Page 1

M5000 Portable Data Terminal

American Microsystems, Ltd.

Introducing the M5000 PDT American Microsystems, Ltd. first introduced the M3000 Portable Bar Code Reader in 1991. The overwhelming success of the M3000 was due in part to the versatility, and durability of the unit. Now, American Microsystems introduces the ultra-versatile, high performance, designed-to-fit-yourbudget, M5000 Portable Data Terminal (PDT). American Microsystems came up with the clever idea to combine the reliability and durability of the M3000 with the convenience and accuracy of a data terminal. This unit not only has limitless uses, but also has a rugged, simple ergonomic design that easily fits one-hand and a small budget. The ergonomic design is built smart: rugged, lightweight, compact, easy-to-use, easy to upgrade and has the advantage of two superior integrated units. Our specially designed software guides the user through the data collection process with a four by twenty character line LCD display. Our competitive advantage is that the M5000 PDT is user friendly especially for non-computer users and it’s easily flash upgradeable.

What to Expect This user’s guide provides you with an overall physical description, keypad values, technical specifications and performance capabilities of the Model 5000 Portable Data Terminal. In addition you will learn how to: 9 Connect to your host computer 9 Customize your M5000 PDT 9 Connect your input device 9 Install the M5000 Programmer Software 9 Run Softcom software 9 Create and send programs 9 Use and load built-in programs 9 Collect and upload data 9 Send and receive data 9 Connect and use the M5100 Keyboard Wedge 9 Connect and use the RS232 Serial interface 9 Download amended or updated firmware

Warranty We guarantee that you will be one-hundred percent satisfied with products purchased from American Microsystems, Ltd., however, you can return the M5000 Portable Data Terminal within thirty days from the invoice date for a full refund (excluding shipping charges). A two-year warranty against material defects and workmanship from the date of shipment is guaranteed by American Microsystems, Ltd. Products are sold on the basis of specifications applicable at the time of manufacture. AML shall have no obligation to modify or update products once sold. At our option, we will repair or replace, at no charge, any unit that proves to be defective providing the appropriate steps are taken to procure an RMA number and shipping instructions from American Microsystems, Ltd.

1

Page 2

American Microsystems, Ltd.

M5000 Portable Data Terminal

When You Need Support American Microsystems, Ltd. provides telephone support for all Model 5000 Portable Data Terminal users. If you have questions or a problem you are unable to resolve after consulting the operation manual, the Help feature, or our web address, http://www.barcodepower.com, you can telephone (800) 648-4452 during business hours Monday through Thursday (excluding holidays) 8:00 a.m. to 5:30 p.m. CST and Friday 8:00 a.m. to 5:00 p.m. In addition, you can refer to our website to download software updates, program updates, and documentation, check for new releases, firmware revisions and product updates. You can call for a Return Merchandise Authorization number (RMA) to return the product for refund or repair. Before contacting Technical Support, please be prepared to furnish the following information: 9

9 9 9 9

Your company information: company address, ship-to address, telephone number, and AML customer number Product model number Product serial number Date of purchase Copy of invoice

When returning the product for a refund, it must be returned prepaid in “like new” condition including all documentation and packaging (original and unmarked) together with a copy of the invoice. To expedite the repair process, include information as to the nature of the problem.

Physical Description The M5000 PDT features a four-line by twenty character LCD (5 X 7 dot matrix) display and a thirtynine-key keypad. It is fitted with a customized keypad and built-in configuration memory for optimum use. Parts of the M5000 PDT include: 9 9 9 9 9 9 9

LCD Display Keypad Serial Port RJ45 10-pin Connector Hand Strap Battery Compartment Scanner Triggers (right and lefthand accessibility)

2

Page 3

M5000 Portable Data Terminal

American Microsystems, Ltd.

Getting to Know the Keypad The M5000 Portable Data Terminal is equipped with thirty-nine keys that are divided into blue, grey, red and white keys. When pressed, each key emits an audible beep that can be disabled if desired. Refer to Keypad Beep for instructions on how to disable the key beep. The six blue keys consist of Func, four arrow keys and the Alpha key. The Func key activates the Select Function menu during data collection mode. Hot keys select specific menu items without scrolling the entire menu. For example, press F in order to Find Text. The alpha key toggles between alpha and normal mode and is used to switch between upper and lower keys. When in alpha mode, press a key to insert the letter that appears on or above the upper part of the key. A flashing solid block will let you know when you are in alpha mode. Eighteen grey keys represent letters, special characters, spaces and calculator keys. Six keys can be used to function as a calculator (+ - * / = %). Each key also serves a dual function and can be used either in normal or alpha mode except the INS, DEL, EXIT and SPACE keys. Red keys are the PWR key and the Enter key. The PWR key is used to power the M5000 PDT on and off except in M5100 Keyboard Wedge mode. When the M5000 PDT is powered off or laps into the time-out mode, you will return to the same display at which you were powered off, after you power on again. The Enter key selects menu items as well as accepts information for an input file. The remaining thirteen white keys are numeric keys. When in alpha mode, the keys produce the designated letter with the exception of the plus key. All other numbers, plus sign, minus sign and decimal are inserted when you toggle to normal mode. A flashing cursor lets you know that you are in normal mode. For specific key values, see the chart on the following page.

