The text of a manual · part 3 of 4
M5000 Portable Data Terminal, pages 21 to 30
Pages 21 to 30 of 38
The original document is the PDF (789 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the AML M5000
Page 21
M5000 Portable Data Terminal
American Microsystems, Ltd.
Data - select one of the following options. (Default is Menu.) Menu - allows you to select specific data files for transmission. Send All - transmits all data files stored and avoids the Upload Selection menu.
Mode - specifies which mode is automatically used when the M5000 PDT transmits data. You are not required to specify the transmission mode each time data is transmitted (unless Menu is enabled). You are required to manually select one of the following transmission modes each time the M5000 PDT transmits data: Kbd Wedge, RS232 port or modem. (Default is Menu.)
Dialing - sets the modem for telephone dial type, either Tone (default) or Pulse. Phone Number - sets the destination telephone number for modem communications. Modem Init - sets the modem initialization string for modem communications. Modem Time Out - when checked, this setting aborts Transmit Receive mode after approximately four minutes, fifteen seconds, if a call is not received. The M5000 PDT must be connected to a modem and operating in Transmit Receive mode in order for this feature to function.
SOT Text (Start of Transmit) - During communications, (Send, Data Files) Start of Transmit text is transmitted before all other data. †Note: ASCII character values may be represented by a three character sequence of /nn (/nn being the hex value of the character). Since a slash is the start of a hex value, you must type // to output a slash. PC function keys are defined as /F1 through /F0, function key F10 is defined as /F0.
SOT Delay - defines the amount of time delay inserted between each character of the SOT Text during file transmission. The delay (increments of tenths of a second) is used to slow the data output rate so the M5000 PDT does not generate a data overrun on the host computer during transmission especially when transmitting data by the keyboard wedge. Most systems do not require a SOT Delay. EOT Text (End of Transmit) - During communications, (Send, Data Files) End of Transmit Text is transmitted after all other data. †Note: ASCII character values may be represented by a three character sequence of /nn (/nn being the hex value of the character). Since a slash is the start of a hex value, you must type // to output a slash. PC function keys are defined as /F1 through /F0, function key F10 is defined as /F0.
EOT Delay - defines the amount of time delay inserted between each character of the EOT Text during file transmission. The delay (increments of tenths of a second) is used to slow the data output rate so the M5000 PDT does not generate a data overrun on the host computer during transmission especially when transmitting data by keyboard wedge. Most systems do not require an EOT Delay.
21
Page 22
American Microsystems, Ltd.
M5000 Portable Data Terminal
Setup The following system-wide parameters are configured for the M5000 PDT when you choose Setup, in the M5000 PDT Main Menu: Date/Time, Bar Codes, Comm. Setup, Laser/CCD Options, Other Setup and Reset Setup.
Setup Selection menu Date/Time - when Date/Time is selected from the Setup Selection menu, the M5000 PDT displays the date and time in the following 24-hour format.
Set Date & Time:
01 / 05 /1 9 99
16 :1 6
MM/DD/YYYY
HH:MM
All hours past noon must be entered in military time (1300-2300). When you change the time or date, the internal clock resets seconds to zero. In order to access time only without the option to change it, choose Time from the Main Menu.
†Note: Date/Time and Non-Portable Mode options are selectable only on the M5000 PDT and cannot be modified in the M5000 Programmer.
Bar Codes Your M5000 PDT can be setup to read the most widely used bar code symbologies. Included are such options as enabling the bar code symbology, expanding symbology options to read special characters, transmitting standard check digits and enabling concatenation mode. Bar code setup options and descriptions for Code 39, UPC, EAN, UPC/EAN Add-ons, Interleaved 2 of 5, Codabar, Code 128, Code 93, MSI/Plessey and Code 11 are listed in this section.
Code 39 Options Option Decoder Full ASCII Check Digit
Setting *On *Off *Off
Send Check Concatenate
*Off *Off
Description Enables/disables reading Code 39 bar codes. Enables/disables reading Full ASCII extension of Code 39. Enables/disables mod 43 check digit. (Code 39 bar codes only containing a valid check digit can be read.) Transmits mod 43 check digit with bar code data. Enables/disables concatenate mode (see definition below.)
