The text of a manual · part 6 of 10
TurboWedge Installation and Operations Manual, pages 51 to 60
Pages 51 to 60 of 97
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Compsee Turbo-Wedge
Page 51
12) Specify the Field to be Added Using the ASCII Code Chart, indicate in Hexadecimal each character of the field to be added. Example: BAR CODE = 8 digits 42 41 52 20 43 4F 44 45 B A R Space C O D E The number of characters entered MUST equal the Added Field Length given in Item 11. The maximum number of characters per field is 15. Ignore this entry if there are NO Additional Fields. REPEAT ITEMS 11 AND 12 UNTIL ALL ADDITIONAL FIELDS ARE DEFINED. 13) Specify Output Record Sequence Indicate the order in which the fields should be output. If a field is NOT to be included in the output record, do not include it in the sequence. Field Numbering: Input Fields start at 01. Added Fields start with the number immediately following the last Input Field. Example: 6 Input Fields + 4 Added Fields For Output Sequencing, the Input Fields are numbered 01 - 06 and the Added Fields are numbered 07 - 10. 14) Scan EXIT EDIT PROGRAMMING REPEAT STEPS 1 - 14 FOR ALL INPUT RECORDS REQUIRING AN EDIT. NOTE: For each Edit, you must first Enter Edit Programming and then Exit defined. •
Edit Programming after each Edit is
PROGRAMMING CONSIDERATIONS - GENERAL 1.
It is strongly advised that prior to attempting any CAPE programming that Section 9 be read in its entirety and that a worksheet be filled out.
2.
Maximum number of Input Records that can be edited = 99, or until all memory allocated for edit programming is used.
3.
A beep sequence of 4 Highs and 4 Lows indicates that you have exceeded the memory space available
4.
Maximum number of Fields divisions per Input Record = 31.
5.
Maximum Input Record Length = 32. The exception to this would be input from a Magnetic Stripe Reader.
6.
Default = No Edits.
7.
Must always scan in "ENTER" before each Input Record Edit.
8.
Must always have a "01" Edit designated. Must always be the first edit entered.
9.
Must always answer all options on the parameter menu in sequential order.
10. Must enter a two (2) digit code where defined. Example: Input Length of 3 = 0 and 3, not just 3.
Compsee, Inc. TurboWedge-1199
51
Page 52
•
PROGRAMMING CONSIDERATIONS - "IF" CONDITIONS 1.
Match Code is only programmed when needed. If Match Code = ON Then "Input Field Length" = 01 Then "Function Code" = Hex Code to Match to
2.
If NO Additional Fields are desired Then "Additional Fields" = 00 (must be entered) Then "Additional Field Length" & "Additional Field Data" parameters do not have to be entered.
3.
If a Input Record is edited Then any Preambles and Postambles "WILL NOT" apply to the Input Record.
4.
If a Function code is not desired Then "Function Code" = 00 (Null)
5.
If any & all input is to be accepted Example: The unit is programmed to read only Code 128 from the Scanner Port, but varying lengths of Code 128 can be entered. Then "Input Record Length" = 00 (any length record) Then "Fields in Input Record" = 01 Then "Input Field Length" = 00
6.
If a Primary and Secondary output is being defined for an Input Record Then the Switch In Label must be the first edit "01". The Deactivate Switch Label must be the second edit "02". The Deactivate Switch Label is only used when you have entered Secondary output mode and then want to return to Primary output mode without reading a label designated for Secondary output.
Compsee, Inc. TurboWedge-1199
52
Page 53
•
DEFAULT SETTINGS To set default, scan the following sequence: 1) Enter Edit Selections 2) Default Edit Selections 3) Exit Edit Selections This sets the unit to "NO EDITS". If record edits have been programmed they will be deleted.
•
TURNING ON & OFF EDITS Once the unit is programmed for a series of edits, those edits can be turned On and Off by scanning the following sequence. If the edits are turned off, they will remain in memory until they are turned back on or the unit is defaulted. To Turn OFF - Scan the following 1) Enter Edit Selections 2) OFF 3) Exit Edit Selections To Turn On - Scan the following 1) Enter Edit Selections 2) ON 3) Exit Edit Selections
•
TURNING ON & OFF INDIVIDUAL EDITS One the unit is programmed for a series of edits, individual edits can be turned On and Off by scanning the following sequence. If an edit is turned off, it will remain in memory until it is turned back on or the unit is defaulted. Example = Turn Off or On Edit # 03 To Turn OFF Edit 03 - Scan the following 1) Enter Edit Selections 2) 03 3) D To Turn back ON Edit 03 - Scan the following 1) Enter Edit Selections 2) 03 3) E
•
ADDING AN EDIT Additional edits may be added at any time. New edit records must be given an Edit Number not already in use. Example: If Edit Numbers 01, 05 and 07 have already been defined, you could define a new edit with an Edit Number of 02, or 03, or 08, or 10, etc., as long as the original Edit Numbers are not used.
