Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 8

Owner's Manual: A Series, AC11 Series, ES Series, F Series, and G Series Multiport Controllers, pages 51 to 60

Pages 51 to 60 of 77

The original document is the PDF (195 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the BayTech 529 and BayTech 524

Page 51

NOTE: The 525GP or 529GP will show Set XON/XOFF as an additional item (6) in the submenu above which allows XON/XOFF handshaking to be enabled or disabled for individual ports. The multiport will respond with: 1 For 2 For 3 For 4 For 5 For 6 For 7 For 8 For

110 135 300 600 1200 2400 4800 9600

Enter request: NOTE: The 525GP will a different set of baud rate options with the maximum being 19200. Enter "6" for 2400 baud rate, and the multiport will respond with the reconfigured status of the port and the menu of options:

Port 3

Baud Rate 9600

Exit/Save………1 Set baud rate…...2 Set word size…..3

Word Size 8

Stop Bits 1

Pariity None

Xon/ Xoff Off

Set stop bit…..4 Set parity…….5

Enter request: If there are no other changes for this port, enter "1" (Exit/Save), and the multiport will respond with: Save Changes Permanently? (Y/N): NOTE: When changing the configuration of the host port, the multiport will also respond with: Change Device to NEW Configuration Before Answering This Request. This reminds you to make sure that the new configuration of the host port matches the configuration of the host device. If they do not match, the multiport will be unable to

45

Page 52

interpret the command, and, therefore, the user will be unable to access any multiport function. Change the host device's serial parameters to match the new configuration of the host port before answering "Y" (yes) or "N" (no). If you answer "Y" (yes), the new configuration for that port will be stored permanently in non-volatile memory, and the multiport will subsequently power-up at the new configuration. If you answer "N" (no), the new configuration will be stored in RAM, and on the next power-up, the multiport will revert to the previous configuration. The multiport will now return to the main configuration menu.

6.3.7

SET CONTROL CHARACTER

NOTE: This section does not pertain to the 5218GP. By responding to the Enter Request: message at the end of the main configuration menu with "3" for the 528/5218AP or 528/5218AC11P or with "4" for the 528/5218ESP (Set Control Character), you may user-define the control character. CAUTION: BayTech advises you to log your new control character. If it is forgotten, you will not be able to control the unit or access the configuration mode. The multiport will respond with: Current Control Character is ...............14H Enter Control Character in Hex.............: You may now enter the new control character that you want in Hex (00-7F Hex). For example, if you enter "15" (Control-U), the multiport will respond with: Current Control Character is ...............15H Save Changes Permanently? (Y/N): If you answer "Y" (yes), the new control character will be saved in non-volatile memory, and the multiport will respond only to that character. The multiport will respond with: Are You Sure? (Y/N): This message gives you a second chance to consider this change and reminds you to log your new control character. 46

Page 53

If you answer either question with "N" (no), the new control character will be stored in RAM and lost upon next power-up. The multiport will return to the main configuration menu.

6.3.8

528AC11P, 5218AC11P MODELS - SET MESSAGE TERMINATING CHARACTER

By responding to the Enter Request: message at the end of the configuration menu for the 528AC11P or 5218AC11P with a "4" (Set Terminate Character), you may custom set the terminating character. The multiport will respond with: Current Terminate Character is ............0DH Enter Terminate Character in Hex..........: Enter the terminating character that you wish in the form of a two-digit hexadecimal number. The multiport will then respond with: Save Changes Permanently? (Y/N): If you enter a "Y", the change will be saved in non-volatile memory, and the multiport will subsequently power-up with that terminating character in effect. If you enter a "N" (no), the terminating character will be stored in RAM only, and on the next power-up, the multiport will revert to the previous terminating character. The multiport will now return to the main configuration menu (see Section 6.3.2).

6.3.9

528ESP, 5218ESP MODELS - SET DATA BLOCK LENGTH

By responding to the Enter Request: message at the end of the main configuration menu for the 528ESP or 5218ESP with a "3" (Set Data Block Length), you may change the maximum length of the data block transmitted to the host device. The multiport will respond with: Current Block Length is ...............32 Enter Block Length (1 to 250): Enter the number of characters that you wish as a maximum length for the data block. The multiport will respond with: Save Changes Permanently? (Y/N): 47

Page 54

If you enter "Y" (yes), the change will be saved in non-volatile memory and the multiport will subsequently power-up with the change(s) in effect. If you enter "N" (no), the change will be stored in RAM, and on the next power-up, the multiport will revert to the previous configuration. The multiport will now return to the main configuration menu (see Section 6.3.3).

