For the Argox AS-8150

Page 75

Code-128 Append: When the function is enabled, it won' t show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn' t have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is <GS>(1D16).

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

00-ffH ASCII

00-ffH code

<#>

00-ffH ASCII

00-ffH code

1DH

Append

UCC/EAN-128 ID setting

Field separator code

Exit

70

Page 76

Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.

Program Option Bar Code

Option

Alphanumeric Entry 00

Enable

01

Disable

00

Enable

01

Disable

00

Enable

01

Disable

Read

Checksum

(two digits)

Verification

Checksum Transmission

Exit

71

Page 77

Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

00-64

00-64

00 Max. code length 00-64

00-64

00 Min. code length 0-15

00-15

00 Truncate leading 0-15

00-15 00

Truncate ending

72

Page 78

00-ffH ASCII

00-ffH code

<&>

00-44

00-44

Code ID setting

00

Insert group number selection

Exit

73

Page 79

Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

Disable

00

One digit

01

Two digits

02

Read

Checksum Verification

74

Page 80

Disable

00

Enable

01

00-64

00-64

Checksum Transmission

00 Max. code length 00-64

00-64

00 Min. code length 0-15

00-15

00 Truncate leading 0-15

00-15

00 Truncate ending 00-ffH ASCII

00-ffH code

<O>

00-44

00-44

Code ID setting

00

Insert group number selection

Exit

75

Page 81

MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

Disable

00

Mod 10

01

Read

Checksum Verification

(8110) (8120/8150/8250 /8310/8312)

Mod 10/10

76

02

Page 82

Mod 11/10

03

Disable

00

Enable

01

00-64

00-64

Checksum Transmission

00 Max. code length 00-64

00-64

00 Min. code length 0-15

00-15

00 Truncate leading 0-15

00-15

00 Truncate ending 00-ffH ASCII

00-ffH code

<@>

00-44

00-44

Code ID setting

00

Insert group number selection

77

Exit

Page 83

UK/plessey Read: Format Data Digits (Variable)

Checksum1+2 (Optional)

Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.

Program Option Bar Code

Option

Alphanumeric Entry

Disable

00

Enable

01

Disable

00

Enable

01

Read

Checksum Verification

78

Page 84

Disable

00

Enable

01

00-64

00-64

Checksum Transmission

00 Max. code length 00-64

00-64

00 Min. code length 0-15

00-15

00 Truncate leading 0-15

00-15

00 Truncate ending 00-ffH ASCII

00-ffH code

<@>

00-44

00-44

Code ID setting

00

Insert group number selection

Exit

79