Page 71

the remainder of your character string which would consist of choices selected from the following menus: A. MAIN MENU Quit....................................1 Set Baud Rate....................2 Set Word Size....................3 Set Stop Bits......................4 Set Parity...........................5 B. SET BAUD RATE 110.....................................1 135.....................................2 300.....................................3 600.....................................4 1200...................................5 2400...................................6 4800...................................7 9600...................................8 C. SET WORD SIZE 5.......................................1 6.......................................2 7.......................................3 8.......................................4 D. SET STOP BITS 1.......................................1 1 1/2.................................2 2.......................................3 E. PARITY None...................................1 Even....................................2 Odd.....................................3 To return to the verbose mode, send the multiport ASCII Control-T followed by capital "J". If no other changes are needed, you may begin operations with your multiport controller. Please see Section 6.6.6 for an example using non-verbose mode.

6.6.6

NON-VERBOSE MODE EXAMPLE

As an example, we will show how to configure a 528AP multiport controller using nonverbose mode. Please refer to Section 6.6.3.1 for a listing of configuration menus for this example. Please refer to the appropriate subsection for the non-verbose mode 65

Page 72

configuration menus and the control character sequence to program your multiport in non-verbose mode (i.e., Control-R followed by "5" or Control-T followed by "I"). Suppose you wish to reconfigure the 528AP multiport controller to have Port 2's serial parameters to 300 baud, 7 word size, 2 stop bits, even parity, reconfigure the control character to Control-T, and enable XON/XOFF handshaking, you would send the following ASCII character string: ^TI^TC222333435213144YX. This breaks down as follows: ^T indicates Control-T I indicates non-verbose mode ^T indicates Control-T C indicates Configuration Mode. 2 indicates Set Serial Port Configuration. 2 indicates Port 2. 2 indicates Set baud rate. 3 indicates 300 baud. 3 indicates Set word size. 3 indicates 7 word size. 4 indicates Set stop bits. 3 indicates 2 stop bits. 5 indicates Set parity. 2 indicates Even parity. 1 indicates Exit to Main Menu. 3 indicates Set Control Character. 14 indicates 14HEX - Control-T. 4 indicates Set Xon/Xoff Handshaking. Y indicates Xon/Xoff enabled. X indicates Exit to Operation Mode.

66

Page 73

7

MAINTENANCE

Since there are no adjustments and no moving parts in the 500 Series, preventive maintenance is unnecessary.

7.1

RETURNS TO THE FACTORY

If your Bay Tech unit needs service, upgrade, or repair, return it to BayTech. Before dismantling your equipment or before returning the unit for any reason, always call BayTech. The user should never attempt repairs on this unit. If you need to return the unit to the factory for repair, warranty work, or upgrade, follow the instructions below for repackaging and shipping.

7.2

REPACKING FOR SHIPPING a. Call BayTech to get a Return Authorization Number. IMPORTANT: Without this number, BayTech will not accept returns.

b. Use the original packaging if available or choose a heavy cardboard box. c. Surround your unit with a minimum of two inches of insulation.

d. Be sure to seal the box securely with strapping or packing tape. We do not recommend masking tape or cellophane tape. e. On the outside of the box, please write the Return Authorization Number. f. Ship the unit to the following address: Bay Technical Associates, Inc. 200 N. Second Street Bay St. Louis, MS 39520-1000, USA

67

Page 74

8

TECHNICAL SUPPORT/ORDERING

In the event that you have problems with the multiport controller, BayTech has a staff of applications engineers on duty to assist you from 7 am to 6 pm (CST or CDT), Monday through Friday. When you call BayTech Technical Support, please have the following information available to help the applications engineers answer your questions more accurately and more quickly: 1.

Identify{ which modules you are using and have the serial number (located on the back of the unit) handy.

2.

Identify what computers, peripherals or other peripherals you have connected to multiport controller.

3.

Identify any special equipment you are using (for example, in-line spoolers, networks, software drivers, etc.).

4.

Identify what cables you are using, what the lengths of the cables are, and who sold you the cables.

5.

Identify any special options you may have ordered with your multiport controller.

6.

Identify the software packages you are using.

7.

