The text of a manual · part 7 of 8

Owner's Manual: A Series, AC11 Series, ES Series, F Series, and G Series Multiport Controllers, pages 61 to 70

Pages 61 to 70 of 77

The original document is the PDF (195 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the BayTech 529 and BayTech 524

Page 61

6.5

5218FP CONFIGURATION PROCEDURE

All configuration changes must be made through the host port. This is Port 18. To access the configuration mode of the multiport, connect a terminal (or a PC running a terminal emulation program) to the host port. To review the configuration status of all ports, send from this device ASCII Control-T (14 Hex), capital C, followed by 00. To reconfigure a particular port, send ASCII Control-T, capital C, followed by the desired peripheral port number (01 to 18).

6.5.1

5218FP - STATUS

The 5218FP will respond to the receiving of Control-T, capital C, and 00 from the host device with the following menu: Bay Technical Associates Model 5128F Network Controller Copyright 1983 Revision 2.03 PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

BAUD RATE 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600 9600

6.5.2

WORD SIZE 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

STOP BITS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

PARITY NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE

5218FP - SERIAL PORT CONFIGURATION

You may reconfigure individual peripheral ports by sending ASCII Control-T (14 Hex), capital C, followed by a two-digit port number (01 to 18). 55

Page 62

The 5218FP will respond to the receiving of Control-T, capital C, and the appropriate port number with a current status of that peripheral port and a list of options. For example, if you wish to reconfigure peripheral Port 3, send Control-T, C, followed by 03. The 5218FP will respond back with the following menu: CURRENT PORT CONFIGURATION PORT

BAUD RATE

WORD SIZE

STOP BITS

PARITY

3

9600

8

1

NONE

QUIT………………..1 SET BAUD RATE… .2 SET WORD SIZE…..3

SET STOP BITS.....4 SET PARITY...…...5

ENTER REQUEST: You may now reconfigure Port 3 by selecting the appropriate option (1-5) from the menu. For example, to change the baud rate to 300 baud, send character 2 (set baud rate). The 5218FP will respond with the following menu: 1 2 3 4 5 6 7 8

FOR FOR FOR FOR FOR FOR FOR FOR

110 135 300 600 1200 2400 4800 9600

ENTER REQUEST: NOTE: A colon (:) always precedes a request for data from the 5218FP unit. Send a "3" for 300 baud rate and the 5218FP will respond with the following menu:

56

Page 63

CURRENT PORT CONFIGURATION PORT

BAUD RATE

WORD SIZE

STOP BITS

PARITY

3

300

8

1

NONE

QUIT.............……….....1 SET BAUD RATE.........2 SET WORD SIZE..........3

SET STOP BITS.....4 SET PARITY....…..5

ENTER REQUEST: If there are no other changes for this port, send a "1" to exit the serial port configuration mode for Port 3. The 5218FP will respond with the following message: Save Changes Permanently? (Y/N): NOTE: When changing the configuration of the host port, the multiport will also respond with: Change Host Device to NEW Configuration Before Answering This Request. Change the host device's serial parameters to match the new configuration of the host port before answering "Y" (yes) or "N" (no). If you answer "Y" (yes), the new configuration for that port will be stored permanently in non-volatile memory, and the multiport will subsequently power-up at the new configuration. If you answer "N" (no), the new configuration will be stored in RAM, and on the next power-up, the multiport will revert to the previous configuration. NOTE: Menu selection is case sensitive. Be sure to enter Capital Y or Capital N in response to the prompt. The 5218FP will now return to the operations mode.

6.6

NON-VERBOSE MODE

Multiports power-up in the verbose or menu-driven mode. Only in the menu-driven mode can changes be saved permanently in non-volatile memory. The non-verbose mode, however, may be preferable in some instances. When configuring a multiport using non-verbose mode, no menus are sent from the multiport which allows you to program the unit by downloading an ASCII character string. This mode applies only to configuration and does not affect operations. 57

Page 64

NOTE: Changes made using non-verbose mode are not saved in non-volatile memory and will be lost upon power-down, whereupon the power-up default configuration will again be in effect. The following models support non-verbose mode: 524x(P), 524F(P), 524G, 528G, all 528x(P) units (x = A, AC11, ES, or NB), 5218AP, 5218AC11P, 5218ESP, and the 5218FP.