†Note: The concatenate mode allows the M5000 PDT to accumulate multiple Code 39 bar codes in the buffer and send them to the computer as though a single bar code. When a Code 39 bar code containing a leading space is read, the M5000 PDT beeps twice and buffers the data without transmission. This process continues until a Code 39 bar code without a leading space is read or 128 characters are buffered. A Code 39 bar code that only contains dashes can clear the buffer.
22
Page 23
M5000 Portable Data Terminal
American Microsystems, Ltd.
UPC Options Option Decoder
Setting *On
Expand UPCE
*Off
Expand UPCA
*Off
*UPCA #System *UPCE #System *UPCA Check Digit *UPCE Check Digit
*On *On *On *On
Description Enables/disables reading UPC-A & UPC-E bar codes. Converts UPC-E bar codes to UPC-A before transmission; after conversion (if on), UPC-A programming options are followed. Converts UPC-A bar codes to EAN-13 format by inserting a leading zero; after conversion (if on), EAN-13 programming options are followed. Transmits UPC-A number system character. Transmits UPC-E number system character. Transmits UPC-A check digit character. Transmits UPC-E check digit character.
EAN Options Option *Decoder
Setting *On
EAN8 Zero Fill
*Off
*EAN13 Country Code *EAN8 Country Code *EAN13 Check Digit *EAN8 Check Digit ISBN Number Convert
*On *On *On *On *Off
Description Enables/disables reading EAN-8 & EAN-13 bar codes. Adds five leading zeros to EAN-8 bar codes; after conversion, (if on), EAN-13 programming options are followed. Transmits EAN-13 Country Code. Transmits EAN-8 Country Code. Transmits EAN-13 check digit character. Transmits EAN-8 check digit character. Converts 13 digit Bookland/EAN (978 prefix) to the corresponding 10-digit ISBN number.
UPC/EAN Add-ons Options Option *Decoder
Setting *Off
*2 Digit *5 Digit UPC Supplement
*On *On *Off
EAN Supplement
*Off
Bookland Supplement
*Off
Send Space
*Off
*Notes default
23
Description Enables/disables reading UPC & EAN supplement bar code unless on is selected. Enables/disables reading 2 digit supplements. Enables/disables reading 5 digit supplements. UPC bar codes are not read unless accompanied by a valid supplement. EAN bar codes are not read unless accompanied by a valid supplement. Bookland/EAN bar codes are not read unless accompanied by a valid supplement. Inserts a space between the standard bar code data and the supplemental data.
Page 24
American Microsystems, Ltd.
M5000 Portable Data Terminal
Interleaved 2 of 5 Options Option Decoder
Setting *On
Check Digit
*None USS OPCC
Send Check
*Off
Fixed Size
*Off
Fixed Size 1 (6-60)
*6
Fixed Size 2 (0-60)
*0
Fixed Size 3 (0-60)
*0
Description Enables/disables reading Interleaved 2 of 5 bar codes. USS Check Digit and OPCC Check Digit are mutually exclusive (only one option can be selected at a time). You can toggle left or right arrow key to select option on M5000 PDT. Does not transmit Interleaved 2 of 5 check digit with bar code data. Reads fixed length I 2 of 5 bar code bar codes only matching the lengths specified in the fixed size 1, 2 and 3 options defined below. Sets the first valid fixed length for I 2 of 5. Valid lengths are 2 to 60 characters, however length must be an even number. Default fixed length is 6 characters and is disabled when set to 0 characters. Sets the second valid fixed length for I 2 of 5. Default length is set to 0 characters (the second fixed length is disabled). Sets the third valid fixed length for I 2 of 5. Default length is set to 0 characters (the third fixed length is disabled).
Codabar Options Option Decoder Start/Stop CLSI Format
Setting *On *Off *Off
CLSI Chk Digit
*Off
Description Enables/disables reading Codabar bar codes. Transmits the Codabar start/stop characters. A blank after the first, fifth and tenth characters of a 14-character Codabar bar code. Bar code length does not include the start/stop characters. Enables/disables the CLSI check digit. When enabled, all fourteen digit numeric bar codes must contain a valid check digit.
