Page 69
6Setup Procedures Introduction to Setup The M3000 SETUP FUNCTION is used to configure all system-wide parameters such as: • • • • •
Date & Time Non-Portable Mode Keyboard Wedge Bar Code Reader Communications
The following Setup Selection charts detail the M3000 setup options. Unless otherwise indicated, defaults are marked by "*". Those defaults not marked by "*" are explained in the Description column. Upon EXIT from FUNCTION SETUP, all parameter changes take effect and remain in effect until FUNCTION SETUP is re-entered and new changes are made. Setup parameters are not affected by shutting off the M3000. The SETUP FUNCTION parameters are crucial to M3000 operation, so SETUP can be password protected.
Changing Setup To access Setup from the Portable mode just press SETUP. From Non Portable Modes, press FUNC SETUP. The display shows:
Setup Selection >Date/Time Setup options are accessed by menus. Use the following keys to move from one menu level to another, or from option to option within a menu: Key
Function
↵
ENTER is used to select the current menu category. Up or Down arrows are used to move through menu categories at the current level. Left or Right arrows are used to cycle through, and select options at menu levels 3 and 4.
EXIT
Is used to return to the next higher menu level, and to leave the Setup Selection Function.
For example: To change the Serial Port Baud Rate setting from the default 9600 to 2400, press the following keys: SETUP EXIT EXIT ↵ This means: Enter Setup by pressing SETUP, or FUNC then SETUP depending on the current menu location, followed by 3 down arrows, ENTER, 2 down arrows, 2 left arrows and finally 2 EXIT key presses.
6-1
Page 70
M3000 Bar Code Reader User's Guide The cursor in the lower left corner of the display also indicates which key to press. The following chart explains the meaning of the cursors that affect menus: Cursor
> ➡
Function
The greater than cursor is used to indicate a menu category. ENTER- selects the category. Up/Down arrows- scroll through the categories. The arrow cursor is used to indicate that the Left/Right arrow keys are used to scroll between options.
Anytime you enter data instead of using arrow keys to select the data, you must press ENTER before pressing EXIT or the data will not be saved.
6-2
Page 71
6Setup Procedures
FUNC + SETUP Setup Selection > Menu Level 1 Date/Time
↵
➡ Menu Level 2 Set Date & Time
➡ Menu Level 3
(Use arrow keys to select digit to change and press numeric key for new value.)
01/01/92 08:00 Nonport. Mode
↵
Nonportable Mode
KEYBOARD WEDGE * SERIAL WEDGE RS232 SERIAL
Keyboard Wedge
↵
Type
IBM AT * PS/2 25, 30 PS/ OTHER IBM PC/XT
Keybd
USA* FRENCH GERMAN ITALIAN UNIVERSAL
Output
SLOWEST SLOW FAST FASTEST*
Auto Caps
ON*/OFF
Caps Lock
ON*/OFF
Num Lock
ON/OFF*
Scan Set #3
ON/OFF*
Protocol
NONE* XON/OFF
Output
ASCII* PCSCAN
Baud Rate
300 600 1200 2400 4800 9600* 19200 38400 7 8*
Serial Port
↵
Data Bits
Description (if required)
Parity
NONE* ODD EVEN MARK
