Page 21
Genus™ G2 Users Manual TELNET SETUP
1. From the options at the bottom of the display press 2. Press to advance to and highlight Telnet .
to advance to and highlight enable Telnet.
Enable Telnet Enables the telnet interface to the terminal. 3. Press to check for enable or uncheck for disable Telnet.
Note: If Telnet is disabled, 4. Press skips to the
Apply button to highlight Port field.
5. Use the numeric keypad to enter port number. Telnet Port Used to select a port to listen on for telnet configuration. 6. Press to highlight Password field.
7. Use the numeric keypad to enter password. Telnet Password Sets up a password for the telnet configuration. Note: This PIN password differs from the Offline mode PIN. Password field accepts <= (less than or equal to) 20 characters and is masked.
Revision –
6-15-06
20
Page 22
Genus™ G2 Users Manual 8. Use
(backspace) or key as needed to delete part of field or to erase the entire field. Note: Step 9 must be used to accept the erased Password field. 9. Use 10. Use to highlight
Apply and press to save settings.
to return to the Main Menu at the bottom of the screen.
Note: The Terminal will need to be restarted for Telnet changes to take effect. To restart the terminal If done with setup in offline mode, ensure there is power to the terminal and simply switch the offline/online switch to online, which will reboot the terminal.
Revision –
6-15-06
21
Page 23
Genus™ G2 Users Manual TIME SETUP
Time 1. From the options at the bottom of the display press 2. Press to advance to and highlight Time .
to highlight hour field (Time is set to a 24 hour clock).
3. Use the
(backspace) key twice to delete the hour and enter in new hour (HH) using the numeric keypad. 4. Press 5. Use the to highlight minute field. (backspace) key twice to delete the minutes and enter in new minutes (MM)
using the numeric keypad.
Date- Month 6. Press to highlight Date field.
7. Press to enter calendar.
8. Press to highlight backward or forward arrows for month direction, at the top of the screen. 9. Press
Revision – to move between the months.
6-15-06
22
Page 24
Genus™ G2 Users Manual
Date- Day 10. When in correct Month, Press or to advance to and highlight new date. 11. Press to accept the highlighted day date.
Date- Year The year can be edited in the date field, however if the slash separator is deleted by mistake return to step 10 to recover the date format.
12. While in the date field, use to delete and use the numeric keypad to change the year.
Time Zone 13. Press to highlight Time Zone field.
14. Press to enter Time Zone option list.
15. Use the arrows or to highlight an appropriate Time Zone from the option list. 16. Pressing exits from the time zone option list and returns to the Time Zone field. Apply
17. Use to highlight and press to save settings.
18. Use to return to the Main Menu at the bottom of the screen
Note: The Terminal will need to be restarted for the Time Zone change to take effect. To restart the terminal If done with setup in offline mode, ensure there is power to the terminal and simply switch the offline/online switch to online, which will reboot the terminal.
Revision –
6-15-06
23
Page 25
Genus™ G2 Users Manual READER SETUP
1. From the options at the bottom of the display press 2. Press 3. Use to advance to and highlight Reader.
to highlight active field for Reader 0, Reader 1 or Reader 2. to select type of reader (Barcode, Proximity/Wiegand, Magnetic, or None).
Reader 0 corresponds to the internal connection for Barcode or Magnetic readers located on the right side of the G2 Terminal when looking at the Terminal front. Reader 1 corresponds to the internal connection for Proximity or Smartcard readers located on the left side of the G2 Terminal when looking at the Terminal front. Reader 2 corresponds to the external Wand/Scanner connection located on the terminal backplate. Note: Biometric reader configuration is handled separately after the barcode section. 4. Press to configure reader. The following screen will appear for Barcode.
The box to the right of the first format will be highlighted.
Revision –
6-15-06
24
Page 26
Genus™ G2 Users Manual 5. Press to go to a list of barcode formats.
