Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 10

TurboWedge Installation and Operations Manual, pages 1 to 10

Pages 1 to 10 of 97

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Compsee Turbo-Wedge

Page 1

TurboWedge™ By

Manual #: 02CO429

Installation and Operations Manual

Part Number: Printed: Revision Level:

02CO429 12/99 TW1 = 1.06, TW2 = 1.05

Copyright by COMPSEE, INC.

Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Notes This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Compsee, Inc. TurboWedge-1199

1

Page 2

QUICK START The following Quick Start Installation procedure will handle 95% of the keyboard wedge installation. If your cabling and hook-up do not conform to the instructions below, please consult the Programming Manual. INSTALLATION 1. TURN OFF POWER TO THE TERMINAL TO WHICH THE READER WILL BE CONNECTED. 2. Locate the "Y" interface cable. Plug the 15 pin male "D" connector of the "Y" interface cable to the 15 pin female "D" connector located on the back panel of the unit. 3. Disconnect the keyboard cable from the keyboard port and plug it into the short leg of the "Y" cable. 4. Plug the long leg of the "Y" cable into the terminals keyboard port. 5. Plug in the scanning device. 6. If an external power supply is required, Plug it into the receptacle located on the back of the unit. Then plug the power supply into a power source. 7. Turn on the power to the terminal. 8. PROGRAM FOR TERMINAL TYPE IMPORTANT: If this is a first time installation, it is NECESSARY to program the unit for use with the connected terminal. Proceed as follows: • Using the TERMINAL TYPE programming menu (back of manual), scan the ENTER bar code symbol. • Scan the two (2) digits on the BAR CODE CHART which corresponds to the two (2) digit code listed for the specific terminal. • Scan the EXIT bar code symbol. 9. Scan the following bar code to verify communications to the terminal.

10. PROGRAMMING FOR ADDITIONAL PARAMETERS Use the remaining programming sheets, i.e. GENERAL I, GENERAL II, SERIAL I, SERIAL II, SCANNER PORT, INDUSTRIAL CODES, RETAIL CODES, EDIT and KEYBOARD REMAP to complete the programming. EXAMPLE: Return Key After Each Bar Code • Scanner Port Menu Scan: Enter Scan: Postamble • Bar Code Chart Scan: 0D • Scanner Port Menu Scan: Exit NOTE:

Each sheet has default parameters associated with it which are indicated by asterisks "*" on the programming menus. To assign these DEFAULT parameters, • scan the ENTER symbol • scan the DEFAULT symbol • scan the EXIT symbol

Compsee, Inc. TurboWedge-1199

2

Page 3

If Default parameters are not desired, • scan the ENTER symbol • scan the desired parameter • scan the letter/digit combination listed on the programming sheet • scan EXIT After the EXIT symbol is scanned, the program information is stored in non-volatile memory and will not have to be programmed again unless changes are desired.

Compsee, Inc. TurboWedge-1199

3

Page 4

TurboWedge 1 – Front View

TurboWedge 2 – Front View

TurboWedge 1 & 2 – Rear

KEYBOARD WEDGE INTERFACE

RS 232 DUAL PORT INTERFACE

Compsee, Inc. TurboWedge-1199

4

Page 5

Table of Contents I.

II.

III.

IV.

Introduction Output Options Keyboard Wedge RS 232 Input Options Bar Code Magnetic Stripe RS 232 Standard Specifications Dimensions Enclosure Power Supply Options Output Current Draw DC Voltage Environmental Electrical Electrostatic Discharge EMC Regulations Scanning Speed

8 8 8 9 9 9 9 9 9 10 10 10 10 10 10 10 10 10 10

Installing the Reader - Keyboard Wedge Installation Connecting the Scanning Device Connecting an RS 232 Device Connecting a Magnetic Stripe Reader Terminal Power Up Sequence Programming For Terminal Type Programming Additional Parameters

11 11 11 11 11 12 12

Installing the Reader - Dual Port RS 232 Installation Connecting the Scanning Device Connecting an RS 232 Device Connecting a Magnetic Stripe Reader Connecting a Power Supply Terminal Power Up Sequence Programming For Serial Communications Programming Additional Parameters

13 13 13 13 13 13 14 14

Methods of Programming Default All Program Lock Bar Code Menus Bar Code Batch Serial Batch Cloning WinCape Symbology Validation On-Screen

15 15 16 18 21 22 23 24 25

Compsee, Inc. TurboWedge-1199

5

Page 6

V.

VI.

VII.

VIII.

General Program Selections Interface Selection - Keyboard Wedge Interface Selection - Serial Output Beeper Volume Input Inhibit Keyboard Type Intercharacter Delay Interfunction Delay Numeric Keypad Magnetic Track Buffering Scale Solicit Record Switches Output Edited Records Only MSR Reverse Turbo Mode - HP, Wyse, PC/AT IBM PC/AT without Keyboard Laser with Marker Beam Laser with AutoSense Set Pause Time

32 32 32 33 33 33 33 33 34 34 34 35 35 35 35 36 36 36

Scanner Port Selections Preamble & Postamble Laser Redundancy Function Codes Code Identification AutoScan Multi Scan

37 38 38 38 38 38

Serial Input/Output Selections Preamble & Postamble Record Terminator Function Codes Baud Rate Parity Word Length Stop Bits Dual/Single Serial Flow Control Serial Input Protocol

39 39 39 40 40 40 41 41 41

Bar Code Selections Codabar Code 3 of 9 Interleaved 2 of 5 Industrial 2 of 5 Code 11 Code 93 Code 128 Plessey UPC EAN

42 42 42 42 42 42 43 43 43 43

Compsee, Inc. TurboWedge-1199

6

Page 7

IX. X.

XI.

