Using the ArgoxScan 8110/8120/8150/8250/8310/8312: All Scanner Manual PN 49-81101-008.pdf, pages 65 to 74
Pages 65 to 74 of 123, from Using the ArgoxScan 8110/8120/8150/8250/8310/8312
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Argox AS-8150
Page 65
Industrial 2 of 5 Read: Format Data Digits (Variable)
Checksum (Optional)
Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
00-64
00-64
Read
00 Max. code length 00-64
00-64 00
Min. code length
60
Page 66
0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<i>
00-44
00-44
Code ID setting
00
Insert group number selection
Exit
61
Page 67
Matrix 2 of 5 Eur Read: Format Data Digits (Variable)
Checksum (Optional)
Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
Enable
01
Read
Checksum Verification
62
Page 68
Disable
00
Enable
01
00-64
00-64
Checksum Transmission
00 Max. code length 00-64
00-64
00 Min. code length 0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<B>
00-44
00- 44
Code ID setting
00
Insert group number selection
Exit
63
Page 69
Codabar Read: Format Start
Data Digits (Variable)
Checksum (Optional) End
Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
(8120/8150/8250 /8310/8312)
Read
Enable
01
Disable
00
Enable
01
Checksum Verification
64
(8110)
Page 70
Disable
00
Enable
01
00-64
00-64
Checksum Transmission
00 Max. code length 00-64
00-64
00 Min. code length 0-15
00-15
00 Truncate leading 0-15
00-15 00
Truncate ending 00-ffH ASCII
00-ffH code
<%>
Code ID setting
Exit
65
Page 71
Codabar Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39.
Program Option Bar Code
Option
Alphanumeric Entry
00-44
00-44 00
ABCD/ABCD
00 abcd/abcd
01
ABCD/TN*E
02
Abcd/tn*e
03
Disable
00
Enable
01
Insert group number selection
Start/End type
Start/End transmission
Exit
66
Page 72
Code-128 Read: Format Data Digits (Variable)
Checksum (Optional)
Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
Enable
01
Disable
00
Enable
01
Read
Checksum Verification
Checksum Transmission
Exit
67
Page 73
Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to “]C1”,and next to be a field separator code as <GS>(1D16). ]C1
Data
<GS> Data
Checksum
Program Option Bar Code
Option
Alphanumeric Entry
00-64
00-64
00 Max. code length 00-64
00-64 00
Min. code length
68
Page 74
0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<#>
00-44
00-44
Code ID setting
00
Standard
00
UCC/EAN-128
01
Insert group number selection
Format
Exit
69