3

Page 4

American Microsystems, Ltd.

M5000 Portable Data Terminal

Key Values Blue Keys Func

Key Value Activates the Select Function menu that only operates during data collection mode (Input). Refer to Select Function Menu for key descriptions.

Func + Hot Key

Selects specific menu items without scrolling through the entire menu

Alpha

Toggles between alpha & normal modes; inserts the character printed on or above the actual key

5Up arrow

Moves the display screen up one line at a time or moves the display screen up one menu level

3Left arrow

Moves the cursor left one character at a time and toggles between menu selection options

6Down arrow

Moves the display screen down one line at a time or moves the display screen down one menu level

4Right arrow

Moves the cursor right one character at a time and toggles between menu selection options

Grey Keys Alpha INS

A-Z Special Keys: ? # $ + - * / = % : ; space @_ Inserts data at the cursor position and moves all existing data to the right

DEL

Deletes characters at the cursor position or if cursor follows a string of characters, it deletes the characters to the left of the cursor

EXIT

Exits operation being performed

SPACE

Enters the space character

Red Keys PWR Enter White Keys Numeric

Powers unit off/on Accepts information in an input file & advances the cursor to the next input field; also selects menu items 0-9, + - . When 7 through period (.) are in alpha mode, letters O-Z are produced.

Display Screen The display screen is a liquid crystal display (LCD) and exhibits up to four lines of text with a maximum of twenty characters per line. An obvious advantage to this type of display screen is that you are able to view four lines of twenty characters per line of data at a time.

Beep When pressed, each key emits an audible beep that can be disabled if desired. Choose Setup from the Main Menu, arrow down and choose Other Setup, arrow down to select Keypad Beep; use either left or right arrow key to toggle the off/on option.

4

Page 5

M5000 Portable Data Terminal

American Microsystems, Ltd.

The M5000 PDT also provides an audible beep when a bar code has been successfully scanned. To change the tone and length of the beep, choose Setup, Bar Codes, Bar Code Beeper and toggle between desired beeper options. Other beep sequences are programmed to let you know about possible problems. For a full range of system errors, please refer to System Warnings.

Batteries Three AA alkaline batteries are used to power the M5000 PDT and serve as a power source for input devices attached to the unit. When the battery power drops below an adequate level, the unit indicates Battery Low on the display screen. To replace the batteries, follow the steps below: 1.

Turn off the power to the M5000 PDT.

2.

Place the unit face down and unlatch the bottom strap from the unit.

3.

Press down slightly on the battery compartment and slide the cover to the right, away from the case.

4.

Carefully lift the batteries from the case.

5.

Replace the batteries with three new AA batteries in the positions indicated by the diagram inside the compartment.

6.

Replace the battery cover by sliding it to the left until it snaps into place.

7.

Replace the hand strap latch into its fastener.

The internal lithium battery provides backup power that supports the RAM memory when the main batteries are removed. Collected data as well as system defaults including the internal clock are protected by backup battery power.

Taking Care of your M5000 PDT Protect your M5000 Portable Data Terminal from damage by following the simple recommendations below. Electrical components can be damaged by exposure to intense electrical fields, therefore avoid exposing the M5000 PDT to the following conditions: 9 Avoid electrostatic discharge produced by friction such as heavily carpeted areas during periods of low humidity. 9 Avoid using the unit with a modem during electrical storms. 9 Avoid exposure to sources of intense arcing 9 Avoid exposure to powerful electromagnetic fields such as large motors, induction coils, transformers, etc. 9 Avoid exposure to sources of ionizing radiation such as x-rays, etc. Mechanical components can be damaged by exposure to the following conditions:

5

9

Direct exposure to water - do not immerse

9

Physical contact or hard impact

9

Extreme heat or open flame; do not leave on a vehicle dashboard or enclosed vehicle

9

Highly corrosive environments

9

Strong industrial cleaning solvents

Page 6

American Microsystems, Ltd.