Stop Bits
1* 2
Char Delay
0ms - 99ms
Duplex
FULL* HALF
Caps Lock
ON*/OFF
Num Lock
ON/OFF*
Serial Beep
ON*/OFF
Default = 1ms
6-3
Page 72
M3000 Bar Code Reader User's Guide Auto Advance
6-4
ON/OFF*
Page 73
6Setup Procedures
FUNC + SETUP Setup Selection (Continued) > Menu Level 1
Bar Codes
> Menu Level 2
↵
➡
Menu Level 3
➡ Menu Level 4
Decoder Full ASCII Check Digit Send Check Concatenate Decoder Expand UPCE Expand UPCA UPCA #systm UPCE #systm UPCA Chkdig UPCE Chkdig
ON*/OFF ON/OFF* ON/OFF* ON/OFF* ON/OFF* ON*/OFF ON/OFF* ON/OFF* ON*/OFF ON*/OFF ON*/OFF ON*/OFF
Code 39
↵
UPC
↵
EAN
↵
Decoder EAN8 Zrofil EAN13 CCode EAN8 CCode EAN13 Chkdig EAN8 Chkdig ISBN # Cnvt
ON*/OFF ON/OFF* ON*/OFF ON*/OFF ON*/OFF ON*/OFF ON/OFF*
UPC/EAN Addons
↵
Decoder 2 Digit 5 Digit Required
I 2 of 5
↵
ON/OFF* ON*/OFF ON*/OFF OFF* UPC EAN BOOKLD ALL ON/OFF* ON*/OFF NONE*
Send Space Decoder Check Digt
Description (if required)
USS Send Check Fixed Size Fixed Size 1 Fixed Size 2
OPCC ON/OFF* ON/OFF* 2-60 2-60
Decoder Start/Stop CLSI Format CLSI Chk Dig Decoder UCC Verify Send Mod 10
ON*/OFF ON/OFF* ON/OFF* ON/OFF* ON*/OFF ON/OFF* ON*/OFF
Codabar
↵
Code 128
↵
Code 93
↵
Decoder Concatenate
ON*/OFF ON/OFF*
MSI/Plessey
↵
Decoder 2 Check Dig Mod 11 Chk Send Check 1 Send Check 2 ISBN
ON/OFF* ON/OFF* ON/OFF* ON/OFF* ON/OFF* ON/OFF*
Code 11
↵
Decoder 2 Check Dig Send Check 1 Send Check 2
ON/OFF* ON/OFF* ON/OFF* ON/OFF*
Termination Char
↵
Termination Char
NONE, TAB, CR*, LF, CR+LF,USER 00H - F9H ON/OFF*
User Term Override
Fixed Size 1 default = 6 Fixed Size 2 default = 0
6-5
Page 74
M3000 Bar Code Reader User's Guide
FUNC + SETUP Setup Selection (Continued) > Menu Level 1
> Menu Level 2
Bar Codes (Continued)
Preamble Postamble
➡
Menu Level 3
➡ Menu Level 4
Description (if required)
↵
Enter Preamble Send Delay
0-31 char. 0.0s - 9.9s
Default = 0
0-31 char. 0.0s - 9.9s
Default = 0
↵
Enter Postamble Send Delay
Bar Code Edit
↵
Editing Lead Strip Trail Strip Space Strip Code
ON/OFF* 0 - 30, 0* 0 - 30, 0* ON/OFF* (See description) Default = ALL
Editing affects ALL Bar Code types if ON, or the Bar Code selected at the Code option, No Bar Codes are affected if Editing is OFF. Valid Bar Codes are: Code 39, UPC-A, UPC-E, EAN13, EAN-8, I 2 OF 5, CODABAR, CODE 128, CODE 93, MSI, CODE 11, OR ALL.
Bar Code Beeper
↵
Tone
LOW-HIGHEST & NONE SHORTESTLONGEST
Default = MEDIUM
Timeout
1 Sec - 9 Sec & OFF
Default = 1
Trigger Off Always Run Read Delay Bar Code ID Dupli Reads F1-F10 Keys Specl Keys
ON*/OFF ON/OFF* 1.0s - 0.9s
Default = 1.0
Length Laser/CCD Opts
Other Options
> Menu Level 1 Transmit Setup
↵
↵
➡ Menu Level 2
➡ Menu Level 3
Data
MENU*/SEND ALL
Mode
Dialing
MENU* KBD WEDGE SER WEDGE RS232 PORT MODEM TONE*/PULSE
Phone Number
(Enter Dialing Text)
Protocol
NONE* XON/XOFF XMODEM
Output
ASCII* PCSCAN
Baud Rate
300 600 1200 2400 4800 9600* 19200 38400 7 or 8*
Data Bits
6-6
↵
Default = SHORT
ON/OFF* ON*/OFF ON/OFF* ON/OFF* Description (if required)
Press ENTER to save dialing text.
