LLL, Veon Trot MODULE INC.

Genus™ G2 Users Manual

Page 2

Genus™ G2 Users Manual

Table of Contents Declarations .............................................................................................................................................. 2 Introduction............................................................................................................................................... 3 Genus™ G2 Terminal............................................................................................................................... 4 The User Interface .................................................................................................................................... 4 Terminal Features ..................................................................................................................................... 5 Terminal Hardware................................................................................................................................... 6 Terminal Connections............................................................................................................................... 8 Installation .............................................................................................................................................. 11 Power Up ................................................................................................................................................ 12 Online Mode ........................................................................................................................................... 13 Offline Mode .......................................................................................................................................... 14 Entering Offline ...................................................................................................................................... 15 User Operational Displays...................................................................................................................... 17 Genus™ WiFi Module Installation ........................................................................................................ 35 Genus™ WiFi Configuration/Setup ...................................................................................................... 40 Troubleshooting Genus™ WiFi Issues................................................................................................... 47 Troubleshooting Terminal Issues ........................................................................................................... 50 Reference ................................................................................................................................................ 52 Steps to Re-Program Genus Firmware: .............................................................................................. 52 Loading A Customer Defined Java Application..................................................................................... 53 Programming Table (Code 39) ............................................................................................................... 54 Service & Technical Support.................................................................................................................. 56

Disclaimer No part of this publication may be reproduced, or transmitted in any form or by any means without the written permission of Control Module, Inc. The information described by this publication is specifically intended for use by customers and resellers of Control Module Data Collection products and data collection systems and only for use with Control Module Data Collection products and data collection systems. The information in this manual is subject to change without notice and does not represent a commitment on the part on Control Module, Inc.

Revision –

6-15-06

1

Page 3

Genus™ G2 Users Manual

Declarations Control Module, Inc. Model: Genus™ G2 Serial: 3000

FCC Compliance The Control Module Model Genus™ G2 Time and Attendance Terminal conforms to the requirements of FCC PART 15, SUBPART B, CLASS A, 2004 for radiated and conducted emissions without modifications.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.

Revision –

6-15-06

2

Page 4

Genus™ G2 Users Manual

Introduction Welcome to Control Module’s Genus™ G2 Data Collection Terminal. The “Genius of Genus” is that it offers an intelligent Java programming language and enables companies – for the first time – to realize the maximum potential of their workforce management terminals, by using them as a powerful interface to connect highly customized applications and the databases that fuel them. The Genus™ open and modular platform is designed to provide fast, accurate, and reliable data collection for any industrial application. The Genus™ Terminal is ideal for time and attendance, workforce management, employee self-service, shop floor data collection, and access control. Genus™ is the intelligent and affordable decision for any organization. Congratulations on your purchase!

Revision –

6-15-06

3

Page 5

Genus™ G2 Users Manual

Genus™ G2 Terminal Terminal features are labeled in the picture below for reference. Descriptions of user interface, terminal features, terminal hardware and connections follow. Terminal Front

Invalid and Valid LED Card Read Indication

320X240 Backlit Monochrome Graphics Display End Bell designed for Barcode or Magnetic slot readers and/or Biometric Fingerprint Readers

End Bell designed for Proximity or Smartcard readers Reader 1

Reader 0 Tactile Feedback keypad includes user programmable function keys, numeric keypad, direction keys and parameter specific function keys. Softkeys align with software screen prompts

The User Interface The user interface offers options for data entry into the Genus G2 terminal through the 36-key ATM style membrane keypad, softkey, function, navigation and user programmable function keys and/or internal or external card readers. User output is via a 320X240 backlit Monochrome graphic LCD display. The terminal also has the capability to produce multiple sound tones to help guide the user.

Revision –

6-15-06

4

Page 6

Genus™ G2 Users Manual

Terminal Features Memory Configuration The Terminal is equipped with 32 MB of dynamic memory, 2 MB of non-volatile memory for data retention, and 40 MB of Flash memory for program storage. Programmability The Terminal is designed to be a Java-capable embedded data collection platform. Users may create, load, and execute J2ME Personal Profile 1.1 compliant applications that utilize existing OEM classes for display, keyboard, biometric, barcode, Magnetic, Proximity, Mifare, iClass, and DI/DO inputs and outputs. A software development kit (SDK) is available separately that provides development documentation, development support, and samples for the use of the OEM classes. Digital I/O The Terminal provides program control of integrated Digital Outputs for relay control, two (2) Digital Inputs, and includes a Tamper sense. Host Interface The Terminal comes with a dedicated Ethernet port for connection to 10/100 Ethernet networks. DHCP or static IP address configuration is supported. Display The Terminal is equipped with a 320 x 240 backlit Monochrome graphic LCD display. The full alphanumeric character set and graphics are supported. LED back-lighting provides viewing in low light conditions. Keypad The Terminal is equipped with a 36-key ATM style tactile response membrane keypad. The keys are divided into four groups; numbers, functions, navigation, and programmable keys. Keys positioned next to the display align with softkeys for ease of use. Power The configuration uses a 20 VDC 1 amp power pack to power the terminal. The power pack is UL listed and CSA certified. Audio Annunciator This is programmable with variable tone and duration capability.