6.3.10

ALL 528/5218 AP, AC11P, ESP MODELS SET XON/XOFF HANDSHAKING

By responding to the Enter Request: message at the end of the main configuration menu with "4" for the 528/5218AP or with "5" for the 528/5218AC11P or 528/5218ESP (Set Xon/Xoff Handshaking), you may enable or disable XON/XOFF. NOTE: CTS/DTR handshaking will be in effect regardless of whether XON/XOFF is enabled or disabled. The multiport will respond with: Xon/Xoff handshaking is ...............(OFF) Xon/Xoff handshaking? (Y/N): You should enter "Y" (yes) if you want XON/XOFF handshaking enabled on all ports. You should enter "N" (no) if you want XON/XOFF disabled on all ports. The multiport will respond with: Save Changes Permanently? (Y/N): If you enter "Y" (yes), the change will be saved in non-volatile memory, and the multiport will subsequently power-up with the change in effect. If you enter "N" (no), the change will be stored in RAM only and will be lost upon power-down. The multiport will now return to the main configuration menu.

6.3.11

EXIT

By responding to the Enter Request: message at the end of the main configuration menu with "X" (exit), you may exit the configuration mode and return to the operation mode.

48

Page 55

6.4

525FP AND 528FP - CONFIGURATION PROCEDURE

All configuration changes must be made through the host port. This is Port 5 on the 525FP and Port 9 on the 528FP. To access the configuration mode of the multiport, connect a terminal (or a PC running a terminal emulation program) to the host port. Send from this device the current sign-on/sign-off character (factory default is Control-T) followed by ASCII capital C (43 Hex). NOTE: For illustration purposes, we will use the 528FP's configuration menus. The only differences between models is the actual number of ports shown, the title block preceding the configuration options, and noted differences.

6.4.1

MAIN CONFIGURATION MENU

The multiport will respond to the receiving of the sign-on/sign-off character and Capital C with an identification block and a menu of the configuration options available, similar to the following which applies to the 528FP: Bay Technical Associates Model 528F Multiport Controller Copyright 1983, 1986, 1987 Revision 2.08 Configuration status......…....1 Port configuration..................2 Output message strings..........3 Sign-on/sign-off character.....4 Exit .............................……....X Enter request(1-4,X):

6.4.2

STATUS

By responding to the Enter Request(1-4,X): message at the end of the configuration menu with "1" (Configuration status), you may review the current configuration of the multiport. Note: This status is not to be confused with the port connection status (see Section 5.1.4). The multiport will respond with:

49

Page 56

Port 1 2 3 4 5 6 7 8 9

Baud Rate 9600 9600 9600 9600 9600 9600 9600 9600 9600

Word Size 8 8 8 8 8 8 8 8 8

Stop Bits 1 1 1 1 1 1 1 1 1

Pariity None None None None None None None None None

Xon/ Xoff Off Off Off Off Off Off Off Off Off

Hit any key to continue Current Sign-on/sign-off character is: 14H Output messages On-line message : ^M^JOn line^G^M^J Off-line message: ^M^JOff line^M^J Busy message : ^M^JBusy^M^J Hit any key to continue Configuration status..……....1 Port configuration.......……...2 Output message strings…......3 Sign-on/sign-off character….4 Exit ...........………….............X Enter request(1-4,X): You may now make whatever changes are necessary by responding to the above menu. The Exit function will return you to the Operations mode.

6.4.3

PORT CONFIGURATION

By responding to the Enter Request(1-4,X): message at the end of the configuration menu with "2" (Port configuration), you may change the baud rate, word size, stop bits and parity and also enable or disable XON/XOFF for each port. Each port is configured individually, allowing the user to mix devices of different configurations. The multiport will respond with: Enter the port number(0-9,X): Enter the number of the port that you wish to reconfigure, followed by Carriage Return. If you enter "0" (zero), you may review the configuration status of all ports. 50

Page 57

If, for example, you entered "3" and Carriage Return, the multiport will respond with the current configuration status of Port 3 and a menu of the available options:

Baud Rate 9600

Word Size 8

Port 1

Exit/Save………..1 Set Baud rate……2 Set Word Size…..3

Stop Bits 1

Pariity None

Xon/ Xoff Off

Set Stop Bits……...4 Set Parity…………5 Set XON/XOFF…..6

Enter request: You may now reconfigure Port 3 by selecting the appropriate option (1-6) from the menu. For example, to change the baud rate to 2400 baud, send character "2" (Set baud rate). The multiport will respond with this menu: 1 2 3 4 5 6 7 8

For For For For For For For For

110 135 300 600 1200 2400 4800 9600

Enter: NOTE: If you are configuring a 525FP, this configuration menu will show different choices for baud rates with 19,200 being the maximum. Please see Section 2 for a list of supported baud rates for the 525FP. Send "6" for 2400 baud rate, and the multiport will respond with the reconfigured status of the port: Port 1

Baud Rate 9600

Word Size 8

Stop Bits 1

Pariity None

Xon/ Xoff Off

Exit/Save......1 Set Stop Bits....4 Set Baud rate..2 Set Parity.......5 Set Word size..3 Set XON/XOFF.....6 Enter request: You may now proceed to make whatever other changes are necessary for Port 3. 51

