Page 79
6Setup Procedures
Protocol NONE*
No PROTOCOL is used. The serial buffer can contain a maximum of 128 characters.
XON/XOFF
Enables XON/XOFF PROTOCOL. When receiving, the M3000 transmits an XOFF (control S) character to stop incoming serial data. This prevents the serial buffer from overflowing. Once the reader is ready to accept more data, an XON (control Q) character is transmitted to enable reception of more serial data. The XOFF will be transmitted when the buffer fills to 128 characters. When transmitting, the M3000 sends data until an XOFF (Control S) character is received. It will not resume data transmission until an XON (Control Q) character is received.
Output The Output setting sets the data format for one of the following modes: ASCII*
The mode used with standard ASCII terminals.
PCSCAN This mode is commonly used with "PC Terminals" that transmit PC SCAN Codes to the computer, rather than standard ASCII Codes. Two operating systems that use PC SCAN Codes are: PC-MOS, and CONCURRENT DOS.
Baud Rate The baud rate sets the data transmission speed for the serial port on the M3000. The M3000's baud rate must match the baud rate of the attached computer's serial interface. Select one of the following: 300 1200 4800 19200
600 2400 9600* 38400
Data Bits Sets the character length (number of data bits per character) for the serial data. The M3000's Data Bits setting must match the data bits setting of the attached computer's serial interface. Select one of the following: 7 8*
Parity The M3000's Parity setting must match the parity setting of the attached computer's serial interface. Select one of the following: NONE* EVEN ODD MARK
Stop Bits Sets the number of Stop Bit characters for the serial data. Select one of the following: 1* 2
6-11
Page 80
M3000 Bar Code Reader User's Guide
Character Delay Character Delay (Char Delay) specifies the amount of delay that is inserted between each transmitted character. This option slows the transmission rate to compensate for slow host computers that require time to process each character. Default setting = 1 millisecond Programmable range: 0ms - 99 ms
Duplex The Duplex setting determines whether data is sent from the M3000 to the Host only or to both the Host and Terminal. The M3000's Duplex setting must match the duplex setting of the Terminal's serial interface. FULL* In the Full Duplex mode data is sent only to the Host. The host computer receives the data and echoes it back to the terminal. HALF
In the Half Duplex mode data is sent to both the Host and Terminal at the same time.
Caps Lock Use this option to match the terminal keyboard's CAPS LOCK status. ON *
Select ON when the terminal keyboard's CAPS LOCK is turned ON. This setting transmits lower case Alpha characters as Shifted characters.
OFF
Select OFF when the terminal keyboard's CAPS LOCK is turned OFF. This setting transmits upper case Alpha characters as Shifted characters.
Num Lock Use this option to match the terminal keyboard's NUM LOCK status. ON
Select ON when the terminal keyboard's NUM LOCK is turned ON.
OFF *
Select OFF when the terminal keyboard's NUM LOCK is turned OFF.
Serial Beep ON*
Enables the 'Beep' tone. M3000 beeps after receipt of serial data string.
OFF
Disables the 'Serial Beep' tone.
Auto Advance
6-12
ON
Automatically advances to the next input after receipt of a serial data string.
OFF*
Does not automatically advance after receipt of a serial data string.
Page 81
6Setup Procedures
Bar Codes CODE 39 Decoder ON*
Enable reading CODE 39 labels.
OFF
Disable reading CODE 39 labels.
Full ASCII ON
Enable the Full ASCII extension to CODE 39. Decoder must be set ON.
OFF*
Disable the Full ASCII extension to CODE 39. This sets the reader to the standard CODE 39 mode.
Check Digit ON
Enable the Mod 43 Check Digit for CODE 39. When this option is enabled, only CODE 39 labels that contain a valid check digit will be read.
OFF*
Disable the Mod 43 Check Digit. Check digit verification is not performed.
Send Check Digit ON
Transmit the Mod 43 Check Digit with the bar code data. Mod 43 Check Digit must be set ON.
OFF*
Do not transmit the Mod 43 Check Digit.
Concatenate ON
Enable Concatenate mode. The concatenate mode allows the M3000 to accumulate multiple Code 39 bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 39 label containing a leading space is read, the M3000 beeps twice and buffers the data without transmission. This process continues until a Code 39 label without a leading space is read or 128 characters are buffered. A Code 39 bar code label that only contains dashes (minus sign) will clear the buffer.