6.6.1

ALL 524 MODELS EXCEPT 524F(P) NON-VERBOSE MODE CONFIGURATION PROCEDURE

For these models, non-verbose mode is selected by sending ASCII Control-R followed by "5" to the host port. Your ASCII character string would start off with: ^R5^RX<...>, where ^R represents Control-R, X is the number of the port (1 to 4) you wish to configure, and ... indicates the remainder of your character string which would consist of choices selected from the following menus: A. MAIN MENU Quit....................................1 Set Baud Rate....................2 Set Word Size....................3 Set Stop Bits......................4 Set Parity...........................5 Exit ....................................X B. SET BAUD RATE MENU 300..................1 600..................2 1200................3 2400................4 4800................5 9600................6 19200..............7 C) SET WORD SIZE MENU 5....................1 6....................2 7....................3 8....................4 D) SET STOP BITS MENU 1....................1 1 1/2..............2 2....................3 58

Page 65

E) SET PARITY MENU None.................1 Even.................2 Odd..................3 To return to the verbose mode, send the multiport Control-R followed by ASCII "6". If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.2

524F(P) - NON-VERBOSE MODE CONFIGURATION PROCEDURE

Non-verbose mode for the 524F(P) is selected by sending ASCII Control-T followed by capital I. Your ASCII character string would start off with: ^TI^TX<...>, where ^T represents Control-T, X is the letter corresponding to the desired peripheral port (A to D for Port 1 to Port 4) and ... indicates the remainder of your character string which would consist of choices selected from the menus shown on the previous page. To return to the verbose mode, send the multiport ASCII Control-T followed by capital J. If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.3

ALL NON-PROGRAMMABLE 528 MODELS

Non-verbose mode for all non-programmable 528 models is selected by sending ASCII Control-T followed by capital I. Your ASCII character string would start off with: ^TI^TX<...>, where ^T represents Control-T, X is the letter corresponding to the desired peripheral port (A to H for Port 1 to Port 8) and ... indicates the remainder of your character string which would consist of choices selected from the following menus: A. MAIN MENU Quit....................................1 Set Baud Rate....................2 Set Word Size....................3 Set Stop Bits......................4 Set Parity...........................5 Exit ....................................X

59

Page 66

B. SET BAUD RATE MENU 135..................1 150..................2 300..................3 600..................4 1200................5 2400................6 4800................7 9600................8 C) SET WORD SIZE MENU 5....................1 6....................2 7....................3 8....................4 D) SET STOP BITS MENU 1....................1 1 1/2..............2 2....................3 E) SET PARITY MENU None………….1 Even…………..2 Odd.…...............3 To return to the verbose mode, send the multiport ASCII Control-T followed by capital J. If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.4

ALL 528 AP, AC11P, ESP, AND NBP MODELS - NON-VERBOSE MODE CONFIGURATION PROCEDURE

Non-verbose mode for these models is selected by sending ASCII Control-T followed by capital I. Your ASCII character string would start off with: ^TI^TC<...>, where ^T represents Control-T and ... indicates the remainder of your character string which would consist of choices selected from the menus shown in the following subsections:

6.6.4.1

528AP, 528NBP, 5218AP - NON-VERBOSE MODE CONFIGURATION MENUS

Refer to the following menus to configure the 528AP, 528NBP, or 5218AP when using non-verbose mode. 60

