Page 19

Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codabar Code 93 Code 128 UPCE EAN8 EAN13 MSI Plessey UPCA

Set 1 Set 2 Set 3 Set 4 Set 5 A C Y M A A C Y M A A C Y M A C H H H S D I Z I S E G G G S F N X N F I L L L G H K K K C S E C E E P B B FF E M A A F E V V D P M W W E Q P M A A F E

5.5 Length Code Two digits Length Code representing the length of data (character count) can be inserted in front of data being transmitted. This Length Code parameter can be individually enabled or disabled for each barcode symbology. For PDF417 the length code is 4 digits.

15

Page 20

6. Symbology Parameters This section describes user configurable parameters which are pertaining to barcode symbologies.

6.1 Select Readable Codes Use this parameter to enable or disable the type of barcode to be read.

6.2 Code39 Standard / Full ASCII Code 39: User can choose to read either Standard Code 39 or Full ASCII Code 39 by configuring this parameter. Start/Stop Transmission: This parameter specifies whether the start/stop characters of Code 39 are included in the data being transmitted. Checksum Verification: This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read. Checksum Transmission: This parameter specifies whether the checksum characters are included in the data being transmitted.

6.3 Italy / French Pharmacode For Italy /French Pharmacode, there is always a checksum character included in the barcode. So the checksum verification is always performed when decoding these symbologies. User though can choose whether the checksum character is to be transmitted or not. The start / stop transmission of this code shares the same setting of Code 39. Checksum Transmission: This parameter specifies whether the checksum characters are included in the data being transmitted.

6.4 Industrial / Interleave / Matrix 25 Start / Stop Selection: This parameter provides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 25 barcode but with Interleave 25 start / stop. In order to read this barcode, the start / stop selection parameter of Industrial 25 should set to „Interleave 25. Checksum Verification: This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read. Checksum Transmission: This parameter specifies whether the checksum characters are included in the data being transmitted. Code Length Qualification: Because of the weak structure of the 2 of 5 codes, a partial scan has a high probability of decoding as a valid but shorter 2 of 5 codes (known as short scan). To prevent this kind of undesired

16

Page 21

reading, the Code Length settings can help to insure that the correct code is read by qualifying the allowable code length. Code length parameters can be configured in two ways: Fixed Code Length or Max / Min code length. If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the min length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified.

6.5 Codabar Start/Stop Transmission: This parameter specifies whether the start/stop characters of Codabar are included in the data being transmitted. Start / Stop Selection: Four different start / stop pairs can be selected as start / stop characters as listed below. abcd / abcd abcd / tn*e ABCD / ABCD ABCD / TN*E

6.6 Plessey Convert to UK Plessey: If this parameter is enabled, the scanner will change each occurrence of the character „A‟ into character „X‟ in the code. Checksum Transmission: If this parameter is enabled, the checksum characters (two characters) will be transmitted together with data.

6.7 MSI Checksum Verification: Three kinds of checksum calculations can be implemented into MSI code: Single Modulo 10, Double Modulo 10, or Modulo 11 & 10 checksum. If the checksum character is incorrect, the barcode will not be read. Checksum Transmission: User can control how the checksum is transmitted by configuring this parameter. 1) Transmitted 2) Last digit not transmitted 3) Last 2 digits not transmitted

17

Page 22

Code Length Qualification: Because of the weak structure of the MSI code, a partial scan has a high probability of decoding as a valid but shorter MSI codes (known as short scan). To prevent this kind of undesired readings, the Code Length settings can help to ensure that the correct code is read by qualifying the allowable code length. Code length limitations can be set in 2 ways: Fixed Code Length and Max/Min code length. If the fixed code length is selected, up to 2 fixed lengths can be specified. And if max / min code length is selected, the max length and the min length must be specified, and the scanner will only accept those codes with lengths fall between max / min length specified.

6.8 EAN128 Field separator: Enter the field separator for EAN128 barcode scanning.

6.9 PDF417 Escape Character: Enter the escape character required for PDF417 codes.

6.10 EAN8 Convert to EAN13: If this parameter is enabled, the EAN8 read will be expanded into EAN13, and the following processing will follow the parameters configured for EAN13. Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.

6.11 UPCA Convert to EAN13: If this parameter is enabled, the UPCA read will be expanded into EAN13, and the following processing will follow the parameters configured for EAN13. System Number Transmission: If this parameter is enabled, the system number will be included in the data being transmitted. Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.

6.12 UPCE System Number Selection: The UPCE comes with 2 flavors: System Number 0 and System Number 1. These two differ in the way data are encoded. The system number 1 is the new UPCE extension to the ordinary UPCE (system number 0). User can have the choice of enabling both system numbers, or just system number 0. Warning: Because of the way system number 1 is encoded, if both system numbers are enabled, user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes.

18

Page 23

Convert to UPCA: If this parameter is enabled, the UPCE read will be expanded into UPCA, and the following processing will follow the parameters configured for UPCA. System Number Transmission: If this parameter is enabled, the system number will be included in the data being transmitted. Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.

6.13 EAN13 ISBN / ISSN Conversion: If these parameters are enabled, the scanner will convert the code read into ISBN or ISSN code if the formats are correct (EAN13 codes start with 978 or 979 for ISBN, and 977 for ISSN). Checksum Transmission: If this parameter is enabled, the checksum character will be included in the data being transmitted.