M5000 Portable Data Terminal

Technical Specifications Type Dimensions Input Devices Accessories

Keypad Special Keys Display Memory

Symbology Decodes

Serial

Microprocessor Interface Power Durability Environmental

Warranty

Description Height: 7 .75” Width: 3.75” Depth: 1.625” Weight: 13 oz. Wand, Laser, CCD & Slot Reader (undecoded) M5100 Keyboard Wedge, Memory Module, M5005 Integrated Laser Scanner (Contact your AML Sales Rep for more details.) Case, Belt and Shoulder Strap 39-key keypad with alphanumeric & special character keys Alphanumeric, function, insert, delete, exit, power, space, arrow keys 4-line X 20 character LCD display 256K bytes standard RAM memory with expandable Memory Module available (contact your AML Sales Rep for more details); 2 MB flash EPROM Code 39, UPC-A, UPC-E, EAN-13, EAN-8, UPC/EAN Addons, Interleaved 2 of 5, Codabar , Code 128, Code 93, MSI/Plessey, Code 11 Baud rates: 300-57600 Data bits: 7, 8 Stop bits: 1, 2 Parity: none, odd, even Intercharacter delay: 0-99ms 16.67 MHz RS-232 Serial, optional M5100 Keyboard Wedge or modem Operating: 3 AA batteries Backup: Lithium Shock resistant with drops up to 6’ Operating temperature: 0° centigrade to +50° centigrade (+32° Fahrenheit to +120° Fahrenheit) Relative humidity: 5% to 95% (non-condensing) Two-year warranty, thirty-day money back guarantee

6

Page 7

M5000 Portable Data Terminal

American Microsystems, Ltd.

Main Menu When you first power on the M5000 PDT, the Main Menu prompts you to select from the following options. Function Input Communications

Hot Key I C

Setup

S

Status

?

Calculator

A

Erase Copy program

E P

Non-port mode

N

Time

T

LCD Contrast Upgrade Flash

L U

Description Initiates data collection. Allows transfer of files between the M5000 PDT & the PC. Configures all system-wide parameters: Date/Time, Bar Codes, Comm. Setup, Laser/CCD options, Other Setup, and Reset Setups. Displays the following information: 9 ROM version 9 ROM Checksum 9 Flash Version 9 Total Memory 9 Number of bytes available 9 Percentage of memory available 9 Total number of Programs stored 9 Total number of Lookup files stored 9 Total number of Data files stored 9 AA Battery status 9 Lithium battery status 9 Recall Data Provides access to a 4-function calculator. (Alpha mode is not active during calculator mode.) Erases stored data, lookup and program files. Loads a built-in program into RAM that enables you to collect data. Places M5000 PDT in either M5100 Keyboard Wedge mode or RS-232 non-portable mode. Displays setting for the year, month, day, hour, minute, second, a.m. or p.m. Adjusts display contrast with left and right arrows. Updates the M5000 PDT using the communications interface cable, PC, and M5000 Programmer software.

†Note: Five minutes after the last activity is performed on the M5000 PDT, it automatically powers off. This timeout can be adjusted from one to sixty minutes (refer to Setup, Other Setup, Timeout). When you power on the M5000 PDT again, the last menu that you accessed is then displayed.

7

Page 8

American Microsystems, Ltd.

M5000 Portable Data Terminal

Select Function Menu During data collection mode (Input), you can press the Func key, and the Select Function menu prompts you to choose one of the following functions: Function Find

Hot Key F

Goto Record Status

G ?

Insert Record

I

Clear Calculator Erase Recall

C A E R

Store

S

First Record Last Record Prev. Record Next Record View Lookup Time

M N J K V T

LCD Contrast

L

Description Allows you to search during input mode for a string of characters that match the find text. Up arrow searches for a match previous to the current field. Down arrow searches for a match following the current field. Enter searches for the first match from the beginning of the file. (Search method used for scanning within this field.) Moves to a specified record Displays the following information: 9 ROM version, ROM Checksum, Flash version 9 Total memory, number of bytes available, percentage of memory available 9 Current record, current program stored, current file stored 9 Number of program files stored, number of lookup files stored, total number of data files stored 9 AA Battery status, Lithium battery status 9 Recall data Inserts records into Input and Program modes. While collecting data, press Func, then press I (Insert) to insert an empty data record before the one being viewed. Clears an entire input field Provides access to a 4-function calculator Erases a record or an entire data file Inserts data that has been stored with the Store function. Press Func, then R (Recall); the information is inserted in place of existing data in the current input field. Stores the current input field to be used with the Recall function. Press Func, then press S (Store); the information is stored in memory and can be recalled using Func R (Function Recall). Moves to the first record of the current program Moves to the last record of the current program Moves to the previous record of the current program Moves to the record after the current record Displays selected lookup file Displays setting for the year, month, day, hour, minute, second, a.m. or p.m. Adjusts display contrast with left and right arrows

8

Page 9

M5000 Portable Data Terminal

American Microsystems, Ltd.

