Page 11

Genus™ G2 Users Manual Module Options The Genus G2 Terminal provides UPS, Modem and WiFi Module Options. UPS 2050-011

UPS Module. The 2050-011 module provides backup power to the Genus™ G2 terminal and integrated readers and communications options in the event of a main power failure and brownout conditions. Battery. The 2050-011 uses a 2.3Ah Sealed LeadAcid battery with a nominal voltage of 12V. The battery will attain full charge after 12 hours of recharge time.

Modem 2042-300

Modem Comm Module. The 2042-300 module provides communication level conversion from a standard Telco line to RS232 levels for Genus™ G2. 56K Baud Modem. The modem is a 56K baud Auto Answer/Auto Connect modem which connects via the RJ11 Telco Port (Modem Host). It features Data Mode v.92 (57600 BPS) and supports enhanced “AT” commands.

WiFi 3046-101

Revision –

WiFi Comm Module. The 3046-101 communications module provides LAN and Internet connectivity with the standard Ethernet interface to applications. The module is interoperable with industry standard 802.11 LAN and Internet connectivity and provides advanced security standards such as WEP and WPA. It provides a complete, reliable transparent wireless connection between a G2 Terminal and a network host via an RF access point.

6-15-06

10

Page 12

Genus™ G2 Users Manual

Installation The installation process proceeds with the bulleted items below. All installation steps are discussed in the Installation Guide for Genus G2 (3000-IG-0001), however, follow only those that apply to your installation requirements. • • • • • • • • • • • •

Revision –

Wall Mount Installation & Recommended Height Grounding the G1 Terminal Wand / Scanner and Ethernet Connections Serial Aux Port Connection Digital Input Connection Digital Output Connection Power and UPS Connections Modules WiFi Antenna WiFi Module Connections Modem Module Connections Close & lock the Terminal and Store the Key

6-15-06

11

Page 13

Genus™ G2 Users Manual

Power Up The several displays with the following messages appear in sequence during the normal G2 Terminal power-up process. In addition, during power-up, the Genus G2 terminal also executes an internal firmware test.

Genus Loader Display Genus Loader will display with program and version numbers at the top of the screen. Followed by company name Control Module, Inc. 2004 Followed by “Loading Genus” and the following prompts; Entering LOADER SETUP Press Enter to continue Any other key to exit setup

Power-On Diagnostic Display Genus G2 will display with program and version numbers at the top of the screen. Followed by company name Control Module, Inc. 2004 Initializing Network displays with current IP of the terminal on the network IP:192.168.000.078 Initializing Flash Initializing File System Initializing Telnet Server Initializing TFTP Server Initializing RTC Initializing System Files Starting VM

Revision –

6-15-06

12

Page 14

Genus™ G2 Users Manual

Online Mode Following installation and power-up, the terminal will reach online mode at a screen that has been defined by the user. The terminal is now ready to communicate to the host system. The G2 Terminal is shipped with a basic test and reader setup application.

At this point the G2 Terminal has completed the boot process and transitions to a Java application that begins its functionality and data collection as defined by the user. If no user defined program has been loaded the terminal will display the CMI reader setup application.

Refer to Loading a Customer Defined Java Application in the Reference section of this document.

Revision –

6-15-06

13

Page 15

Genus™ G2 Users Manual

Offline Mode The Genus™ G2 terminal offline mode is utilized for initial setup and when any of the following options require a change: communications, readers, security, time/date, terminal maintenance and terminal administration. Offline Mode is accomplished by moving the switch located on the backplate of the terminal to the left position prior to power-up. If the switch is moved while the device is powered up the terminal will reset and enter Offline Mode. Note: If a transaction build is in process when the terminal is switched between modes this data will be lost. When no setup changes are required the switch position is to the right for Online.

Revision –

6-15-06

14

Page 16

Genus™ G2 Users Manual

Entering Offline Offline Mode for the G2 Terminal Setup Mode is entered through power-up as the Terminal initializes. The normal power up displays will occur until the ‘Starting:Setup’ displays message appears. Starting:Setup displays as a separate display prior to Terminal Information At this point the terminal stops and waits at the Terminal Information prompt, for keypad entry, as shown below, unless a PIN number has been setup then the terminal will request a PIN.

