Page 75
Code-128 Append: When the function is enabled, it won' t show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn' t have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is <GS>(1D16).
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
00-ffH ASCII
00-ffH code
<#>
00-ffH ASCII
00-ffH code
1DH
Append
UCC/EAN-128 ID setting
Field separator code
Exit
70
Page 76
Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Program Option Bar Code
Option
Alphanumeric Entry 00
Enable
01
Disable
00
Enable
01
Disable
00
Enable
01
Disable
Read
Checksum
(two digits)
Verification
Checksum Transmission
Exit
71
Page 77
Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
00-64
00-64
00 Max. code length 00-64
00-64
00 Min. code length 0-15
00-15
00 Truncate leading 0-15
00-15 00
Truncate ending
72
Page 78
00-ffH ASCII
00-ffH code
<&>
00-44
00-44
Code ID setting
00
Insert group number selection
Exit
73
Page 79
Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
One digit
01
Two digits
02
Read
Checksum Verification
74
Page 80
Disable
00
Enable
01
00-64
00-64
Checksum Transmission
00 Max. code length 00-64
00-64
00 Min. code length 0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<O>
00-44
00-44
Code ID setting
00
Insert group number selection
Exit
75
Page 81
MSI/plessey Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
Mod 10
01
Read
Checksum Verification
(8110) (8120/8150/8250 /8310/8312)
Mod 10/10
76
02
Page 82
Mod 11/10
03
Disable
00
Enable
01
00-64
00-64
Checksum Transmission
00 Max. code length 00-64
00-64
00 Min. code length 0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<@>
00-44
00-44
Code ID setting
00
Insert group number selection
77
Exit
Page 83
UK/plessey Read: Format Data Digits (Variable)
Checksum1+2 (Optional)
Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 36 Insertion group number selection of UPCA.
Program Option Bar Code
Option
Alphanumeric Entry
Disable
00
Enable
01
Disable
00
Enable
01
Read
Checksum Verification
78
Page 84
Disable
00
Enable
01
00-64
00-64
Checksum Transmission
00 Max. code length 00-64
00-64
00 Min. code length 0-15
00-15
00 Truncate leading 0-15
00-15
00 Truncate ending 00-ffH ASCII
00-ffH code
<@>
00-44
00-44
Code ID setting
00
Insert group number selection
Exit