Page 75
6Setup Procedures
FUNC + SETUP Setup Selection (Continued) > Menu Level 1 Transmit Setup (Continued)
Other Setup
↵
↵
↵
➡ Menu Level 2
➡ Menu Level 3
Parity
NONE* ODD EVEN
Stop Bits
1* or 2
Char Delay
0ms - 99ms
Duplex
FULL */HALF
Modem TmOut
ON/OFF*
Caps Lock
ON*/OFF
Num Lock
ON/OFF*
SOT Text
Not Required 0 - 250 characters
Alpha, numeric, and all other ASCII characters allowed.
SOT Delay
0 - 9.9 seconds 1 - 2 characters allowed
Default - 0 Sec
EOT Text
Not Required 0 - 250 characters
Alpha, numeric, and all other ASCII characters allowed.
EOT Delay
Default - 0 Sec
Timeout
0 - 9.9 seconds 1 - 2 characters allowed 1Min - 99 Min/OFF
Password
ON/OFF*
Setup Password = OK
Auto Input
ON/OFF*
Auto Save
ON/OFF*
Automatically saves the data file on EXIT.
View Delay
0.0 to 9.9 seconds
Default = 0.5 Sec
Overwrite
ON*/OFF
Enables and disables bar code and serial data overwriting of data in the current input.
Halt On Err
ON/OFF*
Enables and disables the halting of M3000 operation when an error is encountered.
Wedge Kypad
ON/OFF*
Wedge Kypad enables and disables keypad output directly from the M3000 during any wedge mode operations.
Reset All Setups To Default?
YES (to reset)
Enter YES to reset to defaults or press EXIT to leave settings in current state.
Description (if required)
Default = 1 ms
Default = 4 Min 15 Sec When set to "OFF" in Modem Receive mode, M3000 waits indefinitely for a call.
Default = 5 Min
Reset Setups
Setup Categories The information that follows provides additional information about the M3000 menus. The menus are arranged by categories and options in the order presented in the preceding charts.
Date/Time When you select Date/Time from the Setup Selection menu, the M3000 displays the date and time in the following 24 hour format: month/day/year hour:minute (mm/dd/yy, hh:mm)
6-7
Page 76
M3000 Bar Code Reader User's Guide All hours past noon must be entered in the range 13-23. When you press ENTER to select a time change, the M3000 resets seconds to zero.
Non Portable Mode (Nonport. Mode) Pressing the SHIFT key from the "Portable Mode Selection Function" display places the M3000 in one of three non portable modes. The availability of the these modes is dependent on the non portable mode selected with this option. The non portable modes designate how the M3000 sends data to the personal computer, or host computer. Only bar code data is sent. Data is not sent from the M3000 keypad. For information on Data File Transmissions, refer to Transmission Setup. The automatic shut-off feature is disabled during all non portable operations.
Keyboard Wedge The default non portable mode is Keyboard Wedge. When the Keyboard Wedge Y-cable is connected, the M3000 switches to the Keyboard Wedge mode automatically, regardless of the Non Portable mode setting. During Keyboard Wedge operation the M3000 receives all its power from the keyboard port, and does not use its internal battery. Keyboard Wedge setup options must match your current computer configuration. When connected as a Keyboard Wedge, the M3000 always turns ON and OFF with the computer.
Serial Wedge When used as a Serial Wedge, the M3000 sends bar code data to the host computer just as if the data were typed from the terminal keyboard. Serial Wedge operation is enabled by the following conditions: •
Connection of the Serial Y-cable
•
Serial Wedge selected as the Non Portable mode
•
M3000 Serial Port settings match comparable settings on the host computer.
•
The SHIFT key is pressed from the "Portable Mode Select Function" display
Pressing SHIFT again, returns you to the portable mode. NOTE: During Serial Wedge and RS-232 Serial operation, the M3000 operates on either battery power or the external power supply. We recommend you use the external power supply that was shipped with your M3000, if you intend to operate in the serial modes for any extended period of time. Extended use in these non portable modes without the external power supply installed, reduces battery life.
