For the AML M5000

Page 11

M5000 Portable Data Terminal

American Microsystems, Ltd.

How to Collect Your Data 1.

In the Main Menu, select Input, and select the program that you downloaded.

2.

Select *New File*, and input a filename. (You are now in data collection mode.)

3.

When finished with data collection, press exit; you are prompted with a confirmation message, Exit Data Entry, Are You Sure? (No). You can either press Y or toggle with the arrow key to select yes.

4.

Press Y or press enter at Save Data File (Yes)? This action returns you to the Select Program menu, press exit to access Main Menu.

How to Upload Your Collected Data We assume that the serial cable is connected to an available, functioning com port and all default communication parameters (xmodem, 9600, N, 8, 1) are used. If a timeout error occurs during this process, you will need to repeat all the steps to upload collected ASCII data. (Refer to Transmitting Files Using the M5000 PDT for details on ASCII files.) 1.

Using the M5000 Programmer software on your PC choose Communications, then Receive File.

2.

Enter a filename (.TXT) to receive and select Save. This action takes you to the Receive File dialog where you select Receive; Status Shows Waiting.

†Note: If Error Opening Com Port appears on the screen, click ok. Then select Communications, Setup and change the serial port to the available port you are using. (Default is Com1.) 3.

In the Main Menu on the M5000 PDT, choose Communications, and select Send, Data Files. Status shows: Sending (data file name) 100% complete Transmit complete Press any key The M5000 Programmer status box displays Completed when a file is successfully received.

†Note: You can view the file with a text editor or word processor. 4.

Once your file is successfully transmitted and a key is pressed you are prompted by a confirmation message, Erase Uploaded Data Files? (No), if desired, press Y or toggle the arrow key to select yes. When yes is chosen, the M5000 PDT verifies your selection and returns you to the Communication Select menu. Press exit to return to the Main Menu.

Connecting to Your Host Computer The M5000 Portable Data Terminal can be connected to your host computer with the M5100 Keyboard Wedge (optional accessory), RS-232 serial or a Hayes compatible modem. The M5100 Keyboard Wedge configuration integrates a specialized decoder between the host computer and the M5000 PDT allowing you to transmit data directly to your computer via the keyboard interface port. The RS-232 serial configuration utilizes communications software to a) transfer data directly into your application as keyboard data using Softcom, b) transfer data and programs back and forth between your host computer and the M5000 PDT using the M5000 Programmer software. The M5000 Portable Data Terminal supports xmodem protocol and can be connected to a Hayes compatible modem through the RS-232 serial port. 11

Page 12

American Microsystems, Ltd.

M5000 Portable Data Terminal

Using the M5100 Keyboard Wedge The M5100 Keyboard Wedge is an optional accessory of the M5000 Portable Data Terminal. It interfaces between a standard IBM compatible keyboard and your personal computer. The M5100 Keyboard Wedge transmits data to the computer as if it were typed from the keyboard. The advantage of using a keyboard wedge is that software is not needed for connectivity. The M5100 Keyboard Wedge interface connects between the keyboard and the PC with a Y-cable. The M5000 PDT connects to the wedge to upload data. The computer remains fully functional while data is transmitted via the keyboard directly into your computer’s application. In addition, the M5100 Keyboard Wedge has the ability to convert standard RS-232 data into keyboard data. M5100 Wedge Programmer Software is included with the purchase of the M5100 Keyboard Wedge. This application allows for modification of keyboard wedge settings such as transmit speed, keyboard type and RS-232 conversion settings. In most cases, the manufacturer default settings programmed into the M5100 Keyboard Wedge are acceptable and changes to the wedge programmer settings are not necessary. How to connect the M5100 Keyboard Wedge to your computer: 1. Turn off the power to your computer.

Warning! Failure to terminate the power can permanently damage the system. 2. 3. 4. 5. 6. 7.

Unplug the keyboard connector from the back of your computer and plug it into the female end of the Y-cable. Plug the male end of the Y-cable into your keyboard port. Connect the wedge to the 9-pin connector on the Y-cable. Connect the interface cable to the 9-pin male connector on the wedge. Connect the RJ45 10-pin connector end (resembles a telephone jack) of the interface cable to the bottom of the M5000 PDT. Turn on the power to your computer. In keyboard wedge mode, power to the M5000 PDT is automatically received from the PC.