19

Page 24

7. Data Editing The 1300 scanner provides advanced data editing functions for data formatting. Data editing is performed according to user configured editing formats. Up to 7 editing formats can be configured. Data is divided into fields by user specified rules. These fields together with user configurable additional fields constitute the data actually sent to the host computer. The detailed descriptions and the configuration procedures of the editing format are described in this section.

7.1 Activate Data Editing Formats Before data can be processed by a particular editing format, that format must be enabled. The editing formats can be enabled or disabled individually. There are up to 7 data editing formats.

7.2 Exclusive Data Editing If this parameter is enabled, all data read by the scanner must be processed by the editing format. If the data is not eligible for all enabled editing formats, the scanner will not accept the reading and the data will not be transmitted.

7.3 Select Editing Format To start configuring an editing format, the editing format to be configured must first be selected. Once it is selected, the parameters pertaining to editing format (applicable condition, total number of field, field dividing rules, additional fields, and field transmission sequence parameters) can be configured. After all the desired parameters are configured, the “End of Format Programming” label must be read to complete the configuration of that editing format. Note: Before completing the configuration of the editing format, if parameters other than those pertaining to editing format are read, the editing format under configuration will be aborted. User must restart the configuration again by selecting editing format to be configured.

7.4 Restore Default Format After the editing format to be configured is selected, user can read the “Restore Default Format” label to put the editing format back to default setting. The default settings of the editing format are listed below. Applicable Code Type: All Applicable Length: Both max and min length are zero. Matching string: Empty Matching String Location: 0 Total number of field: 1 Field Setting: Not Configured

20

Page 25

Additional Fields: Empty Field Transmission Sequence: F1

7.5 Applicable Conditions Three applicable conditions can be configured to qualify whether the data read by the scanner can be processed by the particular editing format. Data editing will not be performed unless all three applicable conditions are met the configurable applicable conditions are described below. Data Length: This parameter specifies the length (character count) of the data eligible for data editing. It is specified in the range format. The length of the data must fall between max and min length limits. If the max length and the min length configured is both zero, the scanner will not perform this length qualification. (field is up to 4 digits) Matching String and its Location: User can specify a particular character string (up to 10 characters) that must appear in the data which is eligible for data editing. User can also specify where (character position, starts from one) this string should appear in the data by configuring the matching string location. If the location specified is zero, the scanner only checks for the existence of the matching string in the data. To disable the matching string qualification, just leave the matching string empty. Code Type: This parameter specifies the code type of the data eligible for data editing. Multiple code types can be specified for this parameter.

7.6 Total Number of Fields Data can be divided into at most 6 fields. The total number of fields configured must be correctly specified. The fields are numbered from F1 to F6 accordingly, but only F1 to F5 can be configured. Please note that, the number of fields can be configured is always one less than total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field. That is, if three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats.

7.7 Separating Data into Fields Data eligible for editing format is separated into fields according to user specified rules. The rule for each field can be configured in two ways. Field Terminating String: Field separation can be configured by specifying the field terminating string. The field terminating string configured can be up to 2 characters. The scanner will search for the occurrence of this particular string in the data for the field. The field terminating string is always included in the field. User though, has the option of discarding this terminating string.

21

Page 26

Field Length: Field separation can be configured by simply specifying the field length. The scanner will assign the next specified number of characters into the field. (Max is 9999)

7.8 Additional Fields User can create up to five additional fields for each editing format. Each additional field can have at most four characters. The additional fields are numbered AF1 to AF5 accordingly.

7.9 Field Transmission Sequence After the data fields and the additional fields are configured, user can now program the transmission sequence of these fields that comprise the final data. The “Start” label must be read before assigning the field transmission sequence. And then the desired field transmission sequence can be specified. The scanner will transmit the fields in the order (sequence) user programmed when sending data. The field transmission sequence can be assigned in any desired order and fields can also be assigned multiple times. The maximum number of fields can be assigned is twelve. After the sequence has been assigned, the “End” label must be read to complete the setting.

7.10 End of Format Programming After all the desired parameters are configured, the “End of Format Programming” label must be read to conclude the programming of the editing format. This label is located at the bottom of every even page in the “Editing Format Parameters” section of the configuration manual.

7.11 Programming Examples Example 1 : Extracts data from the 10th character to the 19th character. Total Number of Fields : 3 Field 1 : Divide field by field length, set field length to 9 Field 2 : Divide field by field length, set field length to 10 Field Transmission Sequence : F2 Example 2 : Extract the date code, item number, and quantity information from barcodes. Data is encoded in the barcode like this : From the first character to the 6th character is the date code. From the 7th character is the item number, its length is not fixed but is delimited by a „-‟ character. After the „-‟ character is the quantity information. Data should be transmitted like this : Item number goes first, then a TAB character, and then the date code, and then another TAB character and finally the quantity.

22

Page 27

Total Number of Fields : 3 Field 1 : Divide field by field length, set the field length to 6. Field 2 : Divide field by field terminating string. Set terminating string to „-‟, and discard the terminating string. Additional Field 1 : Set to one TAB character. Field Transmission Sequence : F2 AF1 F1 AF1 F3

23