Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 10

Cohu 9900 Series IP Video Network Appliances for Surveillance Management: User Manual, pages 21 to 30

Pages 21 to 30 of 93

The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Cohu 9905

Page 21

Networking your vision

Network Interface IEEE 802.3/802.3U 10/100Base-TX (with Auto-

RJ-45

Negotiation) Cable Type

CAT5 UTP

Cable Length

Max. 100 m.

Audio Interface Coding Algorithm

G.711, G.729A

Bit Rate

64kbps / 8kbps

Inputs

RCA headphone jack Voltage:

160mV RMS MAX

Input Gain:

Software adjustable in: 1dB steps from -30dB to +30dB

Impedance:

10kOhm, AC coupled

S/N ratio:

> 90dB @ full scale

Output

RCA headphone jack Full scale voltage output:

1V RMS

Output Gain:

Software adjustable in: 1dB steps from -30dB to +30dB

Minimum Load:

16Ω

S/N Ratio:

>90Db @ for full scale output

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 21 of 93

Page 22

Networking your vision

Serial Interface RS-232 & RS-485 (COM1 &

RJ-45

COM2) Serial Trunk Interface (optional) RS-232 (COM 3 Full Control),

RJ-45

Discrete Interface Inputs 2 Dry Contact Ports Discrete Interface Outputs Outputs:

Opto-Isolated Voltag Max 24VDC

Max Output Current Max Absolute Current

Max 90 mA Max 100 mA

Physical Dimensions Size (WxHxD)

19.5x2.8x14 cm (7.67”x1.1”x5.51”)

Weight

0.5 kgs

Power Supply Mains Connection Voltage Full Auto Range (+/- 10%)

100-220 VAC +/- 10%

Frequency

47 - 63Hz

Power Consumption: 9905-2xxx

7W Typical

9905-4xxx

9W Typical

Environmental Conditions Operating Temperature (Indoor)

+0° to 50°C (41° to 122°F)

Extended Range Temperature

-34° to 74°C (30° to 165°F)

(Indoor) Storage Temperature

-34° to 74°C (-34° to 165°F)

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 22 of 93

Page 23

Networking your vision

Operating Humidity

5% to 95% (Non-Condensing)

Certifications Safety

UL Listed CE MARK

Electromagnetic Interference (EMC)

FCC 47 CFR part 15 subpart B, Class A CE, Class A

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 23 of 93

Page 24

Networking your vision

CONNECTORS MAPPING TABLE 10/100 NETWORK RJ-45 CONNECTOR

Pin Number

Signal Name

1

TD+

2

TD-

3

RD+

4

Not Used

5

Not Used

6

RD-

7

Not Used

8

Not Used

Figure 3-1: RJ-45 Connectors – Pins Order

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 24 of 93

Page 25

Networking your vision

SERIAL RS232 (COM 1) & RS422 (COM 2) RJ-45 CONNECTOR

Pin

RS232

Description

Number (COM1) 1

RS485

Description

(COM2) Not Used

RX+

Differential Data (Half Duplex optional, TRX+)

2

Not Used

RX-

Differential Data (Half Duplex optional, TRX-)

3

GND

Signal Ground

GND

Signal Ground

4

TxD

Transmit Data

Not Used

5

RxD

Receive Data

Not Used

6

Not Used

GND

Signal Ground

7

Not Used

TX+

Differential Data

8

Not Used

TX-

Differential Data

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 25 of 93

Page 26

Networking your vision

RS485 JUMPER SETTING The following table describes the jumper setting for RS485/RS422 full and half duplex configuration as well as RS485/RS422 termination setup (see table 3-1). In order to change the jumpers, follow the steps below: 1. Remove power from the unit. 2. Remove all attached cables to the unit. 3. Remove cover. 4. The jumpers are located between the RS232/485 port and 10/100 port. 5. Change jumpers according to the Table 3-1. DUPLEX

RS232/485 RJ45 PINS ORDER

JUMPER

NOTES

1 – RS485 TRX+ 2 – RS485 TRXJ9 IS OPEN IF

3 – GND 4 – RS232 TX RS485 HALF DUPLEX 5 – RS232 RX

J9, J11, J12, J13 ARE

TERMINATION ISN'T

CLOSED.

REQUIRED

J10 IS OPEN

6 – GND 7 – RS485 TX+

NOT USED

8 – RS485 TX-

NOT USED

1 – RS485 RX+ 2 – RS485 RX3 – GND 4 – RS232 TX

J11, J12, J13 ARE OPEN.

5 – RS232 RX

J9 & J10 ARE CLOSED

RS485 FULL DUPLEX

J9 & J10 ARE OPEN IF TERMINATION ISN'T REQUIRED

6 – GND 7 – RS485 TX+ 8 – RS485 TX-

Table 3-1: RS485 Jumper Setting

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 26 of 93

Page 27

Networking your vision

SERIAL TRUNK RJ-45 CONNECTOR (COM 3)

Pin Number

Signal Name

Description

(for RS232 only) 1

RTS

Request to Send

2

DTR

Data Terminal Ready

3

GND

Signal Ground

4

TxD

Transmit Data

5

RxD

Receive Data

6

DCD

Data Carrier Detect

7

DSR

Data Set Ready

8

CTS

Clear to Send

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 27 of 93

Page 28

Networking your vision

ALARM INPUT BLOCK TERMINAL Pin Number

Signal Name

1

IN 1+

2

IN 1-

3

IN 2+

4

IN 2-

IN1

+

IN2

-

+

-

Figure 3-2: DIO Input Connector – Pins Order

RLEAY OUTPUT BLOCK TERMINAL Pin Number

Signal Name

1

OUT 1+

2

OUT 1-

3

OUT 2+

4

OUT 2-

OUT1

+

OUT2

-

+

-

Figure 3-2: DIO Output Connector – Pins Order

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 28 of 93

Page 29

Networking your vision

POWER MINI DIN CONNECTOR Pin Number

Signal Name

1

GND (+5V Return Pass)

2

+5V IN

3

GND (+5V Return Pass)

4

+5V IN

5

GND (+5V Return Pass)

6

+5V IN

Figure 3-3: Power Connector – Pins Order

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 29 of 93

Page 30

Networking your vision

CHAPTER 4 9900 SERIES: INSTALLATION AND CONFIGURATION INSTALLATION REQUIREMENTS Cohu 9900 Series units should be installed indoors, in a dry and clean environment. The location should allow easy access to the cable channels or ducts. Do not install the Cohu 9900 Series where it may be subjected to extreme vibrations, dust, or fumes, which may damage the unit. NOTE: Pay attention to operating environment requirements as defined in the Specifications section.

Check that the unit supplied includes the following: ◦

Cohu 9900 Series unit

◦

Desktop Power Supply with AC power cord

◦

RS232 D9 to RJ45 Configuration Cable. (One cable per 5 9900 units is supplied)

◦

CD containing Cohu 9900 Series Documentations, Configurator Application and update unit firmware.

◦

Mating terminal block for DIO attachment.

When installing the Cohu 9900 Series unit, leave enough space at the front and back of the unit to allow free air circulation. Clearance of at least 1 ft. (approx. 33 cm) should be provided behind the unit to allow for easy access of cables.

Cohu Electronics – Model 9910 Series Quick Start Manual (6x-1056) Page 30 of 93