Using the M5100 Wedge Programmer When the keyboard wedge cable is connected, the M5000 PDT switches to the keyboard wedge mode automatically. During keyboard wedge mode the M5000 PDT receives all its power from the keyboard port and does not use its internal battery. The M5000 PDT turns on and off with the host computer. The M5000 Utilities automatically includes the M5000 Programmer, M5100 Wedge Programmer, and Softcom. You may run these programs by selecting the appropriate icon. Follow these steps to initiate the M5100 Wedge Programmer software: 12

Page 13

M5000 Portable Data Terminal

American Microsystems, Ltd.

1.

To start the Wedge Programmer, choose Start, select Programs, select M5000 Utilities, select M5100 Wedge Programmer program icon.

2.

When you start the wedge programmer and have made necessary changes, choose OK to accept the settings.

Wedge Settings - define options such as interface mode, keyboard type, strip linefeeds, caps lock, num lock, auto caps, and alternate scan code however, default settings are acceptable and in most cases software changes are not necessary. Interface Mode - the M5100 Wedge Programmer settings include two modes for data transfer, the M5000 PDT mode (default) and the RS232 Serial mode. The M5000 PDT mode is the recommended method to transmit data while using the M5000 PDT. The RS-232 Serial mode is used when connecting an RS-232 device for the purpose of converting its output to keyboard data. Options for the RS-232 Serial must match the settings on your RS-232 device in order for data to transmit correctly.

Keyboard Type - option used to select keyboard type include: US standard (English) German French Italian Universal

Strip Linefeeds - option used to remove the line feed character from the data. Options include: None LF CR (line feed, carriage return) CR LF (carriage return, line feed) Always

Caps Lock - select either on or off to match the computer keyboard Auto Caps setting. If the Auto Caps option does not operate on your computer, use this function. Select on when the host computer’s keyboard Caps Lock setting is on. This setting transmits lower case alpha characters as shifted characters. Select off when the host computer’s keyboard Caps Lock is off. This setting transmits upper case alpha characters as shifted characters. Num Lock - select either on or off to match the computer keyboard Auto Caps setting. If the Auto Caps option does not operate on your computer, use this function. Select on when the host computer’s keyboard num lock setting is on. This setting transmits lower case alpha characters as shifted characters. Select off when the host computer’s keyboard num lock is off. This setting transmits upper case alpha characters as shifted characters. Auto Caps mode - the M5000 automatically transmits data in the correct upper and lower case, whether the host computer’s keyboard settings is on or off when Auto Caps is on.

13

Page 14

American Microsystems, Ltd.

M5000 Portable Data Terminal

Alternate Scan Code - this option is used only for computers that run Scan Code Set 3 (some Xwindows terminals and concurrent DOS).

Serial Port Settings - allows the Wedge Programmer to select the baud rate, parity and data bits and are applicable only in RS-232 serial mode.

Baud Rate - sets the transmission speed for the serial port on the wedge and must match the baud rate of the RS-232 device. Select one of the following: 300 2400 19200 600 4800 38400 1200 9600

Data Bits - sets the character length (number of data bits per character) for serial data and must match the data bits setting of the RS-232 device. Select either 7 or 8.

Parity - the parity setting must match the parity setting of the RS-232 device. Parity is used to provide a self-checking method for data transmission. Select one of the following: None Even Odd Mark Transmit Speed - this option incorporates a slide bar and sets the speed at which data will be transmitted to the computer. Older computer systems may require the transmission speed set to a slower rate. Diagnostics - option that executes a self-test program and performs the following tests on the M5000 PDT. Close the Diagnostics window when tests are completed. RAM Test ROM Checksum EEPROM Test Character Set LED Test RS-232 Serial Loopback Test (loopback connector required) RTS/CTS Loopback Test (loopback connector required) Status Log

How to Upload Collected Data Using the M5100 Keyboard Wedge We assume that you followed the previous steps in this section, connecting the M5100 Keyboard Wedge and the interface cable, you are now ready to upload the collected data. The cursor must be in the active application for you to upload your data. You can use Notepad for testing your M5000 PDT program settings. 1.

In the Main Menu of the M5000 PDT, choose Communications, select Send, Data Files.

