Page 41

TABLE C - 528 HOST PORT DIP-SWITCH SETTINGS Baud Rate

Switch A1

Switch A2

Switch A3

110

Off

Off

Off

135

Off

Off

On

300

Off

On

Off

600

Off

On

On

1200

On

Off

Off

2400

On

Off

On

4800

On

On

Off

9600

On

On

On

Word Size

Switch A5

8 Bits

On

7 Bits

Off

Stop bits

Switch A6

2

On

1

Off

Parity

Switch A7

Enable

On

Disable

Off

Parity

Switch A8

Odd

Off

Even

On

35

Page 42

6.2.2

PERIPHERAL PORT CONFIGURATION

The peripheral ports of the non-programmable 528 units may be configured via DIP switch settings or by software configuration. NOTE: Only the baud rate for the peripheral ports may be configured by DIP switch settings. You are given four possible baud rate selections using this method: 300, 1200, 4800, and 9600. If you wish to reconfigure the baud rate to a value other than the four specified or if you wish to change the word size, stop bits, or parity, you must use the software method. NOTE: If you change the baud rate for any of the peripheral port by using DIP switch settings, the multiport will power up with those baud rates in effect. If you change any serial port settings using the software method, the changes will be lost when the multiport is powered off. Peripheral Port Configuration Using DIP Switches If you wish to reconfigure the peripheral ports using DIP switch settings, use the following procedure: 1) 2) 3) 4) 5) 6)

36

Turn off the power switch and disconnect the AC power cord; Lift the cover of your 528 unit by removing the screw in each corner; Locate the DIP-switches on the back panel. DIP switch banks B and C are used to configure the peripheral ports. Consult Table D to determine the correct settings of the DIP-switch banks B and C. Replace Cover; Peripheral port configuration is now complete. The 528 will read the positions of the DIP-switches upon power-up.

Page 43

TABLE D 528 PERIPHERAL PORT BAUD RATE DIP-SWITCH SETTINGS Port 1

Port 2

Port 3

Port 4

Switch

Switch

Switch

Switch

Baud Rate

B1

B2

B3

B4

B5

B6

B7

B8

300

Off

Off

Off

Off

Off

Off

Off

Off

1200

Off

On

Off

On

Off

On

Off

On

4800

On

Off

On

Off

On

Off

On

Off

9600

On

On

On

On

On

On

On

On

Port 5

Port 6

Port 7

Port 8

Switch

Switch

Switch

Switch

Baud Rate

C1

C2

C3

C4

C5

C6

C7

C8

300

Off

Off

Off

Off

Off

Off

Off

Off

1200

Off

On

Off

On

Off

On

Off

On

4800

On

Off

On

Off

On

Off

On

Off

9600

On

On

On

On

On

On

On

On

528 Peripheral Port Software Configuration To access the software configuration mode of the 528 multiport, connect a dumb terminal (or a PC running a terminal emulation program) to the host port, Port 9. To review the configuration of all peripheral ports on the Model 528, send from the Host Port an ASCII Control-T followed by a capital "K". To reconfigure peripheral Port 1, send a Control-T followed by an "A"; to reconfigure peripheral Port 2, send a Control-T followed by a "B"; ...; to reconfigure peripheral Port 8, send a Control-T followed by a "H".

6.2.2.1

528 PERIPHERAL PORT - STATUS

The 528 will respond to the receiving of Control-T followed by capital K with a table similar to the following which shows the current serial port configuration for the peripheral ports: 37

Page 44

Bay Technical Associates Model 528 Port Expander, Rev. x.xx Copyright 198x CURRENT PORT CONFIGURATION PORT

BAUD RATE

WORD SIZE

STOP BITS

PARITY

1

9600

8

1

NONE

2

9600

8

1

NONE

3

9600

8

1

NONE

4

9600

8

1

NONE

5

9600

8

1

NONE

6

9600

8

1

NONE

7

9600

8

1

NONE

8

9600

8

1

NONE

If the current port configuration does not match your application, then you must reconfigure the appropriate peripheral port as described in Section 6.2.2.2.