Page 67

A. MAIN MENU Status..................………….......1 Set Serial Port Configuration....2 Set Control Character.......….....3 Set Xon/Xoff Handshaking.......4 Exit ..........................…………..X B. SET SERIAL PORT CONFIGURATION MENU Enter port number. Exit/Save.....................………...1 Set baud rate..................……….2 Set word size.................……….3 Set stop bits.................………...4 Set parity....................………....5 a) SET BAUD RATE MENU 110..................1 135..................2 300..................3 600..................4 1200................5 2400................6 4800................7 9600................8 b) SET WORD SIZE MENU 5....................1 6....................2 7....................3 8....................4 c) SET STOP BITS MENU 1....................1 1 1/2..............2 2....................3 d) SET PARITY MENU None................1 Even.................2 Odd..................3 C. SET CONTROL CHARACTER Enter control character in HEX. D. SET XON/XOFF HANDSHAKING Xon/Xoff Handshaking? (Y/N)

61

Page 68

To return to the verbose mode, send the multiport ASCII Control-T (or current control character) followed by capital "J". If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.4.2

528AC11P, 5218AC11P - NON-VERBOSE MODE CONFIGURATION MENUS

Refer to the following menus to configure the 528AC11P or 5218AC11P when using non-verbose mode. A. MAIN MENU Status.............…………..........……1 Set Serial Port Configuration.…….2 Set Control Character..………........3 Set Message Terminate Character...4 Set Xon/Xoff Handshaking......…...5 Exit .......................…………….......X B. SET SERIAL PORT CONFIGURATION MENU Enter port number. Exit/Save......................1 Set baud rate.................2 Set word size................3 Set stop bits ..................4 Set parity......................5 a) SET BAUD RATE MENU 110..................1 135..................2 300..................3 600..................4 1200................5 2400................6 4800................7 9600................8 b) SET WORD SIZE MENU 5....................1 6....................2 7....................3 8....................4

62

Page 69

c) SET STOP BITS MENU 1...................1 1 1/2.............2 2...................3 d) SET PARITY MENU None................1 Even.................2 Odd..................3 C. SET CONTROL CHARACTER Enter control character in HEX (2-digit). D. SET MESSAGE TERMINATE CHARACTER Enter message terminate character in HEX (2-digit). E. SET XON/XOFF HANDSHAKING Xon/Xoff Handshaking? (Y/N) To return to the verbose mode, send the multiport ASCII Control-T (or current control character) followed by capital "J". If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.4.3

528ESP, 5218ESP - NON-VERBOSE MODE CONFIGURATION MENUS

Refer to the following menus to configure the 528ESP or 5218ESP when using nonverbose mode. A. MAIN MENU Status.......................…………...1 Set Serial Port Configuration.….2 Set Data Block Length.......….....3 Set Control Character.....….…....4 Set Xon/Xoff Handshaking.........5 Exit ................…………..............X B. SET SERIAL PORT CONFIGURATION MENU Enter port number. Exit/Save........................1 Set baud rate...................2 Set word size..................3 Set stop bits .......….........4 Set parity............…........5

63

Page 70

a) SET BAUD RATE MENU 110..................1 135..................2 300..................3 600..................4 1200................5 2400................6 4800................7 9600....…........8 b) SET WORD SIZE MENU 5....................1 6....................2 7....................3 8....................4 c) SET STOP BITS MENU 1....................1 1 1/2..............2 2....................3 d) SET PARITY MENU None................1 Even.................2 Odd..................3 C. SET DATA BLOCK LENGTH Enter desired data block length (1 to 250 characters). Insert Carriage Return if less that three digits are entered. D. SET CONTROL CHARACTER Enter control character in HEX (2-digit). E. SET XON/XOFF HANDSHAKING Xon/Xoff Handshaking? (Y/N) To return to the verbose mode, send the multiport ASCII Control-T (or current control character) followed by capital "J". If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.5

5218FP - NON-VERBOSE CONFIGURATION PROCEDURE

Non-verbose mode for the 5218FP is selected by sending ASCII Control-T followed by capital I. Your ASCII character string would start off with: ^TI^TCXX<...>, where ^T represents Control-T, XX represents the desired port number (01 to 18), and ... indicates 64