2.

From your PC, select the M5000 Programmer, select Communications, Send and then select the collected data file. Your data then begins transmitting into your application and appears as keyboard data.

3.

Once your file is successfully transmitted and a key is pressed you are prompted with a confirmation message to Erase Uploaded Data Files? (No), if desired, press Y or toggle an arrow 14

Page 15

M5000 Portable Data Terminal

American Microsystems, Ltd.

key to select yes. When yes is chosen, the M5000 PDT verifies your selection and returns you to the Communications Select menu. 4.

Press exit to return to the Main Menu.

Using RS-232 Serial Configuration The M5000 PDT uses software developed by American Microsystems, Ltd. and runs on a Windows compatible computer. With the help of M5000 Programmer software, programs or data files can be transferred back and forth between the M5000 PDT and your host computer. Softcom can also be utilized when uploading data to emulate keyboard input. As pictured, the RS-232 serial interface is established by connecting the communications interface cable to an available RS-232 port on the host computer and attaching the RJ45 10-pin connector (resembles a telephone jack) to the bottom of the M5000 PDT. You must utilize the M5000 Programmer software to generate and transfer custom programs and configurations to the M5000 PDT for data collection in portable mode. To use the M5000 PDT in RS-232 serial nonportable mode select Non-port mode from the Main Menu (or press N). Use Softcom to enable RS-232 serial data to appear as keyboard data to the PC. Parameter settings such as baud rate, data bits, parity, etc. are preprogrammed at the manufacturing plant. These parameter settings can be changed through Comm. Setup (Communications Setup). How to connect the M5000 PDT to your computer: 1.

Connect the 9-pin end of the communications interface cable (RS-232) into an available RS-232 port on your computer.

2.

Connect the opposite end of the communications interface cable to the RJ45 10-pin connector on the bottom of the M5000 PDT.

Working with Softcom Software Softcom is a memory-resident PC program that allows data received from the serial port to appear as direct keyboard input and can be used with a bar code reader or serial output device. Softcom supports a wide range of serial port options and also supports flow control. Flow control regulates the incoming serial data and prevents the buffer from overflowing. Softcom runs in the background monitoring data from the serial port. When data is read from the serial port, the currently active application receives the data as keyboard input.

Installation & Setup for Windows 1. 2. 3. 15

Insert the Softcom diskette into your floppy drive. From the Windows taskbar, choose Run, type a:/setup. Installation dialogs guide you through the rest of the setup process.

Page 16

American Microsystems, Ltd.

M5000 Portable Data Terminal

Running Softcom 32: 1. 2.

To start Softcom, from the Windows taskbar, choose Start. Select Programs, choose Softcom 32 and select Softcom 32 program icon. The application runs from the Windows task tray.

If you need to change the communications options, right-click on the Softcom icon in the task tray and choose Configuration. Softcom has the option to automatically load when Windows starts. In addition, you can disable Softcom, exit the application or utilize the test utilities.

Softcom Communications Softcom options such as serial port, baud rate, parity, data bits, stop bits and xon/xoff flow control are defined by selecting Communications.

Serial Portdefines the PC serial communication port that Softcom uses. Select one of the following:

Com1 (default) Com2 Com3 Com4

Baud Ratesets the transmission speed for the serial port and must match the baud rate of the M5000 PDT. Select one of the following: 300 600 1200

2400 4800 9600 (default)

19200 38400 57600

Paritythe parity setting must match the parity setting of the M5000 PDT. Parity is used to provide a self-checking feature in your data transmission method. Select one of the following: None (default) Odd Even

Data Bitssets the character length (number of data bits per character) for serial data and must match the data bits settings of the M5000 PDT. Select either 7 or 8 (default).

Stop Bitsdefines the number of stop bits used during serial communication, choose 1 (default) or 2 stop bits.

Xon/Xoff Flow Controlenables xon/off software flow control during serial transmission. When receiving serial data, the M5000 PDT transmits a xoff character to stop incoming serial data and prevents the serial buffer from overflowing. When the M5000 PDT is ready to accept more data, a xon character is transmitted. On (default) Off

Keyboard Settingsallows function key and special key translation. 16

Page 17

M5000 Portable Data Terminal

American Microsystems, Ltd.