Code 128 Options Option Decoder UCC Verify
Setting *On *Off
*Send Mod 10
*On
Description Enables/disables reading Code 128 bar codes. Check for a valid mod 10 check digit. Mod 10 is not required on UCC mod 10 bar codes (applies to 20digit serial shipping container bar codes). Transmits the mod 10-check digit with the bar code data.
*Notes default
24
Page 25
M5000 Portable Data Terminal
American Microsystems, Ltd.
Code 93 Options Option Decoder Concatenate
Setting *On *Off
Description Enables/disables reading Code 93 bar codes. Enables/disables concatenate mode.
†Note: The concatenate mode allows the M5000 PDT to accumulate multiple Code 93 bar codes in the buffer and sends them to the computer as though a single bar code. When a Code 93 bar code containing a leading space is read, the M5000 PDT beeps twice and buffers the data without transmission. This process continues until a Code 93 bar code without a leading space is read or 128 characters are buffered. A Code 93 bar code bar code that only contains dashes will clear the buffer.
MSI/Plessey Options Option Decoder 2nd Check Digit
Setting *Off *Off
Mod 11 Check (Digit)
*Off
Send Check 1 Send Check 2 ISBN
*Off *Off *Off
Description Enables/disables reading MSI/Plessey bar codes. Two valid check digits are required for each bar code. The first check digit can be either mod 10 or 11, the second must always be mod 10. Determines whether mod 11 or mod 10 is used as the first check digit. Transmits the first check digit. Transmits the second check digit. Enables/disables reading Modified Plessey ISBN bar codes. (Only eleven-digit ISBN bar codes can be read.)
Code 11 Options Option Decoder 2nd Chk Digit
Setting *Off *Off
Send Check 1 Send Check 2
*Off *Off
Description Enables/disables reading Code 11 bar codes. Two valid check digits are required for each bar code. Transmits the first check digit. Transmits the second check digit.
*Notes default
Termination Char - The optional Termination Char is transmitted at the end of the bar code data and applicable only during non-portable mode operation (refer to Non-Portable Mode on page 31). Select one of the following options: None Tab (ASCII 09; hex /09) CR (carriage return, ASCII 13; hex /0D)(default) LF (line feed, ASCII 10; hex /0A) CR + LF (carriage return and line feed, ASCII 13 and ASCII 10; hex /0D/0A) User defined termination character (00H-F9H).
User Termination - valid only if the Termination Char option is set to User. Default is set to 00H.
25
Page 26
American Microsystems, Ltd.
M5000 Portable Data Terminal
Termination Override - if a control character or special character (Func, arrow, etc.) is embedded in the bar code data, the preamble, postamble and termination character is not transmitted. Default is set to off.
Preamble, is a set of user-defined characters and transmitted at the beginning of the bar code data. To define the preamble, enter ASCII characters. This option is active only during nonportable mode. This field can include 0-32 characters, alpha, numeric and all ASCII characters.
Preamble Send Delay - is an option that specifies the amount of delay occurring after the bar code preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds, default is 0.0 seconds.
Postamble, is a set of user defined characters and transmitted at the end of the bar code data. To define the postamble, enter ASCII characters. This option is active only during non-portable mode. This field can include 0-32 characters, alpha, numeric and all ASCII characters
Postamble Send Delay - is an option that specifies the amount of delay occurring after the bar code preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds, default is 0.0 seconds.
Bar Code Edit - the editing option must be checked for editing options to be operational.
Editing - enables bar code editing. Space Strip - refers to bar code leading and trailing spaces to be stripped or removed from the data. (Editing must be on.)
Leading Strip - refers to the number of bar code characters (0-30) to be stripped or removed from the beginning of the bar code data.
Trailing Strip - refers to the number of bar code characters (0-30) to be stripped or removed from the end of the bar code data. †Note: If the total number of strip characters (leading and trailing) is greater than the number of characters in the bar code, no characters are stripped.
Code - editing can either apply to all or one bar code type. The default is All bar code types.
Bar Code Beeper, when you scan a bar code the M5000 PDT emits a beep. The following settings allow you to set the tone and length of the beep.
