Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 13

Using the ArgoxScan 8110/8120/8150/8250/8310/8312: All Scanner Manual PN 49-81101-008.pdf, pages 55 to 64

Pages 55 to 64 of 123, from Using the ArgoxScan 8110/8120/8150/8250/8310/8312

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Argox AS-8150

Page 55

EAN-8 Read: Format Data Digits (7 Digits)

Check Digits

Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

Disable

00

Enable

01

0-15

00-15

Read

Check-sum transmission

00 Truncate leading

50

Page 56

0-15

00-15 00

Truncate ending

Code ID setting

Two characters

00-ffH, 00-ffH

00-ffH ASCII

< FF > code 00-44

00-44 00

Insert group number selection

Exit

51

Page 57

EAN-8 Supplement digits: Format Data Digits (7 Digits)

Check Digits

Supplement Digits 2 or 5 or UCC/EAN 128

Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE.

Program Option Bar Code

Option

Alphanumeric Entry

None

00

2 digits

01

5 digits

02

UCC/EAN 128

03

Auto detection

04

None

00

2 digits

01

Supplement digits

5 digits

02

(For 8120/8310/8312)

2,5 digits

03

UCC/EAN 128

04

2, UCC/EAN 128

05

5, UCC/EAN 128

06

All

07

Supplement digits (For 8110/8150/8250)

52

Page 58

Disable

00

Enable

01

None

00

Truncate leading

01

Truncation / Expansion (For 8110)

Truncation / zero

Expansion

Expand to EAN13

02

Disable

00

Enable

01

(For 8120/8150/8250 /8310/8312)

Expansion

Exit

53

Page 59

Code 39 Read: Format Start “ ”

"

Data Digits ( Variable)

Checksum (Optional)

End “ ”

"

Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symbology will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

Read

54

Page 60

Disable

00

Enable

01

Disable

00

Enable

01

00-64

00-64

Check-sum verification

Check-sum transmission

00 Max. code length 00-64

00-64

00 Min. code length 0-20

00-20

00 Truncate leading 0-15

00-15 00

Truncate ending 00-ffH ASCII

00-ffH code

<

>

Code ID setting

Exit

55

Page 61

Code 39 Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code (space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix. When a symbol was decoded without the appended code, the data will be transmitted without Code ID and Prefix, but the Postamble Suffix codes are appended. This function is used when the first number of code 39 is a space. Example: 123456.

#

Start/end transmission: The start and end characters of Code-39 are“ ”. You can transmit all data digits including two “ ”.

"

"

Program Option Bar Code

Option

Alphanumeric Entry

00-44

00-44 00

Insert group number selection

56

Page 62

Standard

00

Full ASCII

01

Disable

00

Enable

01

Disable

00

Enable

01

Format

Append

Start/end transmission

Exit

57

Page 63

Interleaved 2 of 5 Read: Format Data Digits (Variable)

Checksum (Optional)

Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

Disable

00

Enable

01

Read

Check-sum verification

58

Page 64

Disable

00

Enable

01

00-64

00-64

Check-sum transmission

00 Max. code leading 00-64

00-64

00 Min. code leading 0-15

00-15

00 Truncate leading 0-15

00-15

00 Truncate ending 00-ffH ASCII

00-ffH code

<i>

00-44

00-44

Code ID setting

00

Insert group number selection

Exit

59