Page 10

3. General Features 3.1 Buzzer The buzzer of the scanner beeps differently to indicate various operating conditions. Power On: The scanner will issue a long beep indicating successful power on. Good Read: There are four beep tones (frequencies) that the user can select from to signify a good read. The available options are listed below. Frequency: 8 / 4 / 2 / 1 kHz Error: The scanner will issue a long beep with a low tone to indicate errors. Enter / Exit Configuration: The scanner will issue 6 beeps upon entering / exiting the configuration mode. Setup: In configuration mode, the scanner will normally beep twice when a setup barcode is read. If the particular setup parameter needs more than one read, the scanner will only issue a short beep to indicate that there are more setup barcodes needed to complete the current parameter setting.

3.2 Indicator There is a dual color indicator on the top of the scanner. Normally it is off, and it will turn green when there is a good read. The indicator will be green when the scanner is in configuration mode.

3.3 Reading Redundancy This parameter is used to specify the levels of reading (decoding) security. If No Redundancy is selected, only one successful decode will make the reading valid. If Three Times Redundancy is selected, it will take 3 successful decodes to make the reading valid. It is obvious that the more redundancy the user selects, the higher the reading security and thus the slower the reading speed. The user should be prepared to compromise between decode security and decode speed if the security feature is needed.

6

Page 11

3.4 Scan Modes There are eight scan modes supported by the CCD scanner. The user can choose the desired scan mode depending on the application requirements. The supported scan modes are described below. Auto Off Mode: The scanner will start scanning once the switch is triggered. The scanning continues until either a barcode is read or a preset scanning period (Scanner Time-Out Duration) has expired. Continuous Mode: The scanner is always scanning. Auto Power Off Mode: The scanner will start scanning once the switch is triggered. The scanning continues until a preset scanning period (Scanner Time-Out Duration) has expired. Unlike the Auto Off mode, the scanner will continue to scan and the scanning period is re-counted each time there is a successful read. Alternate Mode: The scanner will start scanning once the switch is triggered. The scanner will continue scanning until the switch is triggered again. Momentary Mode: The scanner will be in scanning mode as long as the switch is depressed. Repeat Mode: The scanner is always scanning just like Continuous Mode. But now the switch acts like a “re-transmit button”. If the switch is triggered within 1 second after a good read, the same data will be transmitted again without actually reading the barcode. This “re-transmit button” can be triggered as many times as the user desires, as long as the time between each trigger does not exceed 1 second. This scan mode is most useful when the same barcode is to be read many times. Laser Mode: This is the scan mode most often used on laser scanners. The scanner will start scanning once the switch is pressed. The scanning continues until either a barcode is read, the switch is released or a preset scanning period (Scanner Time-Out Duration) has expired. Test Mode: The scanner is always scanning. The scanner will decode repeatedly even the same barcode. By default, the scan mode is Auto Off mode for scanners with trigger switch.

3.5 Scanner Time-out Duration This parameter is used to limit the maximum scanning period when the scan mode is either Auto Off Mode or Auto Power Off Mode. This time-out duration is specified in units of seconds. The default time-out duration is 10 seconds.

7

Page 12

3.6 Negative Barcodes Your 1300 scanner can be configured to read negative barcodes. Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of the negative barcodes are printed with a color darker than that of the bars.

3.7 Transmit Buffer and Delay Setting Your 1300 scanner can be configured to buffer the data before transmitting it to the host. Used to activate and set a delay between the data transmitted to host.

3.8 Delay between Reread If the scanner mode is set to Continuous, Auto Power Off, Alternate, or Momentary mode, the scanner will prevent accidentally reading the same barcode twice by using a delay time. The barcode must be taken away from the scanning line longer than the Delay Time to allow a second reading of the same barcode.