6. Press to highlight a barcode format.
Barcode Format options include None
Definitions
NO CODE CODE 39 NO CHECK
Standard Set, no check digit
CODE 39 CHECK NO TRANS
Standard set, check digit computed but not transmitted
CODE 39 CHECK TRANS
Standard set, check digit computed and transmitted
CODE 39 ASCII NO CHECK
Full ASCII, no check digit
CODE 39 ASCII CHECK NOT TRANS
Full ASCII, check digit computed but not transmitted
CODE 39 ASCII CHECK TRANS
Full ASCII, check digit computed and transmitted
I2OF5 NO CHECK
No check digit
I2OF5 CHECK NOT TRANS
Check digit computed but not transmitted
I2OF5 CHECK TRANS
Check digit computed and transmitted
CODE 128 NO CHECK
No check digit
CODE 128 CHECK NOT TRANS
Check digit computed but not transmitted
CODE 128 CHECK TRANS
Check digit computed and transmitted
7. Press either 8. Press 9. Press or to save and return to the previous Barcode Setup screen.
to highlight Length Qualifier field. to highlight a Length Qualifier.
Length Qualifier options include = (equal) or <= (less than or equal). 10. Press to highlight the Length field.
The Terminal accepts up to 32 in the length field, 32 being the total number of characters. 11. Use 12. Press to delete field and use the numeric keypad to enter a new value. to scroll through the remainder of the fields to select up to 5 barcode formats to test.
Revision –
6-15-06
25
Page 27
Genus™ G2 Users Manual 13. To cancel changes press 14. Press to Cancel and return to the Main Reader Setup screen.
15. To accept changes press 16. Press to advance to and highlight Cancel .
to advance to and highlight Apply .
to Apply and return to the Main Reader Setup screen.
17. On the Main Reader Setup screen (0, 1, 2) Press and press 18. Press
Revision – to advance and highlight Apply to save settings. to return to Main Menu at the bottom of the screen.
6-15-06
26
Page 28
Genus™ G2 Users Manual BIOMETRIC READER SETUP
1. Press to advance to and highlight Enable Biometric Reader
2. Press to check for Enable or uncheck for disable Biometric Reader
3. Once Enable Biometric Reader is checked, press to setup a biometric reader.
The following Biometrics Setup screen will display.
Biometrics on screen message ‘This test uses badge #1” is explained as; the user presses enter to run the bio test, it does an enroll, verify, and delete. The enrollment occurs for badge number ‘1’. If someone is already enrolled under that ID, the templates would be erased. Note: The Com4 setting is the Biometric reader default and should remain as is. Messages from firmware tests on the Biometric reader, calibration attempts, and com port configurations are displayed under the Configured Com Port section of the screen.
Revision –
6-15-06
27
Page 29
Genus™ G2 Users Manual 4. Press to test the reader.
Messages from the reader test may either prompt the user or provide information. These messages are as follows: Place Finger on Sensor... Finger enrolled, Remove Finger Place Finger on Sensor... Finger Verified, Remove Finger Template Deleted. Test Passed! Test Failed! 5. Press to calibrate the reader.
Messages from the reader calibration may also prompt or provide information. These messages are as follows: Calibrating Please do not touch sensor Calibration Successful Calibration Failed 6. Choose a Configured Com Port by using the arrow keys.
Messages from Com Port changes are as follows: Connecting to reader... Connection attempt failed! 7. Press to highlight Apply .
8. Press to save and return to the previous screen.
9. Or press
Revision – to exit
6-15-06
28
Page 30
Genus™ G2 Users Manual SYSTEM MAINTENANCE
1. From the options at the bottom of the display press to advance to and highlight Maint .
Maint - Test Com Port Test Com Port is used to test the DI/DO and the Serial Aux Port on the G2 Terminal. This test requires special test equipment. Contact CMI’s Technical Support for additional information.
Maint – Clear RAM Clear RAM will clear the ‘\ramdisk’ current transaction files residing in the terminal. 1. Press to highlight Clear RAM.
2. To clear RAM press Note: A WARNING screen will show confirming that all data will be lost. 3. Press
Revision – to continue or to cancel.
6-15-06
29