned, the terminal type information is stored in nonvolatile memory and will not have to be programmed again unless the unit is to be connected to another terminal.
SERIAL II MENU PAGE Program the following parameters to match the setting for Terminal to Host Communications. • • • • 7.
Stop Bits Baud Rate Parity Word Length Dual / Single RS 232 Flow Control
PROGRAMMING FOR ADDITIONAL PARAMETERS Use the remaining programming sheets, i.e. GENERAL I, GENERAL II, SERIAL I, SERIAL II, SCANNER PORT, INDUSTRIAL CODES, RETAIL CODES, KEYBOARD REMAPPING and EDIT to complete the programming. DEFAULT:
Each sheet has default parameters associated with it which are indicated by asterisks "*" on the programming menus.
To assign these DEFAULT parameters, 4. scan the ENTER symbol 5. scan the DEFAULT symbol 6. scan the EXIT symbol If Default parameters are not desired, 5. scan the ENTER symbol 6. scan the desired parameter 7. scan the letter/digit combination listed on the programming sheet 8. scan EXIT After the EXIT symbol is scanned, the program information is stored in non-volatile memory and will not have to be programmed again unless changes are desired.
INSTALLATION IS NOW COMPLETE The above instructions are for programming the unit using the provided bar code menus. Other programming methods are defined in Section 4.
Compsee, Inc. TurboWedge-1199
14
Page 15
IV.
METHODS OF PROGRAMMING
The unit is pre-programmed with standard default parameters that allow you to use it without programming. For customization, the various programming methods allow for changing any of the parameters. Once the parameter is selected, it is stored in non-volatile memory, and will not change unless the unit is reprogrammed. IMPORTANT: terminal.
If this is a first time installation, it is NECESSARY to program the unit for use with the connected
DEFAULT ALL - Reference Program Mode Menu in the back of the manual. To default the unit, the "Default All Parameters" bar code must be read. This will issue a High-Low beep. Approximately 1 second after this two (2) High beeps will be issued signaling that the unit is now reset to factory defaults. Once Defaulted, the Terminal ID will be set to "01" and all parameters on all of the programming menus, including the edit menu, will reset to their factory setting. PROGRAM LOCK - Reference Program Mode Menu in the back of the manual. Once you have programmed and tested a unit and verified that the data input and output is correct, you can lock out all future programming by enabling the Program Lock Mode. This parameter is a toggle type sequence. To Enable: 1. 2.
3.
Scan the Program Lock label on the Program Mode Menu in the back of the manual. Using the Bar Code Menus scan a three (3) digit numeric code by individually scanning single digit bar codes using the Bar Code for Menus (digits column) in the back of the manual. Example: 479 Scan the Program Lock label on the Program Mode Menu in the back of the manual.
The unit is now locked from further programming. To unlock, follow the same sequence using the same code.
CAUTION Once the program is locked, the lock code used can unlock it. However, if the lock code is unknown, the only way to unlock it is to send it in for service. Contact Compsee Customer Support for details.
Compsee, Inc. TurboWedge-1199
15
Page 16
PROGRAMMING METHODS There are 7 different ways in which to program the units. These are: 1. 2. 3. 4. 1.
Bar Code Menu Bar Code Batch Serial Batch Cloning
5. 6. 7.
WinCape Symbology Validation On-Screen
BAR CODE MENU
This programming method makes use of a menu of individual bar codes. You will find the menus in the back of each manual. These menu pages, when used in conjunction with a bar code scanner allow you to program the unit by choosing a parameter and set a variable selection for the parameter. The Bar Code Menus provided with each unit consist of the following pages: A. Terminal Selection Menu B. General I Menu C. General II Menu D. Scanner Port Menu E. Serial I Menu F. Serial II Menu – Aux Port G. Serial II Menu - Host Port H. Codes - Industrial Menu I. Codes - Retail Menu J. Keyboard Remap K. Edit Menu L. Status Check Menu M. Parameter Selection Menu Bar Code The following beep sequences should be noted when programming the unit. 1 HIGH, 1 LOW = Good Programming Read 2 HIGH = Exit Programming - Good Read 1 HIGH, 2 LOW = Programming Error Out of Sequence Programming Label
Example 1:
1. 2. 3. Example 2:
1. 2. 3. 4. Compsee, Inc. TurboWedge-1199
Select Terminal Type (DEC VT 320 = Terminal Type 15) Using the TERMINAL TYPE programming menu, scan the ENTER bar code symbol. Using the Bar Code Chart, scan a 1, then a 5 under the digits column. Scan the EXIT bar code symbol. Select a Scanner Postamble “ABC” followed by the TAB key. (Codes 41,42,43,09) Using the SCANNER PORT programming menu, scan the ENTER bar code symbol. Scan the Postamble bar code Using the Bar Code Chart, scan a 4,1,4,2,4,3,0,9 using both the alpha and digits columns. Scan the EXIT bar code symbol. 16
Page 17
DEFAULT SELECTIONS 1)
ALL SELECTIONS To default back to the factory set parameters scan the DEFAULT ALL symbol on the Status Programming Menu. After the bar code is scanned, a high-low beep sequence will be emitted from the unit Note: DEFAULT ALL will delete all edits and remapping programmed.