6.2.2.2

528 PERIPHERAL PORT - SET SERIAL PORT CONFIGURATION

You may reconfigure individual peripheral ports by sending ASCII Control-T followed by ASCII Capital A, B, C , D, E, F, G, or H for peripheral ports 1 through 8 respectively. The 528 will respond to the receiving of Control-T and the appropriate peripheral port letter with a current status of that peripheral port and a list of options. For example, if you wish to reconfigure peripheral Port 3, send Control-T followed by "C". The 528 will respond back with the following menu:

38

Page 45

CURRENT PORT CONFIGURATION PORT

BAUD RATE

WORD SIZE

STOP BITS

PARITY

3

9600

8

1

NONE

QUIT....……….............1 SET BAUD RATE........2 SET WORD SIZE.........3

SET STOP BITS.....4 SET PARITY.….....5

ENTER REQUEST: You may now reconfigure Port 3 by selecting the appropriate option (1-5) from the menu. For example, to change the baud rate to 300 baud, send character 2 (set baud rate). The 528 will respond with the following menu: 1 FOR 110 2 FOR 135 3 FOR 300 4 FOR 600 5 FOR 1200 6 FOR 2400 7 FOR 4800 8 FOR 9600 ENTER REQUEST: NOTE: A colon (:) always precedes a request for data from the 528 unit. Send a "1" for 300 baud rate and the 528 will respond with the following menu: CURRENT PORT CONFIGURATION PORT

BAUD RATE

WORD SIZE

STOP BITS

PARITY

3

300

8

1

NONE

QUIT....……….............1 SET BAUD RATE........2 SET WORD SIZE.........3

SET STOP BITS.....4 SET PARITY…......5

ENTER REQUEST: If there are no other changes for this port, send a "1" to exit the serial port configuration mode for Port 3 and the 528 will now return to the operations mode.

39

Page 46

6.3

ALL 525, 528(x)P, 529, AND 5218 MODELS (EXCEPT 525FP, 528FP, AND 5218FP) CONFIGURATION PROCEDURE

All configuration changes must be made through the host port. This is Port 9 on the 528 models and Port 18 on the 5218 models. To access the configuration mode of the multiport, connect a terminal (or a PC running a terminal emulation program) to the host port. Send from this device the current control character (factory default is Control-T) followed by ASCII capital C (43 Hex). NOTE: For illustration purposes, we will use the configuration menus of the 528AP, 528AC11P, 528ESP, and 529GP.

6.3.1

528AP, 5218AP - MAIN CONFIGURATION MENU

The multiport will respond to the receiving of the control character and capital C with an identification block and a configuration menu of the options available, similar to the following: Bay Technical Associates Model 528A Multiport Controller Copyright 1984 Revision 2.05 Status.................................…….....1 Set Serial Port Configuration.........2 Set Control Character.....................3 Set XON/XOFF Handshaking........4 Exit .....................................………X Enter Request: NOTE: Menu selection is case sensitive. It is recommended that your keyboard be in the CAPS LOCK position.

6.3.2

528AC11P, 5218AC11P - MAIN CONFIGURATION MENU

The multiport will respond to the receiving of the control character and capital C with an identification block and a configuration menu of the options available, similar to the following:

40

Page 47

Bay Technical Associates Model 528AC11 Multiport Controller Copyright 1984 Revision 2.05 Status.......................……........…........1 Set Serial Port Configuration..……....2 Set Control Character..…….........…...3 Set Message Terminate Character.......4 Set XON/XOFF Handshaking.............5 Exit .......….…......……...........….........X Enter Request: NOTE 1: Menu selection is case sensitive. It is recommended that your keyboard be in the CAPS LOCK position. NOTE 2: In the configuration mode, some characters are displayed with a Hex notation since all combinations from 00 Hex to 7F Hex may be selected, some of which are not printable characters.

