The text of a manual · part 5 of 10
Cohu 9900 Series IP Video Network Appliances for Surveillance Management: User Manual, pages 41 to 50
Pages 41 to 50 of 93
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Cohu 9905
Page 41
Networking your vision
6. Edit network parameters IP address, Subnet Mask and Default Gateway (if required), and finally Save and Exit the file. For more details about 'status.txt’ file, please reference Appendix B. 7. Press PUT to download your changes (status.txt file) back to the unit. 8. Wait for operation confirmation (see Figure 4-9).
SYSTEM CONFIGURATION SETTING & TESTING The Configure & Test process of the system includes the setup of all required parameters for the system components, such as video parameters (resolution, brightness, contrast, etc), audio parameters (volume), recording parameters, serial port connection parameters and video stream parameters (frame rate, bit rate). It also includes the parameters for adding connections between the different units (Camera to Monitor, Microphone to Speaker, Transparent Serial and I/O connection) The Configure & Test Process should be performed after completion of the System Building Process as described in Chapter 5 Configurator section, and after physically connecting the units to the network as well as connecting all relevant devices (for procedure details please reference to the 'Connecting Devices' section below). For Configuration and test procedure please reference to the Chapter 5 Configurator section, 'Configure and Test' paragraph.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 41 of 93
Page 42
Networking your vision
CONNECTING DEVICES CONNECTING VIDEO SOURCES One video source may be attached to the Cohu 9900 Series. In order to attach a video source, connect one end of a video coax RG59 or RG11 cable to the video output of the Camera. Connect the other end of the cable to one of the VIDEO IN connector, located on the unit front panel. The lit LED indicates that the camera has been selected from the attached cameras using the management Application software (Configurator, 99910400 or 9991-0900). NOTE: Pay attention to the maximum coax cable length as defined in the Specifications section.
CONNECTING THE MONITOR The monitor connection is usually made in the control room. It enables the viewing of video pictures taken by the remote camera. In order to attach an analog monitor to the Cohu 9900 Series model, connect one end of a video coax RG59 or RG11 cable to the video inputs of the monitor and the other end to the VIDEO OUT connector located on the front panel of the 9900 unit. The lit LED indicates the monitor has been selected to the camera side unit using the management Application software (Configurator, 9991-0400 or 9991-0900).
CONNECTING AUDIO DEVICES Connect a microphone to the AUDIO IN connector (located on the rear panel of the unit). Connect a speaker to the AUDIO OUT connector (located on the rear panel of the unit). NOTE: An intercom system may be used in place of a microphone and speaker.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 42 of 93
Page 43
Networking your vision
CONNECTING DEVICES TO RS232 AND RS485/422 PORTS Devices that transfer data, such as computers, VMS boards, camera control and other industrial control systems can be connected to the COM 1 or COM 2 ports. Connect the data device to the Cohu 9900 Series unit via the COM ports, according to the connectors mapping table.
CONNECTING DISCRETE INPUT/OUTPUT (DIO) DEVICES Alarm devices, such as sensors (temperature, light etc.), automatic gate opening controls and alarms can be connected to a Discrete Input/Output (DIO) connector. The DIO connector has two dry-contact input and two opto-isolated output ports. 1.
Connect the alarm device to the Cohu 9900 Series unit via the alarm or relay connector, as specified in the Specification section and according to the connector mapping table.
2.
For more details how to connect alarm devices, please reference to APPENDIX C, ALARM (Discrete I/O) Application Note.