OFF*
Disable Concatenate mode.
UPC Decoder ON*
Enable reading UPC-A and UPC-E labels.
OFF
Disable reading UPC-A and UPC-E labels.
Expand UPC-E (to UPC-A) ON
Convert all UPC-E labels to their UPC-A equivalents before transmission. After conversion, the M3000 follows the UPC-A programming options.
OFF*
No conversions are performed.
Expand UPC-A (to EAN-13) ON
Convert all UPC-A labels to an equivalent EAN-13 format by inserting a leading zero. After conversion, the M3000 follows the EAN-13 programming options.
OFF*
No conversions are performed.
UPC-A # systm (Number System) ON*
Transmit the UPC-A Number System character.
OFF
Do not transmit the UPC-A Number System character.
6-13
Page 82
M3000 Bar Code Reader User's Guide UPC-E # systm (Number System) ON*
Transmit the UPC-E Number System character.
OFF
Do not transmit the UPC-E Number System character.
UPC-A Chkdig (Check Digit) ON*
Transmit the UPC-A Check Digit character.
OFF
Do not transmit the UPC-A Check Digit character.
UPC-E Chkdig (Check Digit) ON*
Transmit the UPC-E Check Digit character.
OFF
Do not transmit the UPC-E Check Digit character.
EAN Decoder ON*
Enable reading EAN-8 and EAN-13 labels.
OFF
Disable reading EAN-8 and EAN-13 labels.
EAN-8 Zrofil (to EAN-13) ON
Add five leading zeroes to EAN-8 labels. After conversion, the M3000 follows the EAN13 programming options.
OFF*
No conversion is performed.
EAN-13 CCode (Country Code) ON*
Transmit the EAN-13 Country Code.
OFF
Do not transmit the EAN-13 Country Code.
EAN-8 CCode (Country Code) ON*
Transmit the EAN-8 Country Code.
OFF
Do not transmit the EAN-8 Country Code.
EAN-13 Chkdig (Check Digit) ON*
Transmit the EAN-13 Check Digit character.
OFF
Do not transmit the EAN-13 Check Digit character.
EAN-8 Chkdig (Check Digit) ON*
Transmit the EAN-8 Check Digit character.
OFF
Do not transmit the EAN-8 Check Digit character.
ISBN # Cnvt (Number Conversion) ON
Convert 13 DIGIT BOOKLAND/EAN (978 prefix) to its corresponding 10 DIGIT ISBN number.
EXAMPLE:
OFF*
6-14
BAR CODE DATA
=
9780806957906
ISBN OUTPUT DATA
=
0806957905
Do not convert Bookland/EAN to an ISBN number.
Page 83
6Setup Procedures
UPC/EAN Addons (SUPPLEMENTS) Decoder ON
Enable reading UPC & EAN supplements.
OFF*
Disable reading UPC & EAN supplements.
ON*
Enable reading 2 digit supplements. Decoder must be set ON.
OFF
Disable reading 2 digit supplements.
ON*
Enable reading 5 digit supplements. Decoder must be set ON.
OFF
Disable reading 5 digit supplements.
2 Digit
5 Digit
Required Specifies how the reader handles various supplements. OFF *
UPC/EAN bar codes are read with or without valid supplements.
UPC
UPC bar codes are not read unless they are accompanied by a valid supplement.
EAN
EAN bar codes are not read unless they are accompanied by a valid supplement.
BOOKLD Bookland EAN bar codes are not read unless they are accompanied by a valid supplement. ALL
UPC/EAN bar codes are not read unless they are accompanied by a valid supplement.
Send Space ON
Insert a space between the standard bar code data and the supplemental data.
OFF*
No separator space is inserted.
I 2 OF 5 Decoder ON*
Enable reading INTERLEAVED 2 of 5 labels.
OFF
Disable reading INTERLEAVED 2 of 5 labels.
Check Digit Specifies which type of check digit is used with INTERLEAVED 2 of 5: NONE* NONE (no check digit required) USS
UNIFORM SYMBOLOGY SPECIFICATION (3-1-3 MOD 10)
OPCC OPTICAL PRODUCT CODE COUNCIL (2-1-2 MOD 10) Send Check ( Digit) ON
Transmit the INTERLEAVED 2 of 5 check digit with the bar code data.
OFF*
The check digit is not transmitted.