3.9 Supported Symbologies Most of the popular barcode symbologies are supported. Each symbology can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. The supported barcode symbologies are listed below. Code 39 (Standard / Full ASCII) Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codabar (NW-7) UPCA (with or without Add-on) UPCE (with or without Add-on) EAN8 (with or without Add-on) EAN13 (with or without Add-on) Code 93 Code 128 EAN 128 MSI Plessey PDF417

8

Page 13

4. Output Interface Your 1300 is a multi-interface scanner. It can be configured as a keyboard wedge scanner, an RS-232 scanner, or a Wand emulation scanner. The output interface can be easily changed. This is done simply by using the appropriate interface cable and configuring the desired interface type.

4.1 Keyboard Wedge Interface 4.1.1 Keyboard Type The keyboard wedge interface is enabled by configuring/selecting the keyboard type. The supported keyboard types are listed below. PCAT - US, French German, Italian, Swedish, Norwegian, UK, Belgium, Spanish, and Portuguese KBD PS2-30 PS-55 IBM 5550 IBM 3477 TYPE (Japanese KBD) IBM 34XX,319X & Memorex Telex (122Keys) 4.1.2 Keyboard Style - Alphabets Keyboard layout style can also be selected. There are three options for this setting: default layout (US or English style), AZERTY layout, and QWERTZ layout. This setting only works when the keyboard type selected is for US keyboard. The scanner will make necessary adjustment when sending the „A‟, „Q‟, „W‟, „Z‟, „Y‟, and „M‟ characters according to this setting. 4.1.3 Keyboard Style – Digits There are two digit layout styles as shown on the following figures. One has its digit keys on top (upper row), the other has them on the bottom (lower row). The digit layout style can be changed by configuring this setting. There are three options to this setting: Default, Lower Row, and Upper Row. The scanner will make the necessary adjustments when sending digits according to the setting value of this parameter. This setting is intended for use with the Keyboard Style – Alphabets and perhaps Character Substitution setting, when support to languages not available on the scanner is needed. ! 1

@ 2

# 3

$ 4

Digits on Lower Row

9

Page 14

1 !

2 @

3 #

4 $

Digits on Upper Row 4.1.4 Capital Lock Status In order to send alphabets with correct case, the scanner needs to know the capital lock status of the keyboard. Incorrect settings may result in reversed case of alphabets being transmitted. There are 3 options to this parameter: On, Off, or Auto Detection. If this parameter is set to Auto Detection, the scanner will automatically detect the capital lock status of the keyboard before it transmits data. But the Auto Detection option is supported only when the keyboard type configured is PCAT (all available languages), PS2-30, PS55, IBM 34XX/319X, or Memorex Telex. 4.1.5 Alphabets Transmission The user can choose how alphabets are sent by configuring this parameter. The alphabets can be sent according to their case (the Case Sensitive option), or the case is ignored (the Ignore Case option) when being transmitted. 4.1.6 Digits Transmission The user can choose how the scanner transmits digits by configuring this parameter. The scanner can transmit digits by using the alphanumeric keys or by using the keys of the numeric key pad. The Num Lock status of the keyboard should be ON if the numeric key pad option is selected. Numeric Key Pad

Keyboard

Alphanumeric Key

4.1.7 Alt Composing This function allows you to emulate holding the ALT key and entering a number on the numeric pad to simulate a specific character. 4.1.8 Inter-Character Delay An inter-character delay of 0 to 255 ms can be configured to match the computer response time of the keyboard interface. The delay time configured is inserted between every transmitted character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

10

Page 15

4.2 Wand Emulation The Wand Emulation output interface is enabled by reading the “Activate Wand Emulation” label whilst in configuration mode. The user can select the signal levels of the normal status and bar status to be used as well as the Module and Margin times in this output interface. 4.2.1 Normal Status This setting specifies the signal level of the normal state when not transmitting a barcode image. 4.2.2 Bar Status This setting specifies the signal level used to represent a bar when transmitting a barcode image. 4.2.3 Module Time This setting specifies the time span for bar and space modules. 4.2.4 Margin Time This setting specifies the time span for change in state for bar and space modules. 4.2.5 PDF417 Block Delay This setting specifies the time delay required between PDF417 data blocks.