Edit Programming Keyboard Remapping Single Character Replacement Swap Two Keys Swap Two ASCII Characters Multiple Key Function Code

44 61 62 63 63

Status Check General/Serial/Scanner Bar Code Configuration Edit Status Keyboard Remap Configuration

Appendices Interfaces Beep Sequences Key Code Charts Keyboard Function Records RS 232 Auxiliary Port Specifications RS 232 Data Transfer Definitions Input Inhibit Considerations Service and Repair Limited Warranty Terms Figure Listing Keyboard Interface - Wedge RS 232 Interface - Dual Port Front Panel - TurboWedge 1 & 2 Front Panel - TurboWedge 1 & 2 IBM 3180 - 1/2 Input Inhibit Installation IBM 3179-2 Input Inhibit Installation IBM 3196 Input Inhibit Installation IBM 3481/3486 Input Inhibit Installation

Compsee, Inc. TurboWedge-1199

67 68 69 70

71 73 74 79 81 83 90 95 96

7 7 9 9 73 74 75 76

7

Page 8

I. INTRODUCTION The decode/interface units are designed to be used with terminals provided by most of the major terminals manufacturers. •

Output Options Interfacing to the terminals can be either through the keyboard cabling or the RS 232 interface line to the host. Keyboard Interface: The unit plugs in easily between the keyboard and the terminal. Data passed through the unit appears to the terminal as if it had been keyed in by an operator.

RS 232 Serial Interface: If the terminal communicates to its host via RS 232 cabling and communications, the unit can be interfaced between the terminal and the host on the RS 232 cable. In most cases, data is passed through the unit to the host which in turn echoes the data to the terminal. The RS 232 Input port (Port 2 on Models 1 & 2) can also be used as an output port to send ASCII data on a single RS 232 line.

Both the keyboard and the in-line serial interfaces make it unnecessary by the user to implement any hardware or software changes in order to operate the bar code reader.

Compsee, Inc. TurboWedge-1199

8

Page 9

•

Input Options Bar Code Input • Port 1: Models 1 and 2 • Port 2: Model 2

Wand or Laser Emulation Wand Emulation

For bar code reading, a variety of input devices can be ordered that include light pens, slot readers, moving beam or fixed beam readers. With these devices, the unit is able to scan low, medium, and high density bar codes. The ability to autodiscriminate between most popular bar code symbologies is standard. Code 3 of 9 Interleaved 2 of 5 UPC/EAN Code 93 Plessey

Codabar Industrial 2 of 5 Code 128 Code 11

Magnetic Stripe Input • Port 2: Model 1 Tracks 1, 2 or 3* Single or Dual Track * Model 1Exceptions - Will not Support Track 3 on: Dec Terminals Terminals Monitoring Input Inhibit •

Port 3: Model 2

Tracks 1, 2 & 3 Single, Dual or Triple Track

RS 232 Input: • Port 2: Models 1 & 2 ASCII data from an external reader, a scale or a portable terminal can be transmitted through the RS 232 Input Port. Simple user programming guarantees that data passing through the unit will appear to the software as if it had been keyed in by the operator. The use of preamble/postamble, embedded keyboard function codes or keyboard function records allows for the operation of the terminal without manual entry from the keyboard. Changing code parameters or disabling certain codes is accomplished by either using the bar code programming menu found in the back of the manual or through one of the other optional programming methods described in Section 4. The units non-volatile memory stores the user program selections. •

Standard Specifications Dimensions • Length 3.65 inches (9.3 cm) • Width 3.75 inches (9.5 cm) • Height 1.10 inches (2.8 cm) • Weight 3.5 oz ( 99.2 g) - Approximate weight without cable

Compsee, Inc. TurboWedge-1199

9

Page 10

Enclosure • KJB flame retardant Power Supply Options • +5V to +14V supplied from the terminal or optional 9V power supply which may be required in some cases Output • +5VDC ± 10% to attached input device Current Draw • 70 mA typical DC Voltage • Power source shall meet the equipment requirements for reinforced insulation according to EN 60 950:1988 (SELV) Stromversorgung • 70 ma at 5 V • Gleichspannung soannungsquelle muss den lsolationsvorschriften EN 60 950/1988 entsprechen Environmental • Operating Temperature: +32° F to +122° F 0°C to 50°C • Storage Temperature: -77°F to 140°F -25°C to +60°C • Relative Humidity: 0% to 95% non-condensing Electrical • Keyboard Wedge Interface - Power is normally consumed from the terminal. No auxiliary power supply is required. Exceptions are noted in Appendix A. • RS 232 Interface - The auxiliary power supply is required. Electrostatic Discharge • 15 KV to any external surface EMC Regulations • FCC and CE Scanning Speed • Scans at 3 to 45 inches per second on standard density bar codes. Its speed range varies with code choice and density.

Compsee, Inc. TurboWedge-1199

10