RS232 Serial When used in the RS232 Serial mode, the M3000 sends bar code data to any RS-232 Serial Port. When using SOFTCOM keyboard emulation software with any DOS based computer, the RS-232 data appears just as if it were typed from the computer keyboard. RS232 Serial operation is enabled by the following conditions: •
Connection of the Serial cable
•
RS-232 Serial selected as the Non Portable mode
•
M3000 Serial Port settings match comparable settings on the receiving computer
•
Proper installation of SOFTCOM keyboard emulation software (if needed).
•
The SHIFT key is pressed from the "Portable Mode Select Function" display
Pressing SHIFT again, returns you to the portable mode. 6-8
Page 77
6Setup Procedures
NOTE: During Serial Wedge and RS-232 Serial operation, the M3000 operates on either battery power or the external power supply. We recommend you use the external power supply that was shipped with your M3000, if you intend to operate in the serial modes for any extended period of time. Extended use in these non portable modes without the external power supply installed, reduces battery life.
Keyboard Wedge This option defines the type of computer, the type of keyboard and proper keyboard/computer output settings. The selections must be made properly for the data to transmit correctly. NOTE: The UNIVERSAL keyboard setting below, can be used for all international keyboards.
Type Defaults are indicated by (*). Select the type of computer that matches the computer you connected to the M3000. IBM AT (286, 386, and 486 processors)* IBM PS/2 MODELS 25, 30, 56, 57, 90 (& some MODEL 70's) IBM PS/2 MODELS 30-286, 50, 55, 60, 70 & 80 IBM PC/XT (8088 and 8086 processors)
Keyboard (Keybd) Select from the following keyboard types. USA* FRENCH GERMAN ITALIAN UNIVERSAL NOTE: For all PC/XT computers, select UNIVERSAL as the KEYBOARD TYPE to ensure proper upper/lower case transmission.
Output This option sets the speed at which keyboard data is transmitted to the computer. Some computer systems may require slower transmission speeds. The default setting is FASTEST. SLOWEST SLOW FAST FASTEST*
Auto Caps With this option ON, the M3000 automatically transmits data in the correct upper and lower case, whether the keyboard's settings are turned ON or OFF. ON *
Enable Auto Caps.
OFF
Disable Auto Caps
NOTE: The Auto Caps option is NOT effective on some computers, such as XT's. Indications that this option is NOT functioning include either the reversal of Upper/Lower Case text, or the absence of data transmission from the M3000.
6-9
Page 78
M3000 Bar Code Reader User's Guide If the Auto Caps option is not operating properly on your system, take the following steps: 1.
Set Auto Caps to OFF.
2.
Set Num Lock to match your computer's Num Lock status.
3.
Set Caps Lock to match your computer's Caps Lock status. or
1.
Set Auto Caps to OFF.
2.
Set Keyboard to UNIVERSAL
Caps Lock Setting this function is necessary only if the Auto Caps option does not operate on your computer. See Auto Caps option to determine whether the Caps Lock option setting is required. To use this option, select either ON or OFF to match the computer keyboard's CAPS LOCK status. ON *
Select ON when the computer keyboard's CAPS LOCK is turned ON. This setting transmits lower case Alpha characters as Shifted characters.
OFF
Select OFF when the computer keyboard's CAPS LOCK is turned OFF. This setting transmits upper case Alpha characters as Shifted characters.
Num Lock Setting this function is necessary only if the Auto Caps option does not operate on your computer. See Auto Caps option to determine whether the Num Lock option setting is required. To use this option, select either ON or OFF to match the computer keyboard's NUM LOCK status. ON
Select ON when the computer keyboard's NUM LOCK is turned ON.
OFF *
Select OFF when the computer keyboard's NUM LOCK is turned OFF.
Scan Set 3 This option is necessary ONLY for computers that use Scan Set 3(XWINDOW Terminals). You may need to disable Auto Caps. ON
Enable Scan Code Set 3.
OFF *
Disable Scan Code Set 3
Serial Port The M3000's RS-232C serial port transmits bar code data to the attached computer's serial interface. Serial Port settings must match the settings of the attached computer. NOTE: Serial Port Setup is used for Non Portable and Serial Input modes only, and is not used to control FUNC XMIT. Refer to Transmit Setup.
6-10