The text of a manual · part 1 of 3

Cipher 1300 Series User's Manual, pages 1 to 9

Pages 1 to 9 of 27

The original document is the PDF (304 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the CipherLab 1300, CipherLab 1301 and CipherLab 1311

Page 1

CIPHER 1300 SERIES

User’s Manual

Document Number : 6790-0116 Release Date : November 06, 1998 2000, SYNTECH INFORMATION Co., Ltd.. All rights reserved. CipherLab is a registered trademark of SYNTECH INFORMATION Co., Ltd.

Page 2

WARNING This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

Page 3

Table of Contents 1. 2.

Introduction ..........................................................1 Configuring 1300 .................................................2 2.1 Enter Configuration Mode ...........................2 2.2 Default..........................................................2 2.3 List Setting ...................................................2 2.4 Setting Parameter Values .............................2 2.4.1 Numeric Parameters .............................3 2.4.2 Character String Parameters .................3 2.4.3 Key Type/Status Setting .......................4 2.5 Exit Configuration Mode .............................5 3. General Features ..................................................6 3.1 Buzzer ..........................................................6 3.2 Indicator .......................................................6 3.3 Reading Redundancy....................................6 3.4 Scan Modes ..................................................7 3.5 Scanner Time-out Duration ..........................7 3.6 Negative Barcodes .......................................8 3.7 Transmit Buffer and Delay Setting ...............8 3.8 Delay between Reread ..................................8 3.9 Supported Symbologies................................8 4. Output Interface ...................................................9 4.1 Keyboard Wedge Interface...........................9 4.1.1 Keyboard Type .....................................9 4.1.2 Keyboard Style - Alphabets..................9 4.1.3 Keyboard Style – Digits .......................9 4.1.4 Capital Lock Status ............................10 4.1.5 Alphabets Transmission .....................10 4.1.6 Digits Transmission............................10 4.1.7 Alt Composing ...................................10 4.1.8 Inter-Character Delay .........................10 4.2 Wand Emulation.........................................11 4.2.1 Normal Status .....................................11 4.2.2 Bar Status ...........................................11 4.2.3 Module Time ......................................11 4.2.4 Margin Time.......................................11 4.2.5 PDF417 Block Delay .........................11 4.3 RS232 Interface..........................................12 4.3.1 Transmission Mode ............................12 4.3.2 Baud Rate / Parity / Data Bits ............12 4.3.3 Flow Control ......................................12

Page 4

4.3.4 Inter-Character Delay......................... 13 4.4 Memory Parameters ................................... 13 4.4.1 Memory Mode ................................... 13 4.4.2 Clear Data .......................................... 13 4.4.3 Send Data ........................................... 13 4.4.4 Memory Data Delay ........................... 13 5. Data Output Format ........................................... 14 5.1 Prefix / Postfix Code .................................. 14 5.2 PDF417 Prefix / Postfix Code.................... 14 5.3 Data Substitution........................................ 14 5.4 Code ID...................................................... 14 5.5 Length Code ............................................... 15 6. Symbology Parameters ...................................... 16 6.1 Select Readable Codes ............................... 16 6.2 Code39 ....................................................... 16 6.3 Italy / French Pharmacode ......................... 16 6.4 Industrial / Interleave / Matrix 25 .............. 16 6.5 Codabar ...................................................... 17 6.6 Plessey ....................................................... 17 6.7 MSI ............................................................ 17 6.8 EAN128 ..................................................... 18 6.9 PDF417 ...................................................... 18 6.10 EAN8 ......................................................... 18 6.11 UPCA......................................................... 18 6.12 UPCE ......................................................... 18 6.13 EAN13 ....................................................... 19 7. Data Editing ....................................................... 20 7.1 Activate Data Editing Formats ................... 20 7.2 Exclusive Data Editing............................... 20 7.3 Select Editing Format ................................ 20 7.4 Restore Default Format .............................. 20 7.5 Applicable Conditions ............................... 21 7.6 Total Number of Fields .............................. 21 7.7 Separating Data into Fields ........................ 21 7.8 Additional Fields........................................ 22 7.9 Field Transmission Sequence ..................... 22 7.10 End of Format Programming ..................... 22 7.11 Programming Examples ............................. 22

Page 5

1. Introduction +

This User‟s Manual contains all the information needed to operate and configure your 1300 linear imaging CCD Barcode Scanner. It is divided into two parts. The first part of this manual describes the operation and programmable features of the scanner. The second part of this manual contains the setup barcodes used to configure the scanner.

+

The CipherLab 1300 scanner is one of the most versatile and flexible barcode scanners in the world. All the features and functions required for up to date barcode reading are included. Owing to its rugged design and low power consumption, this scanner provides for easy installation and high product durability. The 1300 scanner can not only fulfill the requirements needed today, but also will meet your requirements of tomorrow. The main functions and features provided on your 1300 scanner are listed below. Barcode Readability: Most popular barcode symbologies are supported. Support for PDF417 (models 1301, 1311, 1321) Memory Support (models 1310 and 1311) Support for negative barcodes. Support eight scan modes. Programmable Buzzer Volume and Beeping Tone Dual Color Indicator Multi-Interface Support : KBD Wedge, RS232 (Single/Dual Port), and Wand Emulation Programmable Code ID: Code ID can be individually configured for each symbology. Programmable Length Code Programmable Prefix Code Programmable Postfix Code Character Substitution Data Editing : Data can be reorganized according to user programmable formats. Up to 7 data editing formats are supported. Low Power Consumption

1

Page 6

2. Configuring 1300 Configuring the 1300 Scanner is done by reading the setup labels contained in the Configuration Manual (the second part of this manual). This section describes the procedure of configuring the scanner. Some configuration examples are also given in this section for illustration.