2)
sequences that have been
PER MENU PAGE To default to the factory set parameters by menu page, scan: Enter - for the page parameters you wish to default Default Exit
Compsee, Inc. TurboWedge-1199
17
Page 18
2.
BAR CODE BATCH
This programming method combines multiple selections into one or more bar codes. Bar Code Batch strings are made up of Code 39 Full ASCII bar codes. The unit requires Code 39 Full ASCII enabled. As an example, instead of scanning 11 bar codes to select the following Postamble, only one bar code would be scanned Example 1: Bar Code Menu Method: Select a Scanner Postamble “ABC” followed by the TAB key (Codes 41,42,43,09) 1. 2. 3. 4.
Using the SCANNER PORT programming menu, scan the ENTER bar code symbol. Scan the Postamble bar code Using the Bar Code Chart, scan a 4,1,4,2,4,3,0,9 using both the alpha and digits columns. Scan the EXIT bar code symbol.
Example 1: Bar Code Batch Method: Select a Scanner Postamble “ABC” followed by the TAB key (Codes 41,42,43,09) 1.
Scan the following Code 3 of 9 bar code
PROGRAM CODES Program codes are defined on the bar code menu page where each selection is assigned an alphanumeric code. •
The first digit of each code represents the menu page. A = Terminal Selection F = Serial II Aux Port Selections B = General I Selections G = Serial II Host Port Selections C = General II Selections H = Code Selections - Industrial D = Scanner Port Selections I = Code Selections - Retail E = Serial I Selections J = Edit Selections
•
The second digit of each code represents a particular parameter on the page. Examples: B1 = General 1 Selections Beeper Volume H1 = Code Selections - Industrial Codabar D6 = Scanner Port AutoScan
Note:
An alpha followed by a numeric zero denotes the factory default for that entire assigned menu selections. (e.g. C0 = Default General II Selections).
Compsee, Inc. TurboWedge-1199
18
Page 19
•
The following alpha or numeric digits represent the selection from the bar code menu chart. Examples: B15 = General 1 Selections Beeper Volume Setting 5 H1A06 = Code Selections - Industrial Codabar Minimum Length 06 D608 = Scanner Port AutoScan Detect rate of 08 (800 milliseconds) C20 = General II Selections Buffering, Off Note:
The “ON/OFF” variable would be represented with numeric “1/0” 1 = ON 0 = OFF
START / STOP AND SELECTION SEPARATORS Start String = -(2 Dashes) End String = -(2 Dashes) Selection Separators = (1 Dash) Note:
Parameters from any given menu page, in any given order are allowed in a batch string.
BATCH STRINGS Long batch strings may be broken into smaller strings as (e.g. “-- First String --”, “-- Second String --”, “--Third String --” ). Note the following when creating multiple strings. Breaks in a batch string must be on menu selection boundaries, such as after the end of a variable selection and before the next menu selection. Edit batch strings must be programmed in the order of the variables, and in the case of a broken string, the strings must be entered in sequential order. Edit batch strings, or broken Edit batch strings that do not contain all necessary variables, will be terminated, without parameter changes, when the batch programming mode is terminated. ENTERING BATCH MODE PROGRAMMING Batch Mode Programming is entered whenever a Bar Code Batch string is received by the unit and terminated when a non-Batch Mode record is received. EXAMPLES •
Program Terminal ID to 01
Compsee, Inc. TurboWedge-1199
19
Page 20
• •
Program Beeper Volume to 3 Keyboard Type to Secondary (Caps Lock On)
• •
Program Terminal ID to 01 Scanner Postamble to 0D
•
Edit: Code 39 five digit bar code, match and remove first digit and add “CR”: Input = A1234 Output = 1234 “CR”
Note:
Prior to the first Edit the “J0” sequence must be received by the unit. After the last Edit entered add the “JC” sequence.
The batch string could be broken into three strings as follows:
Test Code = A1234
Compsee, Inc. TurboWedge-1199