Page 55
EAN-8 Read: Format Data Digits (7 Digits)
Check Digits
Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
Enable
01
0-15
00-15
Read
Check-sum transmission
00 Truncate leading
50
Page 56
0-15
00-15 00
Truncate ending
Code ID setting
Two characters
00-ffH, 00-ffH
00-ffH ASCII
< FF > code 00-44
00-44 00
Insert group number selection
Exit
51
Page 57
EAN-8 Supplement digits: Format Data Digits (7 Digits)
Check Digits
Supplement Digits 2 or 5 or UCC/EAN 128
Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE.
Program Option Bar Code
Option
Alphanumeric Entry
None
00
2 digits
01
5 digits
02
UCC/EAN 128
03
Auto detection
04
None
00
2 digits
01
Supplement digits
5 digits
02
(For 8120/8310/8312)
2,5 digits
03
UCC/EAN 128
04
2, UCC/EAN 128
05
5, UCC/EAN 128
06
All
07
Supplement digits (For 8110/8150/8250)
52
Page 58
Disable
00
Enable
01
None
00
Truncate leading
01
Truncation / Expansion (For 8110)
Truncation / zero
Expansion
Expand to EAN13
02
Disable
00
Enable
01
(For 8120/8150/8250 /8310/8312)
Expansion
Exit
53
Page 59
Code 39 Read: Format Start “ ”
"
Data Digits ( Variable)
Checksum (Optional)
End “ ”
"
Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symbology will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Read
54
Page 60
Disable
00
Enable
01
Disable
00
Enable
01
00-64
00-64
Check-sum verification
Check-sum transmission
00 Max. code length 00-64
00-64
00 Min. code length 0-20
00-20
00 Truncate leading 0-15
00-15 00
Truncate ending 00-ffH ASCII
00-ffH code
<
>
Code ID setting
Exit
55
Page 61
Code 39 Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix. When a symbol was decoded without the appended code, the data will be transmitted without Code ID and Prefix, but the Postamble Suffix codes are appended. This function is used when the first number of code 39 is a space. Example: 123456.
#
Start/end transmission: The start and end characters of Code-39 are“ ”. You can transmit all data digits including two “ ”.
"
"
Program Option Bar Code
Option
Alphanumeric Entry
00-44
00-44 00
Insert group number selection
56
Page 62
Standard
00
Full ASCII
01
Disable
00
Enable
01
Disable
00
Enable
01
Format
Append
Start/end transmission
Exit
57
Page 63
Interleaved 2 of 5 Read: Format Data Digits (Variable)
Checksum (Optional)
Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
Enable
01
Read
Check-sum verification
58
Page 64
Disable
00
Enable
01
00-64
00-64
Check-sum transmission
00 Max. code leading 00-64
00-64
00 Min. code leading 0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<i>
00-44
00-44
Code ID setting
00
Insert group number selection
Exit
59