Compsee, Inc. TurboWedge-1199
53
Page 54
•
REDEFINING AN EDIT Once an edit is already in memory, it can be redefined. It must be remembered that whatever edit number you start redefining on, all subsequent edits, no matter what the order of entry, must be reentered. The Edits are stored by order of entry, not in numerical sequence (Exception, the first edit entered must be 01).
•
ERROR RECOVERY If you know you have made an error in the entry of an edit you can: 1) 2) 3)
•
Scan "Exit Edit Selections" and then reenter the edit from the beginning. If you exit a programming procedure before all options have been answered, that edit number will not be saved. Scan "OFF" until you get to a known correct entry. However, if you continue to scan "OFF" until you hear a series of beeps (1 High and 2 Low), you have reached the "Enter Edit Selections" bar code. If you reach this point, you must: Scan "Exit Edit Selections" Scan "Enter Edit Selections" Scan "ON" Scan "Exit Edit Selections" Restart your initial edit programming.
MAGNETIC INPUT CONSIDERATIONS Since Input Records from magnetic media can vary in length, special consideration must be given to it. EXACT RECORD LENGTH If the Record Length from the magnetic media is known (Example: Employee Badge), then the edit programming does not change. NOTE: All Sentinels and Field Separators must be taken into account in the editing process. VARIABLE RECORD LENGTH If the Record Length from the magnetic media is variable (Example: Credit Cards), then the edit programming must allow for it. Program "Input Record Length" = 00 for known variable input. The unit will use the input data from the left most position that has not been edited up until the next Field Separator or Stop Sentinel or Match Code. Mag Stripe Input - Recognizing Sentinels & Separators When “G” is programmed for the Symbology, the unit will use the Start/Stop Sentinels and the Field Separators to define fields. The unit assumes that the Field Separators and the Stop Sentinel (that are standard in mag stripe data) are the stopping point for a variable length field. Note that the Sentinels and Separators are still input as data that should be accounted for in the edit programming by indicating an Input Field Length of 01. Mag Stripe Input - Recognize End Sentinels Only When “E” is programmed for the Symbology, only the End Sentinel will be used to terminate the variable field length. Note that the Sentinels and Separators are still input as data that should be accounted for in the edit programming by indicating an Input Field Length of 01. A match character may also be defined.
Compsee, Inc. TurboWedge-1199
54
Page 55
If you are programming more than one magnetic input record, either have one of the records programmed for a variable input length, or use a Match Code Edit to distinguish between the tracks. If an area of the input data is known to be fixed in length, it can be specified as such. Example: The Expiration Date can be either a four digit field or two fields of two digits in length.
Compsee, Inc. TurboWedge-1199
55
Page 56
CARD OUTPUT SEQUENCE Track(s)
Output Sequence
1 2 3 1&2 1&3 2&3 1, 2 & 3
1 2 3 2, 1 3, 1 3, 2 3, 2, 1
CREDIT CARD INPUT TRACK 1 Definition Start Sentinel Format Code Primary Account No Field Separator Name Field Separator Expiration Date Additional Data Stop Sentinel
Data Input Field Length % 01 B 01 Numeric 00 (Variable) ^ 01 Alpha/Numeric 00 (Variable) ^ 01 YYMM 04 Numeric 00 (Variable) ? 01
TRACK 2: Definition Start Sentinel Primary Account No Field Separator Expiration Date Additional Data Stop Sentinel
Data Input Field Length ; 01 Numeric 00 (Variable) = 01 YYMM 04 Numeric 00 (Variable) ? 01
TRACK 3: Definition Start Sentinel Primary Account No Field Separator Use, Security & Additional Data Stop Sentinel
Compsee, Inc. TurboWedge-1199
Data Input Field Length ; 01 Numeric 00 (Variable) = 01 Numeric 00 (Variable) ? 01
56
Page 57
PROGRAMMING EXAMPLE # 3 Magnetic Stripe Input From Credit Card (Track Two) INPUT RECORD =
;1234567890123456=890810100000?
