Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 4

M5000 Portable Data Terminal, pages 31 to 38

Pages 31 to 38 of 38

The original document is the PDF (789 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the AML M5000

Page 31

M5000 Portable Data Terminal

American Microsystems, Ltd.

How to Rotate the M5005 Laser Scanner Step 1:

Remove the two small Phillips-head screws that hold the laser scanner in place. Lift straight up to separate the laser scanner from the base assembly.

Step 2:

Rotate the M5005 Laser Scanner 180 degrees so it faces the desired scanning direction.

Step 3:

Attach the M5005 Laser Scanner onto the base assembly and secure it in place with the two Phillips-head screws.

How to Scan & Enter Data on the M5500 PDT Step 1:

Hold the M5500 PDT in either your left or right hand and aim the laser approximately 3 to 6 inches from the bar code label. Note: Typical scanning distance varies from 3 to 22 inches. The maximum scanning distance depends on the density of your bar code.

Step 2:

31

The M5500 PDT should be comfortably positioned in your hand for you to enter data and scan bar code labels as shown.

Page 32

American Microsystems, Ltd.

M5000 Portable Data Terminal

Specifications The M5005 Integrated Laser Scanner uses a low-power visible laser diode. Although momentary exposure to a CDRH Class II laser is not known to be harmful, avoid staring directly into the light beam, extended exposure may cause damage to your eyes. Light Source Laser Output Power Scan Rate Laser Class

630-680 nm laser diode 1.0 mW maximum 35 + 5 scans per second CDRH Class II

Caution: Changes or modifications not expressly approved by American Microsystems, Ltd. could void the user's authority to operate this equipment.

FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous visible laser light exposure. The following Certification/Identification labels are attached to the M5005 Integrated Laser Scanner in compliance with FCC Rules.

32

Page 33

M5000 Portable Data Terminal

American Microsystems, Ltd.

System Warnings Warning Message Input Has Data Cannot Overwrite Input Is Full Cannot Insert Char Input Not Found In Lookup Table Input Not Found Accept Anyway (Yes) No Editing Allowed Bar Code Is Too Long/Short For Input Input Is Already On File No Programs Exist Out Of Memory No Data Files Found Duplicate Filename Complete Record Before Searching Complete Record Before Inserting *END OF FILE* No More Inputs Cannot Insert Before a Header Input Not Satisfied Program Already Loaded in RAM Invalid Record Number Lookup File Is Not In Memory Almost Out Of Memory New Record Has Been Inserted

33

Warning Description Reading a bar code into a data input field and the Bar Code Overwrite option is off. During data input, maximum input size specification has been reached and will not allow additional characters to be inserted. Data entered in a lookup field does not match and a custom error message is not defined. Data entered in a lookup field does not match and the option, Accept Mismatches is on. User cannot edit a No Edit field. A bar code read into the current input field is too long/short and not allowed by min/max specifications. A duplicate input has been detected when the option NO Duplicates Allowed is enabled. No programs have been created; either a built-in or custom program must be loaded. Accessing Input mode with less than 256 bytes of free memory or receiving a file that exceeds available memory. Accessing Input mode and selecting a program with the option Receive Data Files only and that program has no data files. User tries to enter a data file name and that name is already used by another data file. User tries to search from within data input before the current record is satisfied. User tries to insert a record from within data input before the current record is satisfied. End of defined program inputs has been reached. User tries to insert a record during data input while accessing a header record. User tries to advance to a new record before the current record is satisfied. User tries to load a built-in copy of program P1-P6 and it is already loaded in RAM. Using the Goto Record option, user tries to enter an invalid record number. The lookup file specified in the program has not been loaded into memory. User tries to access data input with less than 1K of memory remaining. User inserts a new record during data input.

Page 34

American Microsystems, Ltd.