6-15
Page 84
M3000 Bar Code Reader User's Guide Fixed Size ON
Read only FIXED LENGTH INTERLEAVED 2 of 5 bar code labels that match the lengths specified in the Fixed Size 1 and 2 options defined below. The check digit can be ON or OFF.
OFF*
Disable FIXED LENGTH mode. Read all INTERLEAVED 2 of 5 labels without regard to length.
FIXED Size 1 (2-60) Sets the first valid FIXED LENGTH for Interleaved 2 of 5. Valid lengths are 2 to 60 characters. By definition, the length of Interleaved 2 of 5 labels are an even number of characters. The default FIXED LENGTH is 6 characters. Fixed Size 1 is disabled when set to 0 characters. FIXED Size 2 (2-60) Sets a second valid FIXED LENGTH for Interleaved 2 of 5. The default length is set to 0 characters (i.e. the second FIXED LENGTH is disabled).
CODABAR Decoder ON *
Enable reading CODABAR labels.
OFF
Disable reading CODABAR labels.
Start/Stop ON
Transmit the CODABAR Start/Stop characters.
OFF *
Do not transmit the CODABAR Start/Stop characters.
CLSI Format ON
The M3000 inserts a blank after the 1st, 5th, and 10th characters of a 14-character CODABAR label. The label length does not include the start and stop characters.
OFF *
Disable CLSI formatting.
CLSI ChkDig ON
Enable the CLSI check digit. When this option is enabled, all fourteen digit numeric bar codes must contain a valid check digit.
OFF*
Disable the CLSI check digit. Check digit verification will not be performed.
CODE 128 Decoder ON *
Enable reading Code 128 labels.
OFF
Disable reading Code 128 labels.
UCC Verify ON
A valid MOD 10 CHECK DIGIT is required on UCC-MOD 10 bar codes. (Applies to 20-digit serial shipping container bar codes.)
OFF *
UCC-MOD 10 bar codes are accepted without a valid MOD 10 CHECK DIGIT.
Send Mod 10 (Check Digit)
6-16
ON *
Transmit the Mod 10 Check Digit with the bar code entry.
OFF
Do not transmit the Mod 10 Check Digit
Page 85
6Setup Procedures
CODE 93 Decoder ON*
Enable reading Code 93 labels.
OFF
Disable reading Code 93 labels.
Concatenate ON
Enable Concatenate mode. The concatenate mode allows the M3000 to concatenate multiple Code 93 bar codes in its buffer, then send them to the computer just like they were a single bar code. When a Code 93 label with a leading space is read, the M3000 beeps twice and buffers the data without transmission. This process continues until a Code 93 label without a leading space is read or 128 characters are buffered. Any Code 93 bar code label that only contains dashes (minus sign) will clear the buffer.
OFF*
Disable Concatenate Mode
MSI/Plessey Decoder ON
Enable reading MSI/PLESSEY labels.
OFF *
Disable reading MSI/PLESSEY labels.
2 Check Dig ON
Two valid check digits are required for each label. The first check digit is defined by Mod 11 Chk below. The second check digit is always MOD 10.
OFF *
One valid check digit is required for each label. The check digit must be MOD 10.
Mod 11 Chk (Check Digit) ON
The First check digit must be MOD 11.
OFF *
The First check digit must be MOD 10.
Send Check 1 ON
Transmit the FIRST CHECK DIGIT.
OFF *
Do not transmit the FIRST CHECK DIGIT.
Send Check 2 ON
Transmit the SECOND CHECK DIGIT.
OFF *
Do not transmit the SECOND CHECK DIGIT.
ON
Enable reading of Modified Plessey ISBN bar codes. Only eleven digit ISBN bar codes are be read.
OFF*
Do not read Modified Plessey ISBN bar codes.
ISBN
6-17
Page 86
M3000 Bar Code Reader User's Guide
Code 11 Decoder ON
Enable reading Code 11 labels.
OFF *
Disable reading Code 11 labels.
2 Check Dig ON
Two valid check digits are required for each label.
OFF *
One valid check digit is required for each label.
Send Check 1 ON
Transmit the FIRST CHECK DIGIT.
OFF *
Do not transmit the FIRST CHECK DIGIT.
Send Check 2 ON
Transmit the SECOND CHECK DIGIT.
OFF *
Do not transmit the SECOND CHECK DIGIT.