Tone - sets the volume of the beep. Select one of the following options: None Low Medium (default) High
Length - sets the length of the beep. Select one of the following options: Shortest Short (default) Long Longest 26
Page 27
M5000 Portable Data Terminal
American Microsystems, Ltd.
Comm. Setup Refer to Communications Setup in the previous section.
Laser/CCD Options Mode - select one of the following options by using the left or right arrow: Triggera trigger pull activates the laser that remains on until the trigger is released, a valid decode occurs or a laser/CCD timeout is reached. (default) Pulsea trigger pull activates the laser that remains on until a valid decode occurs or a laser/CCD timeout is reached. Continuousa trigger pull activates the laser that remains on while the trigger is pressed or a valid decode occurs before the laser/CCD timeout is reached. Blinka trigger pull activates the laser that remains on for a period equal to the laser/CCD timeout after a valid decode occurs. The laser blinks 250ms on and 250ms off. Blink mode does not operate properly for lasers that employ thermal shutdown.
Timeoutif the laser or CCD does not read a bar code within the designated time period, the device turns off. Select off or a 1-9 second delay. (If the option is set to off, it overrides this safety feature.) (The default is a three-second timeout.) Read Delay - this option sets the delay period between successive reads of the same bar code. This allows the removal of the bar code from the scan field without multiple reads. Select one of the following options: 0.0 1.0
(no delay) – 9.9 seconds (incremented in tenths of a second) second (default)
Other Options Bar Code ID - transmits the bar code identifier character at the beginning of the bar code data. A space is included between the ID character and the bar code data. Choose Off or On to activate this option. Default is set to On.
Duplicate Reads - enables reading the same bar code multiple times. (Default is set to on.)
Read Verify # - value from 0 to 9 denoting number of rereads of same bar code before accepting it as valid data. (Default is 0.)
F1 - F10 Keys - enables reading of function keys in place of ASCII characters. (Default is set to on.)
Special Keys - enables reading of special keys in place of ASCII characters. (Default is set to on.)
27
Page 28
American Microsystems, Ltd.
M5000 Portable Data Terminal
Other Setup Timeout - sets the amount of time (1-99 minutes) the M5000 PDT remains on after the last activity, however, it is disabled while operating in keyboard wedge mode. Option is set to five minutes by default. Password - to access the Setup mode, a password must be entered. The fixed password (OK) cannot be changed. Option is off by default.
Auto Input - select Auto Input and the M5000 PDT automatically loads the first program in memory when Input is selected. If a data file or multiple data files exist for the active program, the M5000 PDT uses the first file created for that program. If a data file for the program does not exist, the M5000 PDT creates a filename FILE#1. Option is off by default. Auto Save - automatically saves the data file when you exit Input. Option is unchecked by default.
View Delay - sets the duration of the displayed characters for bar code data and lookup file entries. Default is set to 0.5s. Overwrite - bar code data automatically overwrites the contents of the current input. Option is on by default.
Halt on Err - halts when an error occurs during operation and disables the bar code reader input. The appropriate error message is displayed until a key is pressed. Option is off by default. Wedge Keypad - enables or disables keypad output during any non-portable mode operation. Option is off by default. Keypad Beep - enables or disables Keypad Beep when a key is pressed. Option is on by default.
Left Trigger - sets the M5000 PDT left trigger to the following mode using the left or right arrow: None - trigger is ignored. Alpha - trigger function is the same as pressing the alpha key on the keyboard. Laser - trigger function is the same as pressing the trigger on the laser. (default)
Right Trigger - sets the M5000 PDT right trigger to the following mode using the left or right arrow: None - trigger is ignored. Alpha - trigger function is the same as pressing the alpha key on the keyboard. Laser - trigger function is the same as pressing the trigger on the laser. (default)
Reset Setups - resets Setup options to the default settings. You are prompted to Reset All Setups to Default? (No).
28
Page 29
M5000 Portable Data Terminal
American Microsystems, Ltd.