Warning Message Invalid Bar Code Type No Data Files Found Transmit/Receive Aborted By User Receive Error Checksum Error No Carrier Invalid ASCII File Invalid System File Invalid Data File File Name Error Invalid Data File Prog Name Error Program Not Defined Invalid Data File File ID Error Timeout Error Transmit Error No Lookup Files Found INVALID PASSWORD Press Any Key No Match Found No Programs Exist All Programs Have Data Files Recall Buffer is Empty Recall Data is Too Short/Long for Input Recall Data Not Valid For Input Invalid Bar Code Data For Input A Power Fail Has Occurred Battery Low Change Battery Soon

M5000 Portable Data Terminal

Warning Description Bar code type does not match current input field specifications. When attempting to upload data, no data files are found. User presses a key causing an abort. Indicates the received communication aborted with an error. An invalid checksum is detected in a system file. Communications carrier was lost during modem transfer. ASCII file is too long/short or invalid to receive. System file is too long/short or invalid to receive. Data file name was either blank or more than 8 characters. Program file name was either blank or more than 8 characters. Program specified in the data file is not found or programs do not exist to SEND. Invalid file ID for ASCII file. †Note: ID must be (D) data or (L) lookup. No response from sender/receiver; timeout occurs. Indicates the transmitted communication aborted with an error. User tries to Send or Erase lookup files when there are none in memory. User tries using an invalid password when trying to access Setup with the Password option on. After conducting a Find, no matches are found. User tries to erase a program where none exist. User tries to erase programs and all programs have data files included. Data files must be erased first. Using the Recall option before data input has been stored. Data recalled into the current input field is too long/short and not allowed by min/max specifications. Recall data does not match the current data input specifications. Bar code data does not match the current data input specifications. Power to the M5000 PDT has failed or a checksum failure caused the M5000 PDT to abort. Low battery detected; replace with AAA batteries.

34

Page 35

M5000 Portable Data Terminal

American Microsystems, Ltd.

Troubleshooting Guide Problem When the power button is pressed, the M5000 PDT does not turn on. Keyboard locks-up Bar codes will not scan. Losing data during serial communications Difficulty scanning bar codes while using laser or CCD

The M5000 PDT turns off automatically

When entering data to assign the file or program a name, I cannot enter special characters. The M5000 PDT beeps if I try to enter more than 8 characters for a filename. Why does the cursor blink with a solid block and sometimes with an underline? I keep getting a Keyboard Wedge Error. When I upgraded the flash memory, all my data was lost. A modem adapter is connected between the communications interface cable and the modem and I still cannot use my modem. When I received a new clone file, all my previous setup menu selections disappeared.

35

Solution Check the batteries; make sure they are installed in the correct position. Check all cable connections, if applicable. Check Wedge Programmer settings. Check the bar code setup to verify the bar code to be scanned is enabled in the M5000 PDT or your program. Baud rate could be set too fast; adjust to a slower rate or check protocol for correct setting. Laser or CCD could be too close or too far away from the bar code or the scanning angle is incorrect. Scan within the guidelines specified for your type of scanner. To conserve battery power, the M5000 PDT has a timeout feature with default 5-minutes. Power the M5000 PDT on and it resumes in the same menu you were in before it timed-out. The file name and the program name are programmed to accept only alphanumeric characters and not special characters such as: , ?, #, etc. When entering a file name, only eight characters are accepted. When the cursor blinks with a solid block, alpha mode is in use; when the cursor blinks with an underline, standard mode is in use. Keyboard Wedge is not connected correctly - check your connections. When this option is selected, the M5000 PDT warns you that you will lose all program and data files if you proceed. A 9 to 25 pin adapter may also be required to complete the connection.

The M5000 PDT erases all previous setup menu selections, programs, lookup files and data files.

Page 36

American Microsystems, Ltd.

M5000 Portable Data Terminal

Non-ASCII Special Characters Hex Code

ASCII

/8C /8D /8E /8F /90 /91 alt on alt off ctrl on ctrl off shift on shift off

†Note: Keys must be used in pairs, for example, a desired ALT must be transmitted as ALT ON, A, ALT OFF.