OUTPUT RECORD =
1234567890123456<ENTER>0889<ENTER>
ENTER EDIT PROGRAMMING Edit Number Port Symbology Input Record Length Fields In Input Record Field 1: Input Field Length Function Code Field 2: Input Field Length Function Code Field 3: Input Field Length Function Code Field 4: Input Field Length Function Code Field 5: Input Field Length Function Code Field 6: Input Field Length Function Code Field 7: Input Field Length Function Code Added Fields: Added Field Length Added Field Data Ignore Output Sequence EXIT EDIT PROGRAMMING
Compsee, Inc. TurboWedge-1199
01 3 (Magnetic) G (All) 00 (Variable) 07 01 (;) 00 (Null) 00 (Variable) 0D (Enter) 01 (=) 00 (Null) 02 (89) 0D (ENTER) 02 (08) 00 (Null) 00 (Variable) 00 (Null) 01 (?) 00 (Null) 00 Ignore 02, 05, 04
57
Page 58
PROGRAMMING EXAMPLE # 4 Primary and Secondary Output Formats: A Primary and Secondary Output Format actually defines two output formats for one input record. The second of the two output formats is activated by reading a "Switch Label". SWITCH LABEL: When programming for Primary and Secondary Output Records you must define a label that when read will activate the switching. The Switch label MUST be defined as EDIT "01". After indicating Edit #01, Scan "ON" to indicate that the Switch label is being defined. Then, use the Match Code identifiers to indicate the characters in the label that will be used for switching. Once switched, the unit will output the secondary record format on the next input record and then automatically switch back to primary output. Only one Switch Label may be designated. Do not specify an output sequence for this record edit. DEACTIVATE SWITCH LABEL: When programming for Primary and Secondary Output Records you must define a label that when read will deactivate the switching. The deactivate or void switch would be used to return to primary output. After indicating Edit #02, Scan "ON" to indicate that the Deactivate Switch label is being defined. Then, use the Match Code identifiers to indicate the characters in the label that will be used for switching. Only one Deactivate Switch Label may be designated. Do not specify an output sequence for this record edit. SECONDARY EDIT DEFINITIONS: When a Secondary Edit is defined for a record, Scan "ON" immediately following the Edit Number of the Secondary Record. This indicates that when a Switch Label is read that the unit will search for a Secondary Output based on the Input Record qualifiers.
Compsee, Inc. TurboWedge-1199
58
Page 59
SEQUENCE OF PROGRAMMING Notes:
"01" edit must always be the first edit. "01" Edit must indicate the Switch In Label “02" Edit must indicate the Deactivate Switch Label.
INPUT RECORD:
129392844668374500001295
PRIMARY OUTPUT RECORD:
1293<TAB>92844<TAB>6683745<TAB>00001295<ENTER>
SECONDARY OUTPUT RECORD: 1293<TAB>92844<TAB>6683745<TAB> SWITCH IN LABEL = DEACTIVATE SWITCH LABEL = A
X
ENTER EDIT PROGRAMMING BEFORE EACH EDIT Edit Number: Switch Label: Port: Symbology: Input Record Length: Fields In Input Record: F 1: Input Field Length: Function Code: 58 (X) Match Code: F 2: Input Field Length Function Code: F 3: Input Field Length: Function Code: F 4: Input Field Length: Function Code: Added Fields: Field Length: Field Data:
01 ON 1 B 01 01
02 ON 1 B 01 01
03
01 01 41 (A) 0B ON ON
04 0B
04
05 0B
05
0B
07 0B
07
0B
08 0D 00 Ignore Ignore
08
0D 00 Ignore Ignore
00 Ignore Ignore
1 B 24 04
04 ON 1 B 24 04
00 Ignore Ignore
Output Sequence:
EDIT 01 = IGNORE EDIT 02 = IGNORE EDIT 03 = 01, 02, 03, 04 EDIT 04 = 01, 02, 03 EXIT EDIT PROGRAMMING AFTER EACH EDIT
Compsee, Inc. TurboWedge-1199
59
Page 60
SWITCH IN LABEL
DEACTIVATE SWITCH
Compsee, Inc. TurboWedge-1199
60