2.1 Enter Configuration Mode To start the configuration, the “Enter Setup” label must be read. This will put the scanner in the configuration mode. The scanner will respond with 6 beeps and the indicator will turn green after the label is read. This “Enter Setup” label is located at the bottom of almost every even page of the Configuration Manual.

2.2 Default All the parameters of the scanner will return to their default values by reading the “Default” label. The scanner will beep twice when the “Default” label is read.

2.3 List Setting The current setting of all scanner parameters can be sent to the host computer for user inspection. The listing is separated into ten pages. User can select the page of interest by reading the “Page x” label. The scanner can not list setting, if Wand Emulation interface is configured. Page 1 : Interface, Buzzer, and Scanner Parameters Page 2 : Prefix, Postfix, and Length Code Setting Page 3 : Code ID Page 4 : Readable Symbologies Page 5 : Symbology Parameters (1/3) Page 6 : Symbology Parameters (2/3) Page 7 : Symbology Parameters (3/3) Page 8 : Editing Format 1 Page 9 : Editing Format 2 Page 10 : Editing Format 3

2.4 Setting Parameter Values For most of the parameters, only one reading is required to set them to new values. The scanner will respond with two beeps when these parameters are configured. But for some special parameters, multiple readings are required to complete the setting. The scanner will respond with a short beep if the configuration of the parameter is still not complete. These parameters usually refer to a numeric value or a string of characters, such as keyboard type, inter-character delay, prefix / postfix code, etc.. For these kinds of parameters, the label of the parameter to be configured must be read first. And then, the labels comprising the numeric value or

2

Page 7

character string are read. And finally, the “Validate” label must be read to complete the setting. The scanner will respond with two beeps when the “Validate” label is read. 2.4.1 Numeric Parameters The configuration procedures for numeric parameters are shown below.

Parameter Label

Decimal Label

"Validate" Label For example, to configure the Inter-Character Delay to be 15 ms, the “InterCharacter Delay” label is first read, and then the decimal digit labels “1” and “5”, and finally, the “Validate” label to complete the setting. 2.4.2 Character String Parameters Basically, each character programmed in the character string parameter is represented by two hexadecimal digits. The two hexadecimal digits usually comprise a value that is the ASCII code equivalence of the character being programmed. Beside the two hexadecimal digits, there is an optional key type/status can also be specified for each character of the string parameters. This optional key type/status can only be specified for some particular parameters when keyboard interface is used. These parameters are : Prefix Code, Postfix Code, Code ID, and Additional Fields of Editing Formats. The available key type/status settings can be selected will be described briefly. The configuration procedures for character string parameters are shown below.

3

Page 8

Parameter Label

Key Type / Status Label

Two Hexadecimal Labels

"Validate" Label For example, to configure the Prefix Code to be “AB”, the “Prefix Code” label is first read, and then the hexadecimal digit labels “4”, “1”, “4”, and “2” are read, and finally, the “Validate” label to complete the setting. 2.4.3 Key Type/Status Setting The key type/status is specified in character basis. Each character programmed is by default of Normal key type. A character of normal key type can have associate status settings (add Shift/Control/Alternate). Whereas a character of Scan Code type may not have any associate key status settings. Normal Key Type: When this label is read, the scanner will assume the following hexadecimal digits are the ASCII code of the character being programmed. And it will also clear all the associate key status settings made to the current character. Scan Code : When this label is read, the scanner will assume the following hexadecimal digits are the scan code value of the character being programmed. Add Shift : The Shift key will be sent together with the character programmed. Add Control (L) : The left Control key will be sent together with the character programmed. Add Alternate (L) : The left Alternate key will be sent together with the character programmed.

4

Page 9

Add Control (R) : The right Control key will be sent together with the character programmed. Add Alternate (R) : The right Alternate key will be sent together with the character programmed. For example, to program the Prefix Code to be “Ctrl-Shift-B”, “C”, the programming sequence should be : 1) “Prefix Code” label 2) “Add Control (L)” label 3) “Add Shift” label 4) “4” of the hexadecimal digit 5) “2” of the hexadecimal digit 6) “4” of the hexadecimal digit 7) “3” of the hexadecimal digit 8) “Validate”

Note : In internal representation of the characters which are specified with either scan code or associate key status, occupy two normal character space each. So the maximum number of characters can be configured for a string parameter will decrease, if these character specifications are used.

2.5 Exit Configuration Mode Both the “Update”, and the “Exit Setup without Changes” labels will exit the scanner from configuration mode when they are read. These two labels differ in whether to keep the new settings on the scanner or not, as their names suggest. The scanner will respond with 6 beeps and restart itself, if either label is read.