ADVANCED CONFIGURATION Definition of advanced configuration settings can be carried out using the Configurator Update Firmware window. The Update Firmware window enables loading and editing of the unit’s configuration files (status.txt & taskman.ini files). The advanced configuration file, taskman.ini, is part of the Cohu 9900 Series application software. The file contains all the initialization and setup values required for the Cohu 9900 Series unit operation. The manufacturer default settings in the file can be changed in order to configure the Cohu 9900 Series unit according to the site requirements. The file is in ASCII format and can be modified using any text editor (NOTE PAD). The parameters defined in this file include the Cohu 9900 Series unit details (OSD - On Screen Display, address, etc.), devices connected to the unit inputs (camera or monitor, etc.), description of the devices, video format and some network parameters.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 43 of 93
Page 44
Networking your vision
For more detailed information about operating taskman.ini file, please refer to Appendix A.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 44 of 93
Page 45
Networking your vision
CHAPTER 5 9900 SERIES: OPERATION Operation of the unit entails connecting and controlling the devices on the Camera side of the Cohu 9900 Series unit, located on the remote side, with the device(s) connected to the unit’s Cohu 9900 Series monitor side (more than one unit) located in the Control Center(s). The association process (definition of relationships) between the devices can be done using one of the following applications: ◦
Configurator (partial management)
◦
9991-0900 GUI Console Management software (full management)
◦
9991-0400 Viewer (partial management)
◦
Customer application build on Cohu’s API (full management)
CONFIGURATOR The Configurator is the main tool for configuring, building and maintaining the system, as well as testing and adjusting the devices (cameras, monitors, audio, DIO) it contains. Therefore it serves as the basis for the operation of all entities. Without a proper installed System Configurator, all other applications: 9991-0400 Viewer, 9950 NVR and 9991-0900 Console will not run. It is therefore recommended that prior to installing any application, you first install and run the Configurator to setup the system. Once the system has been configured properly and tested, you may continue to install other applications. A typical installation consists of one or more geographical sites, each of which may contain various surveillance components (cameras, intercoms, monitors, PAS, VMS, sensors, relays, etc) and recording units (9950-xxxx). Every operator, either using or configuring the system, is assigned a User Login ID and Password, which he should use to access all 4 applications.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 45 of 93
Page 46
Networking your vision
Every User/Operator, defined by the System Configurator may be granted access rights to one or more sites defined in the installed system. Once a user has an access right to a specific site, he may access ALL devices and recorders defined for that site. A user may access more than one site, and more than one user may access a single site. General guideline for setting up and configuring a system: Define the devices in your system (Cameras, Monitors, Recorders, etc). Specify their IP addresses, types, names, etc. Test the units to make sure they are properly configured and installed. Adjust their parameters if needed. Define the sites by giving them unique names (and an optional description). Define the Recorders by giving them unique names, and specifying their location on the network (path to video files, and database) Add devices and recorders (defined in step one) to your sites. Define the users in your system by assigning each a unique Login ID and Password in addition to other optional details. Specify the sites each user may access. The system configuration data created in the previous steps is stored in a Database file called Config.mdb. All other applications must have access to that file (Network or Local), when they are launched for the first time, in order to be able to copy that file to their local path. From that point on the three applications: 9950-xxxx, 9991-0400 Viewer and 9991-0900 GUI Console are free to use the local imported copy of the configuration file. In case of changes in the configuration of the installed system, the applications can recopy the Configuration Database file (using the Configuration Refresh option). All applications store in the system registry the original location of the Config.mdb file (which is also where the Configurator application is located) as well as other details necessary for them to function properly. NOTE: Users should not directly modify the Config.mdb file and the system Registry entries.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 46 of 93
Page 47
Networking your vision
USING THE SYSTEM CONFIGURATOR In order to start the Configurator application, the application requires a user name and a password. The package is supplied with a default, ready-to-use user name ‘Administrator’, and password ‘Admin’ for the Administrators user level. The log-in dialog window appears when first launching the Configurator application.
Enter the default user and password names to gain access User = Administrator Password = Admin NOTE: All four applications in the Cohu 9990 Management Suite have the same Login Dialog Window in which the user should enter his User ID and Password. Upon successful log-in, the Configurators Main Menu Dialog Window will appear as shown below.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 47 of 93
Page 48
Networking your vision
The Configurator main dialog window includes the following menu and sub-menus:
Main Menu Dialog Window
UNITS SUBMENU: Selecting the Units menu item opens the below dialog window.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 48 of 93
Page 49
Networking your vision
-Add Allows the user to define the system units and devices, first select the unit type. A unit may be defined as one of the following types: 9905-2000C (May be listed as 9905-1000C) 9905-4000C (May be listed as 9905-2000C) 9905-8000
(May be listed as 9905-5000)
9905-2000M (May be listed as 9905-1000M) 9905-4000M (May be listed as 9905-2000M)
For PTZ cameras the User selects the corresponding PTZ Checkbox, PTZ Protocol and related serial port of the station. The user should allocate a significant and unique name to the unit, allocate the required IP address and select the type of unit. (listed above).
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 49 of 93
Page 50
Networking your vision
The interface in a graphical, tree like presentation, displays the list of defined entities. The User may add new units, remove or edit defined units by pressing the ADD or REMOVE buttons or by double-clicking an existing unit for editing.
Duplicate Instead of adding units manually in single steps, any defined station may be automatically duplicated (cloned) along with its devices. The user may mark any station from the unit’s tree (on the left side of the form), and press the duplicate button.
Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 50 of 93