Termination Character The optional TERMINATION CHARACTER is transmitted at the end of the bar code data. This option is applicable only during non portable mode operation. You can select from the following termination character options: Termination Char NONE TAB
(ASCII 09)
CR*
(CARRIAGE RETURN, ASCII 13)
LF
(LINE FEED, ASCII 10)
CR + LF (CARRIAGE RETURN & LINE FEED, ASCII 13 & ASCII 10) USER
Selects the user defined termination character (00H - F9H).
User Term Valid only if Termination Char is set to USER. Override
6-18
ON
If any control character or special character (i.e., function key, arrow key, etc.) is embedded in the bar code data, the Preamble, Postamble, and the TERMINATION CHARACTER are not transmitted.
OFF *
The Preamble, Postamble TERMINATION CHARACTER will be transmitted with all bar code data.
Page 87
6Setup Procedures
Preamble Preamble refers to a user-defined set of characters transmitted before the bar code data. The preamble is active only during Non Portable mode operation. Enter Preamble This set of user-defined characters is transmitted at the beginning of bar code data. To define this preamble, enter the ASCII characters from the keypad and press ENTER. Refer to Appendix K, M3000 ASCII Character Chart, for specific code definitions. Send Delay (0.0 - 9.9 SEC) This option specifies the amount of delay that occurs after the bar code preamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. The default is 0.0 seconds.
Postamble Postamble refers to a user-defined set of characters transmitted after the bar code data and before the termination character. The postamble is active only during Non Portable mode operation. Enter Postamble This set of user-defined characters is transmitted at the end of bar code data. To define this postamble, enter the ASCII characters from the keypad and press ENTER. Refer to Appendix K, M3000 ASCII Character Chart, for specific code definitions. Send Delay (0.0 - 9.9 SEC) This option specifies the amount of delay that occurs after the bar code postamble is transmitted. The delay period is programmable from 0.0 to 9.9 seconds. The default is 0.0 seconds.
Bar Code Edit Must be ON for any of the editing options below to be valid. Editing can apply to either ALL bar code types or one Bar Code type. The default is ALL, Bar Code types. Editing ON
Enable Bar Code Editing.
OFF *
Disable Bar Code Editing.
Lead Strip (Leading Strip) (0-30) Editing must be ON. Refers to the number (0-30) of bar code characters to be stripped, or removed from the beginning of the Bar Code data. Trail Strip (Trailing Strip) (0-30) Editing must be ON. Refers to the number (0-30) of bar code characters to be stripped, or removed from the end of the Bar Code data. NOTE: If the total number of strip characters (both Leading and Trailing) is greater than the number of characters of the bar code, no characters will be stripped. Space Strip Editing must be ON. ON
Any LEADING & TRAILING SPACES are stripped from the data.
OFF *
No spaces are stripped.
6-19
Page 88
M3000 Bar Code Reader User's Guide Code Editing must be ON. Refers to which bar code type Bar Code Edit enables. The choices are listed below: CODE 39 UPC-A UPC-E EAN-13 EAN-8 INTERLEAVED 2 of 5
CODABAR CODE 128 CODE 93 MSI CODE 11 ALL*
Bar Code Beeper The following settings allow you to set the Tone or pitch, and the Length or duration of the beeps emitted from the M3000 while scanning bar codes.. Tone NONE LOW MEDIUM* HIGH Length SHORTEST SHORT* LONG LONGEST
Laser/CCD Opts (Options) Timeout If the LASER or CCD does not read a bar code within the designated time period, the device is turned off. Select from OFF, or 1 to 9 seconds; the default is 1 second. CAUTION: IF THE ABOVE OPTION IS SET TO OFF, IT WILL OVERRIDE THIS SAFETY FEATURE. OFF 1-9 Sec Trigger Off ON *
Releasing the trigger turns off the LASER or CCD.
OFF
The LASER or CCD continues to run until a successful read or until the Timeout period lapses.
NOTE: To use "Blink Mode" with a CCD or laser, set this option OFF, and LASER/CCD Always Run option ON. (Note that "Blink Mode" does not operate properly for lasers that employ thermal shut-down.) Always Run
6-20
ON
The Laser or CCD runs continuously as long as the trigger is pulled. The scanner is not affected by the LASER/CCD Timeout and does not shut off after a "good read".
OFF *
The Laser or CCD runs only when the trigger is pulled. (The LASER/CCD Timeout option remains in effect.)