Page 58

If there are no other changes for this port, send " 1" (Exit/Save), and the multiport will respond with: Save permanently? (Y/N): NOTE: When changing the configuration of the host port, the multiport will also respond with: Change Host Device to NEW Configuration Before Answering This Request. Change the host device's serial parameters to match the new configuration of the host port before answering "Y" (yes) or "N" (no). If you answer the Save permanently? (Y/N): prompt with "Y" (yes), the new configuration for that port will be stored permanently in non-volatile memory, and the multiport will subsequently power-up at that configuration. If you answer "N" (no), the new configuration will be stored in RAM, and on the next power-up, the multiport will revert to the previous configuration. The multiport will now return to the main configuration menu (see Section 6.4.1).

6.4.4

OUTPUT MESSAGE STRINGS

By responding to the Enter request(1-4,X): message at the end of the configuration menu with "3" (Output message strings), you may change the on-line, off-line and busy messages that the multiport sends to a device. The multiport will respond with: On line message...….......1 Off line message..….......2 Busy message….....…....3 Return to main menu......X Enter request(1-3,X): NOTE: The "On line" message indicates the message sent from the multiport to a device requesting connection. The "Off line" message indicates the message sent from the multiport to a device requesting disconnection. The "Busy" message indicates the message sent from the multiport to a device requesting connection when the requested port is busy.

52

Page 59

Enter the number (1-3) of the message that you wish to change. For example, if you enter "1" (On line message), the multiport will respond with: Current message: ^M^JOn line^G^M^J Modify (Y/N)? : NOTE: The ^ symbol represents a control character. ^M or OD Hex indicates line feed. ^J or 0A Hex indicates carriage return. ^G or 07 Hex indicates a warning bell. If you enter a "N" (no), the current message will be retained, and the multiport will return you to the Output Message Strings menu. If you enter a "Y" (yes), the multiport will respond with: Enter characters in hex notation or by an ASCII string (32 characters maximum, 00H-FEH, FFH-End or 'string'): Current character: ODH Enter character or string: The multiport will prompt you character by character until the message is completed. Enter the character or string that you wish. Characters may be entered by sending two ASCII Hex characters (00-FF Hex), followed by a Carriage Return. A string may also be entered, but it must be delimited by apostrophes at the beginning and at the end of the string, followed by a Carriage Return. NOTE: If you wish to have no message sent, enter an FF Hex only, which programs no characters into that message. When you are finished, you must enter FF Hex to terminate the configuration of the on-line message. The multiport will respond with: Save permanently? (Y/N): If you enter "Y" (yes), the new message will be saved in non-volatile memory, and the multiport will subsequently power-up with the new message in effect. If you enter "N" (no), the new message will be stored in RAM, and on the next power-up, the multiport will revert to the previous message. The multiport will then return you to the Output Message Strings menu. If you wish to change another message, answer the Enter request (1-3,X): prompt with the appropriate number. If you do not wish to make additional changes, enter an "X" (Return to main menu), and the multiport will return you to the main configuration menu (see Section 6.4.1).

53

Page 60

6.4.5

SIGN ON/SIGN OFF CHARACTER

By responding to the Enter request(1-4, X): message at the end of the configuration menu with a "4" (Sign-on/sign-off character), you may change the sign-on/sign-off character to a user-defined character. The multiport will respond with: Current Sign-on/Sign-off character is: 14H Modify (Y/N)? : If you enter a "N" (no), the current sign-on/sign-off character will be retained, and the multiport will return to the main configuration menu (see Section 6.4.1). If you enter a "Y" (yes), the multiport will respond with: Remember, sign-off als o requires a carriage return to complete the disconnect sequence. Enter the new character in hex format(00H-7FH): Enter the new sign-on/sign-off character that you want in hex. Any single-digit character from 01 Hex to 7F Hex may be selected. The multiport will respond with: Save permanently? (Y/N): CAUTION: BayTech advises you to log your new sign-on/sign-off character. If it is forgotten, you will be unable to control the unit or access the configuration mode. SIGN-ON/SIGN-OFF CHARACTER_____________DATE_______BY______ SIGN-ON/SIGN-OFF CHARACTER_____________DATE_______BY______ SIGN-ON/SIGN-OFF CHARACTER_____________DATE_______BY______ If you enter "Y" (yes), the new sign-on/sign-off character will be saved in non-volatile memory, and the multiport will subsequently respond to that character only. If you enter "N" (no), the new sign-on/sign-off character will be stored in RAM, and on the next power-up, the multiport will revert to the previous sign-on/sign-off character. The multiport will now return to the main configuration menu (see Section 6.4.1).

6.4.6

EXIT

To exit the configuration mode, send an "X", and the multiport will return to the operating mode. 54