Revision –

6-15-06

5

Page 7

Genus™ G2 Users Manual

Terminal Hardware Keypad – with local buffering 10 Numeric Keys, (0 through 9) 8 Function Keys (F1 through F8) Clear and Enter Keys Navigation Keys for cursor position and network parameters, alpha characters and special symbols. 8 Softkey aligned keys 4 Parameter Edit keys, Delete, Select, Backspace and Tab Display 320 x 240 Backlit Monochrome Graphics Display Media Readers 2 Internal reader ports, 1 External reader port, 1 Barcode wand port Magnetic Track 1 and 2 Barcode Code 39 and code 39 full ASCII, Interleaved 2of5, Code 128 Proximity allows up to a 99 bit badge (HID, Motorola) Smartcard (Mifare, iClass) Biometrics (Fingerprint) Beeper Variable duration monotone beep Variable duration warble beep Emit a series of beeps Host Interface RS232 10/100 Ethernet Modem via serial port (PPP) WiFi option External Control Relay Output - 30VDC @ 1A LED Two Status (red, green) Power Requirements 20 -30VDC, 3W Environmental Operating Storage Humidity Revision –

0°to 50°C (32° to 122°F) -40° to 66°C (-40° to 151°F) 0 to 90 % non-condensing 6-15-06

6

Page 8

Genus™ G2 Users Manual File System Specification The Terminal provides file systems on different hardware devices. Instead of using the common alphabet notation for file system devices ( ‘A:’, ‘C:’ ), the Genus terminal identifies the file storage devices as: Storage Device ‘\flashdisk’

‘\ramdisk’

‘\scratchdisk’

Memory size

Location

40 Mbytes

Low write, frequent read. Used for firmware, user applications, and application data.

2 Mbytes

High read/write usage. Data is preserved through power loss. Often used for transaction (punch) storage

5 Mbytes

High read/write usage. Temporary file storage. Not preserved through power outage

Digital Output (DO Relay Configuration) The relay port brings out the three relay connections (common, normally open, normally closed) plus ground. The common can optionally be connected to an internal current source, VUNREG (nominally, 12 volts at 100mA - over-current protected). The internal current source is useful when driving external buzzers, lamps, low current, low voltage devices or a larger external relay, since it requires no external power source. The Digital Output configuration design supports the option for both sourcing and nonsourcing DO. The DO is a Form C contact relay rated for 1 amp @ 30V AC/DC. Relay Port - Internal Power

Revision –

Pin

Function

1

Normally open contact

2

Common contact

3

Normally closed contact

4

Ground

5

VUNREG

6

Ground

7 - 12

DI Pins, See Terminal Connections

6-15-06

7

Page 9

Genus™ G2 Users Manual

Terminal Connections Terminal Back

Ethernet Port The Ethernet port supports the 10/100BASE-T Connector: 8 position RJ45. Pinouts: network connections 1 = Receive + 2 = Receive – 3 = Transmit + 4 = Input Power

5 = Input Power 6 = Transmit – 7 = GND 8 = GND

Serial Aux Port The Serial Aux port provides a serial connection Connector: 8 position RJ45. to interface to serial peripheral devices or for Pinouts: 1 = DCD modem communications. Default for pin-6 is 2 = RXD +12V power. 3 = TXD 4 = DTR

5 = GND 6 = +12V/DSR 7 = RTS 8 = CTS

Wand / Scanner Port The wand port maintains the standard CMI Connector 6 position RJ11 Pinouts: pinouts with the RJ11 connector. 1 = Shield 4 = N/C(No Connection) 2 = Ground 5 = Data 3 = +5 VDC 6 = Vunreg

Revision –

6-15-06

8

Page 10

Genus™ G2 Users Manual Digital Input / Output The digital input with tamper switch is included Connector 12 position Terminal Block with this terminal configuration. This option Pinouts: 1 = Normally Open (N.O.) detects attempts to interfere with normal 2 = Common (C) operation of the terminal. A pluggable connector 3 = Normally Closed (N.C.) is supplied with the terminal. The Digital Output 4 = Ground configuration design supports the option for both 5 = Vunreg sourcing and non-sourcing DO. The DO is a 6 = Ground Form C contact relay rated for 1 amp @ 30V 7 = +12 VDC AC/DC. The DO can be used to control or 8 = DI 1 monitor doors, bells, and alarms. 9 = DI 2 10 = Open Collector (OC1) 11 = Open Collector (OC2) 12 = Tamper External Reader Port An external port is provided for external reader connection. The port provides two digital inputs, one open collector and access to one RS232 serial port. Power to the external readers is also provided through this port.

Power Port Power is supplied to the terminal via a standard 5.5 mm (2.5 mm ID) Barrel Jack on the backplate of the terminal.

UPS (Uninterruptible Power Supply) An optional UPS is available to power the terminal in the event of a main power failure or brownout conditions.

Revision –

Connector 9 position Terminal Block Pinouts: 1 = Data 6 = GND 2 = Card Pres 7 = +12 VDC 3 = Clock 8 = RXD / 232 4 = OC2 9 = TXD / 232 5 = VDD Connector 5.5 mm (2.5 mm ID) Barrel Jack Pinouts: 1 = +20V to 30VDC 2 = Power Ground

Connector 7-Pin KK100

6-15-06

The UPS is shipped with a removable cable that plugs into the UPS connection port on the backplate of the G2 Terminal.