Hex Code

Function Key

Hex Code

Function Key

/92 /93 /94 /95 /96 /97 /98 /99 /9A /9B page up page down home end delete insert left arrow right arrow up arrow down arrow

/F1 /F2 /F3 /F4 /F5 /F6 /F7 /F8 /F9 /F0

1 2 3 4 5 6 7 8 9 10

Non-ASCII Delay Character Values Hex Code

Delay (sec)

/D1 /D2 /D3 /D4 /D5 /D6 /D7 /D8 /D9

1 2 3 4 5 6 7 8 9

†Note: The characters above are valid for use in SOF text, EOF text, SOT text, EOT text, preamble (prefix) and postamble (suffix) fields.

36

Page 37

M5000 Portable Data Terminal

American Microsystems, Ltd.

Special and Function Keys for Bar Codes The following characters are transmitted during non-portable (keyboard and RS-232) mode with Special Keys and Function Keys enabled.

DEC 1 2 3 4 5 6 7 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31

37

HEX CODE /01 /02 /03 /04 /05 /06 /07 /0B /0C /0E /OF /10 /11 /12 /13 /14 /15 /16 /17 /18 /19 /1A /1C /1D /1E /1F

ASCII SOH STX ETX EOT ENQ ACK BEL VT FF SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB FS GS RS US

OUTPUT CHARACTER LEFT ARROW RIGHT ARROW UP ARROW DOWN ARROW HOME END DEL PAGE UP PAGE DOWN SHIFT ON SHIFT OFF INS F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 CTRL ON CTRL OFF ALT ON ALT OFF

SPECIAL KEYS ENABLED X X X X X X X X X X X X

FUNCTION KEYS ENABLED

X X X X X X X X X X X X X X

Page 38

American Microsystems, Ltd.

M5000 Portable Data Terminal

ASCII Character Chart DEC 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

HEX CODE /00 /01 /02 /03 /04 /05 /06 /07 /08 /09 /0A /0B /0C /0D /0E /0F /10 /11 /12 /13 /14 /15 /16 /17 /18 /19 /1A /1B /1C /1D /1E /1F /20 /21 /22 /23 /24 /25 /26 /27 /28 /29 /2A /2B /2C /2D /2E /2F /30

ASCII NUL (CTRL 2) SOH (CTRL A) STX (CTRL B) ETX (CTRL C) EOT (CTRL D) ENQ (CTRL E) ACK (CTRL F) BEL (CTRL G) BS (CTRL H) HT (CTRL I) LF (CTRL J) VT (CTRL K) FF (CTRL L) CR (CTRL M) SO (CTRL N SI (CTRL O) DLE (CTRL P) DC1 (CTRL Q) DC2 (CTRL R) DC3 (CTRL S) DC4 (CTRL T) NAK (CTRL U) SYN (CTRL V) ETB (CTRL W) CAN (CTRL X) EM (CTRL Y) SUB (CTRL Z) ESC (CTRL [) FS (CTRL \) GS (CTRL ]) RS (CTRL 6) US (CTRL -) SP ! " # $ % & ' ( ) * + , . / 0

DEC 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97

HEX CODE /31 /32 /33 /34 /35 /36 /37 /38 /39 /3A /3B /3C /3D /3E /3F /40 /41 /42 /43 /44 /45 /46 /47 /48 /49 /4A /4B /4C /4D /4E /4F /50 /51 /52 /53 /54 /55 /56 /57 /58 /59 /5A /5B /5C /5D /5E /5F /60 /61

ASCII 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ ` a

DEC 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

HEX CODE /62 /63 /64 /65 /66 /67 /68 /69 /6A /6B /6C /6D /6E /6F /70 /71 /72 /73 /74 /75 /76 /77 /78 /79 /7A /7B /7C /7D /7E /7F

ASCII b c d e f g h i j k l m n o p q r s t u v w x y z { ¦ } ~ DEL

38