11

Page 16

4.3 RS232 Interface The RS-232 interface is enabled by reading the “Activate RS-232 Interface” label whilst in configuration mode. The user can select the desired transmission mode, flow control, baud rate, parity, and data bits to be used in this output interface. 4.3.1 Transmission Mode There are four transmission modes supported on the scanner when RS232 output interface is used. One of them is for single port operation, and the others are for dual port operation. Single port operation is used where the scanner is connected directly to the host computer, whereas the dual port operation is used where the scanner is connected between host and terminal. The interface cable for dual port operation always has two connectors, one of them is a male connector and the other one is a female connector. Under dual port operation, user can select whether data are transmitted to either ends or are transmitted to both ends. The supported transmission modes are listed below. Single Port Dual Port - Data are transmitted to male connector end. Dual Port - Data are transmitted to female connector end Dual Port - Data are transmitted to both ends. 4.3.2 Baud Rate / Parity / Data Bits The supported baud rate, parity, and data bit are listed below. Baud Rate : 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 300 / 110 Parity : None / Even / Odd Data bit : 8 / 7 4.3.3 Flow Control If the single port transmission mode is selected, user can further configure the flow (handshake) control method to be used. The available options are listed below. No Flow Control Scanner Ready : The scanner will activate the RTS signal after power on. After each good read the scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active. Data Ready : The RTS signal will be activated after each good read. The scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active. Inverted Data Ready : It is like the Data Ready flow control, but the RTS signal level is inverted.

12

Page 17

4.3.4 Inter-Character Delay An inter-character delay of 0 to 255 ms can be configured to match the computer response time. The delay time configured is inserted between transmitting every character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

4.4 Memory Parameters The following applies to Memory models only. ( models 1310 & 1311) 4.4.1 Memory Mode This setting enables or disables the memory function of the scanner. 4.4.2 Clear Data The CLEAR label will enable the user to CLEAR or ERASE the data in the scanner‟s memory. The user must also scan the CONFIRM label immediately after the CLEAR label. 4.4.3 Send Data This enables the user to transmit the data in the scanner‟s memory to the host. The interface selected by the user will be used for the transmission. 4.4.4 Memory Data Delay This will enable the user to set a delay between data records in memory at time of transmission.

13

Page 18

5. Data Output Format Data read by the scanner will be processed in the following sequence (RS-232 and Keyboard Wedge interfaces only). 1) The character substitution is performed on the barcode data. 2) The Code ID and the Length Code are inserted at the beginning of the data as shown below. [Code ID] [Length Code] [Data] 3) The resulting data of step 1 will be processed by the editing formats. For details, please refer to the section “Data Editing”. 4) And finally the Prefix Code and the Postfix Code will be added before transmission. [Prefix Code] [Resulting Data of Step 3] [Postfix Code]

5.1 Prefix / Postfix Code Up to 10 characters of prefix / postfix code can be configured for the scanner.

5.2 PDF417 Prefix / Postfix Code Up to 10 characters of prefix / postfix code can be configured for the scanner.

5.3 Data Substitution There are 6 string substitution settings on the scanner. These settings are configured on a string base. That is, a specific string is to be substituted by an another string. The string substitution is performed on every occurrence of the string specified in these settings. Be aware, the substitution is performed only on the barcode itself (exclude Prefix Code, Postfix Code, Code ID, Length Code or any Additional Field) and is performed before editing mode processing. If only the string to be replaced is specified, every occurrence of that string in the barcode will be taken away.

5.4 Code ID Up to 10 characters of Code ID can be configured for each symbology. To minimize the Code ID configuration efforts, the scanner provides five predefined Code ID Sets that the user can select from. The user can first select one of the Code ID Sets and then make desired modifications. The pre-defined Code ID Sets are shown below.