If possible, have a print-out of the multiport controller's configuration status ready when you call. Bay Technical Associates, Inc. P.O. Box 387, 200 N. Second Street Bay Saint Louis, Mississippi 39520 U.S.A. Phone: 228/467-8231 or 800/523-2702 Fax: 228-467-4551 Web Site: www.baytechdcd.com

68

Page 75

9

FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFACE STATEMENT*

This equipment generates and uses radio frequency energy and, if not installed and used properly (that is, in strict accordance with the manufacturer's instructions) may cause interference to radio and television reception. The equipment has been type tested and found to comply within the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference to radio or television reception will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures. 1.

Reorient the receiving antenna.

2.

Relocate the computer equipment with respect to the receiver.

3.

Move the computer away from the receiver.

4.

Plug the computer into a different outlet so that computer and receiver are on different branch circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The Federal Communications Commission has prepared a booklet entitled "How to Identify and Resolve Radio - TV Interference Problems" which may be helpful to you. This booklet (stock #004-000-00345-4) may be purchased from the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402. *Use of a shielded interface cable is required to comply within the Class A limits in Subpart J of Part 15 of FCC rules

69

Page 76

INDEX A A Series, 3, 7, 15, 20 AC11 Series , 4, 8, 15, 22 Application, 3, 4, 5, 6, 7 ASCII, 3, 4, 5, 6, 7, 16, 19, 20, 23, 29, 31, 32, 37, 38, 40, 49, 53, 55, 57, 58, 59, 60, 62, 63, 64, 65, 66 Asynchronous , 8

B Baud rate, 8, 51 Break condition, 17 Broadcast, 42, 44 Buffer, 10 Busy message, 19, 23, 50, 52

C Cabling, 1 CAPS LOCK, 40, 41 CCITT, 8 Configuration, 9, 31, 34, 36, 37, 40, 41, 42, 43, 44, 45, 49, 50, 52, 57, 61, 62, 63, 66 Configuration status , 49, 50 Connectors , 9 Control character, 8, 9, 11 Control-T, 3, 5, 6, 7, 8, 9, 11, 15, 16, 17, 19, 20, 21, 22, 31, 32, 37, 38, 40, 49, 55, 56, 59, 60, 62, 63, 64, 65, 66

D Data block length, 8, 9, 11 Data Communication Equipment, 13 Data Terminal Equipment, 13 DCE, 10, 13, 14 Desk-top, 10 DIP-switch, 8, 34, 36 Disconnect, 9, 19 DSR, 13, 24 DTE, 9, 13, 14 DTR, 10, 13, 24, 25, 26, 48

E EIA-232, 6, 9, 13 EIA-422, 10 ES Series , 5, 11, 15, 18, 22

Exit, 40, 41, 42, 43, 44, 45, 49, 50, 51, 52, 58, 59, 61, 62, 63, 66

F F Series, 6, 8, 11, 15 Factory default, 21, 22, 23 Federal Communications Commission, 69

G G Series, 7, 15, 20 GND, 14

H Handshaking, 40, 41, 43, 48, 61, 62, 63, 64, 66 HEX notation, 41 Host port, 27, 34

I IBM, ii, 13, 15 Installation, 1 Interference, 69

L LED, 10, 11, 20 LEDs , 10

M Maintenance, 1 Menu, 31, 33, 40, 41, 57, 66

N Network, 55 Non-programmable, 31 Non-verbose mode, 59, 60, 64

O Off line message, 19, 23, 52 On line message, 23, 52, 53 Output message strings , 49, 50, 52 Output messages , 50

Page 77

P Parity, 8, 28, 35, 51, 58, 59, 65 Peripheral ports, 12 Power-on, 11

T Terminal, 24, 25 Terminating character, 8 Tx, 10, 14

R RAM, 31, 33, 46, 47, 48, 52, 53, 54, 57 RTS, 13, 24 RX, 13, 58

S SGND, 13 Signal ground, 13 Sign-on/sign-off character, 49, 50, 54 Specifications, 1 Status, 40, 41, 42, 43, 44, 61, 62, 63 Stop bits, 8, 35

V VAC, 9, 10, 11

W Word size, 8, 51

X XON/XOFF, 3, 4, 5, 6, 7, 8, 9, 10, 11, 21, 22, 23, 24, 25, 26, 40, 41, 43, 45, 48, 50, 51, 61, 63, 64, 66 XON/XOFF handshaking, 3, 4, 5, 6, 7, 9, 21, 22, 23, 25, 45, 48, 66

71