Page 31
Networking your vision
CONSOLE (CLI) SETTING Various configuration and system parameter setting can be done via Console (CLI) commands using Microsoft Hyper Terminal Application or Telnet.
HYPER TERMINAL SETTING Connecting a computer with a built-in Hyper Terminal Application to the Cohu 9900 Series unit performs the definition of the various setup values. Turn-on the computer and define the Hyper Terminal application COM port setting values as follows (see Fig 4-1): ◦
Bits per second – 38400
◦
Data bit – None
◦
Stop bits – 1
◦
Flow control – None
Figure 4-1: Hyper Terminal Application COM Port setting Values
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 31 of 93
Page 32
Networking your vision
CONSOLE (CLI) SETTING Connect the computer to the Cohu 9900 Series unit via the units COM 3 (RS232 port), using the RS232 D9 to RJ45 cable supplied with the unit. When the computer has been connected to the Cohu 9900 Series unit and the Hyper Terminal application is active, reboot the Cohu 9900 Series unit (disconnect the power cable from the power source and then reconnect it or press the reset button). During the reboot process, press the space bar (see figure 4-2) in order to get “[VxWorks Boot]:” prompt (see figure 4-3).
Figure 4-2
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 32 of 93
Page 33
Networking your vision
Load Factory Default Configuration to NVRAM Type an upper case 'F' and press Enter. The system will update NVRAM with default parameters (see figure 4-3). NOTE: The IP address will set to defalt: 192.200.10.20
Figure 4-3
Communication Parameters Setting 1. Type a lower case 'c' and press Enter. Each time you press Enter button, you will get another parameter line. 2. Press Enter until you get the "inet on ethernet <e>' :" line. The factory default IP address is 192.200.10.20. Type your IP address and press Enter. This will change the factory default IP address to the address you entered. 3. Press Enter until you get the "gateway inet <g>' :" line. The factory default will be blank. If a unit should receive/transmit data via the router, type in "gateway inet" line the router IP address. If not, leave this field empty.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 33 of 93
Page 34
Networking your vision
4. Type Enter until you will get "other <O> :" line. 5. Wait until "[VxWorks Boot]:" prompt will appear after a few seconds (see Figure 4-4).
Figure 4-4
Flags Parameters Boot flags (f) parameters defined as following (See Figure 4-4):
Flags
Descriptions
0x0 0x01 0x02 0x04 0x08 0x20 0x40 0x80 0x100 0x1000 0x2000
Default Don't start SMMG Load local system symbols Don't autoboot Quick autoboot (no countdown) Disable login security Use bootp to get boot parameters Use tftp to get boot image Use proxy arp Flash erase Reduce Max Idle characters on COM1 (from 12 bytes to 2 bytes) Reduce Max Idle characters on COM2 (from 12 bytes to 2 bytes) Reduce Max Idle characters on COM3 (from 12 bytes to 2 bytes)
0x4000 0x8000
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 34 of 93
Page 35
Networking your vision
Real Time Clock (RTC) Setting 1. In order to setup the date and time, type upper case 'T' key. 2. Update date and time parameters until you get the "[VxWorks Boot]:" prompt (see figure 4-5).
Figure 4-5
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 35 of 93
Page 36
Networking your vision
Boot Parameters Setup Display In order to display the Boot parameters setup, type a lower case 'p'. The following parameters will display (see Figure 4-6):
Figure 4-6
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 36 of 93
Page 37
Networking your vision
Reset from CLI Press 'CTRL" "x" keys simultaneously. The unit will reset and boot up to application mode. Wait until you will get the "Manager at 0, addr 127.0.0.0 connected" message (see Figure 4-7).
Figure 4-7
POWER CONNECTION Connect the desktop power supply (supplied with the unit) to the Cohu 9900 Series unit, using the POWER connector. Connect the other cable to an AC power source. Verify that the ON LED (located on the front panel) is lit and that after several seconds the FLT LED goes out.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 37 of 93
Page 38
Networking your vision
CONNECTION TO NETWORK Connect one end of the communication cable (CAT5 direct cable) to the 10/100 connector on the front panel of the Cohu 9900 Series unit. Connect the other end of the communication cable to your local Ethernet network (SWITCH). Verify that the LNK LED is lit. NOTE: Make sure that the communication cables are wiring according to Ethernet Cable Color Coding Standard T-568A & T-568B.
CONFIGURATION SETTINGS Before the various devices have been attached to the Cohu 9900 Series unit, it is necessary to define all the initialization and setup values required for the basic operation of the Cohu 9900 Series unit. The parameters to be defined include details of the Cohu 9900 Series unit and some network parameters. The default manufacturer settings can be changed in order to configure the Cohu 9900 Series unit according to the site requirements. For network and configuration settings please use Cohu Configurator Application software. For more details on how to use and install Configurator software, please reference to Chapter 5 (Configurator).
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 38 of 93
Page 39
Networking your vision
NETWORK SETTING The Configurator Application software is used to define the network parameters of the Cohu 9900 Series unit. The following steps are required for setting the basic network parameters, such as an IP address, Network Mask and Default Gateway: 1. Connect PC with Configurator software and the 9900 unit to the network (Switch) 2. From the main window select ‘Unit’/‘Update Firmware’ menu.
Figure 4-8
3. In ‘Update Firmware’ window the user must first make sure the unit is properly connected to the network and then enter its IP Address.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 39 of 93
Page 40
Networking your vision
The factory IP address is 192.200.10.20.
Figure 4-9
4. In order to retrieve Setup.txt file, select status.txt in the Parameters files section. 5. Press the GET button and wait for the data to download via the FTP protocol to the local disk, and then press the EDIT button to display the data in a text editor where you can modify communication parameters.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 40 of 93