6.3.3

528ESP, 5218ESP - MAIN CONFIGURATION MENU

The multiport will respond to the receiving of the control character and capital C with an identification block and a configuration menu of the options available, similar to the following: Bay Technical Associates Model 528ES Multiport Controller Copyright 1984 Revision 2.05 Status.........….…….......…......….....1 Set Serial Port Configuration...........2 Set Data Block Length.....................3 Set Control Character.......................4 Set XON/XOFF Handshaking..........5 Exit ...................………....................X Enter Request: NOTE 1: Menu selection is case sensitive. It is recommended that your keyboard be in the CAPS LOCK position. NOTE 2: In the configuration mode, some characters are displayed with a HEX notation since all combinations from 00 Hex to 7F Hex may be selected, some of which are not printable characters. 41

Page 48

6.3.4

525GP/529GP/5218GP - MAIN CONFIGURATION MENU

The multiport will respond to the receiving of the control character and capital C with an identification block similar to the following and a menu of the configuration options available: Bay Technical Associates Model 525G Broadcast Controller Copyright 1986 Revision 2.01 Status...............................…......1 Set Port Configuration...............2 Set Control Character................3 Exit ..................................…......X Enter Request(1-3,X):

6.3.5

STATUS

By responding to the Enter Request: message at the end of the main configuration menu with "1" (Status), you may see the status of all ports and the current operation protocol. The multiport will respond with: Port 1 2 3 4 5 6 7 8 9

Baud Rate 9600 9600 9600 9600 9600 9600 9600 9600 9600

Word Size 8 8 8 8 8 8 8 8 8

Press Any Key to Continue

42

Stop Bits 1 1 1 1 1 1 1 1 1

Pariity None None None None None None None None None

Xon/ Xoff Off Off Off Off Off Off Off Off Off

Page 49

The 528AP and 5218AP will also show the following information: Control Character is .......14H XON/XOFF Handshaking is.....(Off) Status..............................…….......1 Set Serial Port Configuration........2 Set Control Character....................3 Set XON/XOFF Handshaking…...4 Exit ...............................…….........X Enter Request: The 528AC11P and 5218AC11P will also show the following information: Current Control Character is ..…...14H Current Terminate Character is .....0DH XON/XOFF Handshaking is..........(Off) Status..............................…………......1 Set Serial Port Configuration......….....2 Set Control Character..................….....3 Set Message Terminate Character........4 Set XON/XOFF Handshaking..............5 Exit ............................…………...........X Enter Request: The 528ESP and 5218ESP will also show the following information: Current Block Length is.....…........32 Current Control Character is ...…..14H XON/XOFF Handshaking is..........(Off) Status..........................………..........1 Set Serial Port Configuration...........2 Set Data Block Length.....................3 Set Control Character.......................4 Set XON/ XOFF Handshaking...…...5 Exit ..............................……….........X Enter Request:

43

Page 50

The 525G and 529G will also show the following information: Control Character is .......14H Bay Technical Associates Model 525G Broadcast Controller Copyright 1986 Revision 2.01 Status......................................1 Set Port Configuration............2 Set Control Character.............3 Exit ...................................…..X Enter Request(1-3,X):

6.3.6

SET SERIAL PORT CONFIGURATION

By responding to the Enter Request: message at the end of the main configuration menu of any unit with "2" (Set Serial Port Configuration), you may change the configuration of each port (i.e. baud rate, word size, stop bits, and parity). Each port is configured individually. The multiport will respond with: Enter Port Number (0=Exit),Return: You should then enter the number of the port that you wish to reconfigure, followed by Carriage Return. On the 528 models, this will be a single-digit number. On the 5218 models, this will be a two-digit number. For example, if you enter "3" (or "03" on a 5218 model), the multiport will respond with the current status of Port 3 and a menu of the available options:

Port 3

Baud Rate 9600

Exit/Save………1 Set baud rate…...2 Set word size…..3

Word Size 8

Stop Bits 1

Pariity None

Xon/ Xoff Off

Set stop bits…..4 Set parity……..5

Enter request: You may now reconfigure Port 3 by selecting the appropriate option (1-6) from the menu. For example, to change the baud rate to 2400 baud, send character "2" (Set baud rate). 44