Function Keys - with Function Keys enabled, the M5000 PDT can accept ASCII characters and transmit a corresponding function key to the computer. The ASCII characters and values are listed in the table below: Function Key No Function Keys Use DC1-SUB (11H-1AH)

Use 81H - 8AH

Use Both

Description No function key translation. (default) ASCII characters 17-26 represent function keys F1F10. †Note: with this option on, it is not possible to represent the normal ASCII characters 17-26. Function keys F1-F10 are represented by extended ASCII characters 129-138. †Note: with this option on, it is not possible to represent the function keys in a bar code because all bar code symbologies support only the ASCII character set from 0127. Function keys F1-F10 are represented using both ranges DC1-SUB and 81H-8AH.

Special Keys - with Special Keys enabled, the M5000 PDT can accept a given non-ASCII character and transmit a corresponding special key to the computer. The ASCII characters and values are listed in the table below: Special Key No Special Keys Use 01H - 1FH

Use 8CH - 9BH

Use Both

Description No special key translation. (default) Special keys are represented within this range. †Note: with this option on, it is not possible to represent the normal ASCII characters 17-26. Special keys are represented within this range. †Note: with this option on, it is not possible to represent the special characters in a bar code because all bar code symbologies support only the ASCII character set from 0127. Special keys are represented using both ranges 01H - 1FH and 8CH - 9BH.

Daisy Chainingoption not applicable with the M5000 PDT.

17

Page 18

American Microsystems, Ltd.

M5000 Portable Data Terminal

How to Upload Collected Data Using Softcom While minimized, Softcom runs in the background monitoring data from the serial port. When data is read from the serial port, the currently active application will receive the data as keyboard input. Assuming that you followed the previous steps in this section, connecting the cable and enabling the Softcom software, you are now ready to upload the collected data. 1.

Use the M5000 PDT to select Comm. Setup and change Protocol to None; change Flow Ctrl to Xon/xoff. The remaining communications parameters must match Softcom settings.

†Note: Since Softcom emulates keyboard data, the cursor must be in the active application you wish to upload your data to. 2.

On your M5000 PDT select the Main Menu, choose Communications, then select Send, Data Files. Select the appropriate program and the collected data file, your data begins transmitting into your application and appears as keyboard data. Once your file is successfully transmitted and a key is pressed you are given a confirmation message to Erase Uploaded Data Files? (No), if desired, press Y or toggle the arrow key to select yes. When yes is chosen, the M5000 PDT verifies your selection and returns you to the Communications Select menu. Press exit to return to the Main Menu.

3. 4.

5.

Using a Modem The M5000 Portable Data Terminal supports xmodem protocol and can be connected to a Hayes compatible modem through the RS232 serial port as shown. (You need to purchase either a 9-pin or 25-pin modem cable to connect to your modem.) Collected data can be uploaded to a host computer over standard telephone lines. How to connect to your M5000 PDT: 1.

2.

Connect the modem cable to the RS-232 serial port on the modem. (9 to 25 pin adapter may also be required.) Connect the opposite end of the communications interface cable to the RJ45 10-pin connector on the bottom of the M5000 PDT.

Transmitting Files Using the M5000 PDT Data, program, setup, lookup, and clone files as well as status log and hex dump files can be transmitted to and from the M5000 PDT. This section outlines the M5000 PDT Send, Receive, and Communication Setup menus. Pressing any key during file transmission immediately aborts the transfer.

Communications Files are transmitted to your PC using the Communication Select menu and cannot be edited without the use of the M5000 Programmer. (Refer to the M5000 Programmer Help File for additional information.) The Communication Select menu is accessed through the Main Menu, where you select Communications and choose from the following submenus: Send, Receive, or Comm. Setup. 18

Page 19

M5000 Portable Data Terminal

American Microsystems, Ltd.

Send The Send option allows you to transmit data, program, setup, lookup, and clone files as well as status log and hex dump files from your PC. As the M5000 PDT transmits a file, the file status displays percent complete. When the file reaches 100% Complete, Transmit Complete is displayed. You are then prompted to press any key to return to the Communication Select menu.

Data Filesthis option allows you to send data files within a program via the keyboard wedge, RS-232 serial, or modem. You can send all data files or individual data files with transmission beginning immediately following the selection of either transmission mode (keyboard wedge, RS-232 serial or modem).