Quickly Getting Started This section takes you through the basics of installing the M5000 Programmer in Windows and connecting your input device to the M5000 PDT. It also shows you how to use built-in programs, create your own program, how to load a program, as well as how to collect and upload data to your computer. You can refer to the Help feature in the M5000 Programmer for further details on all dialog prompts used in the examples presented.

Connecting Your Input Device The M5000 PDT can be coupled with a variety of input devices such as wands, lasers, slot readers and CCDs (undecoded).

†Note: Be sure your M5000 PDT is not on during the connection process. How to connect to your M5000 PDT: 1. As shown, plug the 9-pin connector located on the bottom of the input device (laser), into the 9-pin receptacle located on the top of the M5000 PDT. 2. Turn on the power to your M5000 PDT. (In M5100 Keyboard Wedge mode, power is automatically received from the PC.)

M5000 Programmer Installation & Setup To install the M5000 Programmer and related utilities, insert the CD-ROM into the drive, and follow the instructions presented by the installation wizard (you may need to manually start the Setup.exe application if the installation wizard does not start automatically). To uninstall the M5000 Programmer or related utilities, click on Start, Control Panel and use the Add/Remove Programs utility to remove the options you wish to uninstall. The M5000 Programmer and M5000 PDT work with a number of types of files, each of which has a different purpose. Program File─a M5000 program is a collection of identifiers that indicate to the user a request for data. Project File─a M5000 project is a single program and any associated lookup file and data file. This allows you to quickly and efficiently manage any files that your program is using. Lookup File─a lookup file allows you to specify an input field used for data verification. Lookup file data restricts the contents of specified input during data input. Unless allowed by a lookup option during input, the program accepts data listed only in the lookup data file. Configuration File─a configuration file contains all of the possible configuration properties and attributes that are available on the M5000 PDT. Library File─a library file is used to completely configure the M5000 PDT. Data File─a data file is created as the result of entering data into a program's prompts. However, it can also supply pre-existing data to a program's prompts as they are displayed on the M5000 PDT.

9

Page 10

American Microsystems, Ltd.

M5000 Portable Data Terminal

Using Built-In Programs Six programs are pre-programmed into the M5000 PDT for data collection. To use these programs, select Copy Program. The prompts for each program (P1 through P6) are as they appear in the display below. Comma delimited programs (P2C through P5C) are also included. P1 ITEM NUMBER

P2

P3

P/N

P/N

QTY

QTY

P4

P5

P/N LOC

QTY

P6

P/N UOM

QTY DESCRIPTION

Rec 1 of 1

Rec 1 of 1

Rec 1 of 1

Rec 1 of 1

Rec 1 of 1

Rec 1 of 1

How to Load Sample P2 Program on the M5000 PDT 1.

In the Main Menu, select Copy Program.

2.

Arrow down and select sample P2 program. The prompt reads Copying P2 to RAM, then P2 Copied to RAM, press any key.

3.

After you press any key, the Main Menu appears. The P2 program is loaded and ready to collect data.

How to Collect Data on the M5000 PDT Using Sample P2 Program 1.

In the Main Menu, select Input. Choose P2 from the Select Program list.

2.

Select *New File* and input a filename. (You are now prompted to enter data: (P/N, QTY and Rec 1 of 1.)

3.

When you finish entering data, press exit. The M5000 PDT prompts you with a confirmation message to Exit Data Entry Are You Sure? (No), to exit press Y or toggle the arrow key to select yes.

4.

Press Y to Save Data File? or toggle the arrow key to select yes. The M5000 PDT returns you to the Select Program menu where you can choose another program or exit and return to the Main Menu.

How to Send a Program to the M5000 PDT We assume that the serial cable is connected to an available com port and all default communication parameters (xmodem, 9600, N, 8, 1) are used. The following steps can be used to send a program to the M5000 PDT. 1.

Using the M5000 PDT select Communications, choose Receive.

2.

Select RS-232 Serial under Communications Mode, (prompt shows Waiting for Connect).

3.

On your PC, select Send icon or you can go into the Communications Menu and choose Send File.

4.

Select a program file to send, choose ok, and select Send.

†Note: If an error occurs, select Setup to choose an available com port or repeat steps 2 and 3. The M5000 PDT displays Receive Complete when the file is received. 5.

Press exit to return to the M5000 PDT Main Menu.

Warning! When duplicate filenames are used during data file transmission, the new file automatically overrides the existing file. All previous data will be lost. 10