Note: Enter PIN prompt will only appear if PIN number has been setup in “Setup PIN” from main menu during a previous offline session.

Programmable Function Keys

Numeric keypad Used to setup Terminal Parameters

Revision –

Direction keys allow user to scroll through menus

6-15-06

Clear and Enter keys are display specific.

15

Page 17

Genus™ G2 Users Manual Menu Options located at the bottom of the display in Offline Mode TERMINAL INFORMATION is the first display reached as the Main screen when powered up into Offline Mode. This provides basic terminal hardware information.

Menu options include Main PIN Net Telnet Time Reader Maint TAdmin DUN

Main Terminal Information screen Security PIN Network Setup, includes option for WiFi Telnet port settings Time, Format, Time Zone settings Reader setup Maintenance Terminal Administration Dial-Up Network settings

Active keypad in offline mode The keypad is the users interface used to set terminal parameters and input data. Key activity works differently depending on the current display parameters. Left and Right Arrows Tab Delete (DEL), Backspace (BS) UP and Down Arrows Clear

Advance through menu selections located at the bottom of the display Advances through all parameters displayed, and returns to the menu selections located at the bottom of the display Edit at cursor location Scroll through available options at parameter location Will suspend entry and return to a previous display.

The following User Operational Display pages provide descriptions, additional information, and key activity for each menu option

Revision –

6-15-06

16

Page 18

Genus™ G2 Users Manual

User Operational Displays SETUP PIN Personal Identification Number (PIN) is used for security to prevent unauthorized entry into the setup mode.

1.

From the options at the bottom of the display press

2.

Press

3.

Use the numeric keypad to enter PIN.

to advance to and highlight PIN .

to highlight PIN field.

PIN field accepts <= (less than or equal to) 20 characters and is masked. 4.

Use

(backspace) or key as needed to delete part of field or to erase the entire field. Note: Step 5 must be used to accept the erased PIN field. Apply

5.

Use to highlight

6.

Use to return to the Main Menu at the bottom of the screen.

Revision – and press

6-15-06 to save settings.

17

Page 19

Genus™ G2 Users Manual NETWORK SETUP The Network Setup provides the ability to configure the Terminal’s network parameters, including DHCP, IP address, gateway, subnet mask, DNS servers, and telnet menu.

1. From the options at the bottom of the display press 2. Press to advance to and highlight Net .

to advance to and highlight the enable DHCP field.

Enable DHCP Turns on the terminal’s ability to obtain an IP address automatically from a DHCP server on the local network. 3. Press to check for enable or uncheck for disable DHCP.

4. If DHCP is not enabled, use to advance through the remainder of the Network setup parameters. If DHCP is enabled go to step 8. 5. Use the 6. Use the arrow keys for cursor position in the network parameter octets. arrow keys and numeric keypad to change settings for IP, Gateway,

Primary DNS and Secondary DNS. Terminal IP Used to specify a static IP address. Subnet Mask Used to specify a subnet mask for the terminal. Gateway IP Used to specify a gateway address for the terminal. This entry is optional if the terminal does not need to communicate with devices outside the immediate subnet. Primary DNS Used to specify a primary Domain Name Server (DNS). This entry is optional if the terminal does not need access to DNS services. Secondary DNS Used to specify a secondary Domain Name Server (DNS). This entry is optional if the terminal does not need access to DNS services.

Revision –

6-15-06

18

Page 20

Genus™ G2 Users Manual 7. Use arrow keys to change Subnet. Apply

8. Use to highlight and press to save settings.

9. Use to return to the Main Menu at the bottom of the screen.

The WiFi settings and information are also accessed on this display. WiFi information provides a resource for firmware and version releases and Link connectivity status.

For more information on the WiFi installation and setup refer to the Genus WiFi Module Installation section in this document.

Revision –

6-15-06