Non-Portable Mode Once the Non-port mode is selected from the Main Menu, the interface mode is automatically determined based on your cable connection. It may be necessary to reselect non-port mode on the Main Menu if cable changes are made during non-port mode. Two ways in which the M5000 PDT relays bar code data to the host computer are keyboard wedge and RS232 serial. Keyboard Wedge transmits bar code data to the host computer via a hardware device called the M5100 Keyboard Wedge. This device is connected in-line to the host computer’s keyboard and sends data to the host computer as if it were typed from the host keyboard. RS-232 Serial transmits bar code data to the host computer’s serial port. This mode uses the protocol and serial parameters from the Communications Setup option. (Refer to Comm. Setup page 21.)
Upgrade Flash, Previously, if you wanted to update portable bar code reader firmware, you would physically open the scanner and replace the EPROM and in some cases is costly, time consuming and complicated. Today you can use a much easier method. The flash memory can be easily updated using our communications interface cable, IBM compatible computer and a software file. You can download amended firmware only if American Microsystems Technical Support has instructed you to upgrade the firmware on your M5000 PDT.
Warning! When this option is selected the M5000 PDT warns you that you will lose all program files and data files if you proceed. You may wish to validate proper xmodem communication through your serial port. 1.
Connect the communications interface cable (RS-232) into an available RS-232 port on your computer.
2.
Connect the opposite end of the communications interface cable to the RJ45 10-pin connector on the bottom of the M5000 PDT.
3.
On your M5000 PDT from the Main Menu select Upgrade Flash (U). You will be prompted by the confirmation message, All Data & Programs Will Be Lost! Are You Sure? Choose Y or toggle this selection to (yes). The M5000 PDT is now waiting for connection.
4.
To access the M5000 Programmer software from WIN95 taskbar, click Start, select Programs, select M5000 Utilities and select M5000 Programmer.
5.
Under the Communications menu, select Upgrade Flash. The communications submenu is then brought up on the screen and file selection dialog box will prompt you to select a UPG file (image.upg).
6. 7.
Press ok to select UPG file. The Communications dialog will again appear press Send to upload flash upgrade. Once the file has been transmitted, the flash upgrade is complete. The M5000 PDT automatically returns you to the Main Menu. The options will be reset to factory defaults.
Browse - allows you to select the flash file you want to send. Send/Exit - after you select a file to send, press the Send button. While the M5000 Programmer is sending the file, the button changes to Cancel, allowing you to abort the transmission. 29
Page 30
American Microsystems, Ltd.
M5000 Portable Data Terminal
Using the M5005 Integrated Laser Scanner The M5500 PDT consists of the American Microsystems M5000 Portable Data Terminal integrated with our new M5005 Integrated Laser Scanner. These two units combine to form a powerful and easy-to-use data collection system. The M5500 provides all the features of the M5000 PDT together with the convenience of one-handed, portable scanning and the speed and accuracy of laser input. The M5500 PDT can be easily adapted for right- or left-hand use. The unit has two triggers that allow you to scan bar code data with your right or left hand. It can be positioned in your hand so that you can manually enter data and/or scan bar code labels as desired. (Refer to How to Scan & Enter Data on the M5500 PDT.) Included with the M5500 PDT is a communications program that makes uploading data from the RS-232 serial port directly into word processors, text editors, point-of-sale programs, inventory programs and other application programs quick and easy. Data can also be uploaded as an ASCII file. The M5500 PDT also comes with an easy-to-use Windows compatible program generator. The M5500 PDT programming software allows you to generate customer programs or use our program templates to configure a program to meet your specific needs.
How to Assemble the M5005 Laser Scanner Step 1:
Remove the two small Phillips-head screws that hold the black plastic retainer clip in place located on top of the M5000 PDT; then remove the retainer clip.
Step 2:
Attach the M5005 Laser Scanner base assembly to the top of the M5000 PDT by connecting the two 9-pin connectors. (The base assembly stays mounted to the M5000 PDT and provides easy removal when you want to change from right-hand operation to left.)
Step 3:
Select either left-hand or right-hand position, and secure the M5005 Laser Scanner by fastening it to the M5000 PDT with the two long Phillips-head screws provided.
Note: These two screws cannot be used later to secure the laser scanner in place.
30