When All Data Files is selected, the M5000 PDT transmits every data file stored in your M5000 PDT. If you want to send data from a specific program, select the program, choose All Data Files for that program, or select a specific data file saved using that program. When either option is selected, the M5000 PDT prompts for one of the communication modes by default.

Programsthis option allows you to upload program files via RS-232 serial or modem. You can send all program files or individual programs with transmission beginning immediately following the selection of either transmission mode. Setupthis option enables all M5000 PDT setup menu selections to be uploaded via RS-232 serial or modem with transmission beginning immediately following the selection of either transmission mode. (RS-232 serial or modem) Lookup Filesthis option allows you to upload lookup files via RS-232 serial or modem. You can send all lookup files or individual lookup files with transmission beginning immediately following the selection of either transmission mode (RS-232 serial or modem). Clone Filesthis option enables you to send all M5000 system files including setup menu selections, programs, and lookup files (data files are not transmitted via this mode) stored in the source M5000 PDT to a target M5000 PDT or host computer. Transmission begins immediately following the selection of either transmission mode (RS-232 serial or modem).

Status Logsends the current status log file to the PC. Hex Dumpsends a hex file stored in the M5000 PDT for data recovery.

Receive The Receive option allows you to obtain data, program, setup, lookup and clone files, from your PC. You must select RS-232 Serial or Modem mode under Communications Mode. By default Waiting for Connect message appears. The M5000 PDT is now ready to automatically receive the correct file type from your PC. A Receive Complete message appears upon successful file transmission. Warning! When receiving a new clone file, the M5000 PDT erases all previous Setup Menu selections, programs, lookup files, and data files.

Comm. Setup (Communication Setup) All communication modes depend on components properly operating, including serial ports, cable assemblies and modems. Serial communication parameters must exactly match M5000 PDT settings and host communications software settings. This option allows you to specify the type of data the M5000 PDT sends and the mode that transmits the data. It also presets features such as dialing, phone number and serial communications parameters. 19

Page 20

American Microsystems, Ltd.

M5000 Portable Data Terminal

You can use one of two ways to access Communication Setup. From the Main Menu arrow down to Communications, then choose Comm. Setup. Another method you can use to access Communication Setup (Comm. Setup) from the Main Menu, is simply arrow down to Setup, and choose Comm. Setup.

Protocol - select one of the following options: None - protocol is not used. Xmodem - enables the xmodem protocol that is commonly used to ensure data integrity when communicating via telephone lines. The M5000 PDT automatically detects and supports xmodem CRC and xmodem checksum. Default is set the Xmodem.

Flow Control - is used when receiving serial data and prevents the serial buffer from overflowing. Select one of the following options: None - flow control is not used. Xon/xoff - enables Xon/xoff software flow control. When receiving serial data, the M5000 PDT transmits a xoff (Ctrl S) character to stop incoming serial data and prevents the serial buffer from overflowing. When the M5000 PDT is ready to accept more data, a xon (Ctrl Q) character is transmitted. RTS/CTS - enables RTS/CTS hardware flow control. When receiving serial data, the M5000 PDT drops the RTS line to stop incoming serial data and prevents the serial buffer from overflowing. When the M5000 PDT is ready to accept more data, the RTS is again inserted. Default is set to RTS/CTS.

Baud Rate - sets the data transmission speed for the serial port on the M5000 PDT and must match the baud rate of the host computer’s serial interface. Select one of the following options: 300 2400 19200 600 4800 38400 1200 9600 (default) 57600 Parity - the M5000 PDT parity setting must match the parity setting of the host computer’s serial interface and is used to provide a self-checking feature in your data transmission method. Select one of the following options: None (default) Odd Even

Data Bits - sets the character length (number of data bits per character) for the serial data and must match the data bits setting of the host computer’s serial interface. Select either 7 or 8 (default).

Stop Bits - defines the number of stop bits used during serial communication, choose 1 (default) or 2 stop bits.

Char Delay (Character Delay) - specifies the amount of delay inserted between each transmitted character. This option slows the transmission rate to compensate for slow host computers that require time to process each character. Programmable range is 0ms to 99ms. (Default is one.) 20