Page 59

5Programming

Input Type This defines the type of entry the M3000 requires for input during data entry. The allowable Input Types are: D

Data Input

- requires standard data input from the keyboard or scanning device.

S

Stamp Input

- records date & time information from the M3000's internal realtime clock without the requirement for operator input.

Y

YES/NO

- requires Y or YES, N or NO response from the user during input.

E

Exhibit

- displays only a prompt (does not perform data input)

N

No Edit

- data can be entered one time only, and once entered cannot be edited, otherwise it is the same as a Data Input.

Field Requirements: Input of a D, S, Y, E, or N is required. NOTE: If "Input Type" is set to 'N' and, "Use Receive Data Files Only" is set to 'Y', and "Auto Advance" is set to 'Y' then the cursor automatically advances past any imported data and stops in the next input that requires user input.

Prompt The prompt is a sequence of characters that is displayed to identify an input, so the operator knows what data is required. The data entry window follows immediately after the Prompt. Place a space at the end of a Prompt to separate the Prompt from the data collection window. If you want a Prompt on the top line and the data entry on the bottom line, add spaces to the end of the Prompt until there is a total of sixteen Prompt characters as shown in the following example. You will be prompted to enter a prompt only if the Input Type is D, Y, or N.

Enter Spaces after prompt text to force input data to the next row Sample Prompt Text

P a r t

Enter Spaces Here

N u m b e r

.... To cause data to display Here Field Requirements: • •

0 to 31 characters allowed alpha, numeric, and all other ASCII characters are accepted

NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. Refer to Appendix K for Special Character values.

Stamp Commands Date and Time Stamp inputs embed commands in the program which read selected information from the system clock/calendar into the data file. The data file is imprinted with the information from the clock when the data is first collected. When reviewing data, the data file will not be re-stamped. The date and time stamp input cannot be edited during data collection and is entirely transparent to the operator running this program. Additional characters can be intermixed with the Stamp Commands to provide formatted 5-17

Page 60

M3000 Bar Code Reader User's Guide output. You will be prompted to enter stamp commands only if the Input Type is S. The Stamp Commands are: M D Y H I S W

- Month (01-12) - Day of Month (01-31) - Year (00-99) - Hour (00-23) - Minute (00-59) - Second (00-59) - Day of Week (0-6)

NOTE: The output during transmission will be two numeric digits for all the commands except W, Day of Week. The Day of Week is output as one numeric digit, 0 being Sunday and 6 being Saturday. For Example: To create a date stamp that outputs MM/DD/YY HH:MM, Enter S, as the Input Type and enter the following Stamp Commands:

Stamp Commands M//D//Y H:I Field Requirements: • •

Stamp Commands are not required 0 to 31 characters allowed

Exhibit Text This is a sequence of characters that is displayed on the screen only and does no user input. Enter the text to be displayed. You will be prompted to enter Exhibit Text, only if the Input Type is E. Field Requirements: • • •

Exhibit Text is not required 0 to 31 characters allowed alpha, numeric, and all other ASCII characters are accepted

NOTE: Any ASCII control character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. Refer to Appendix K for Special Character values.

Screen Usage Parameters The following four parameters specify the portion of the screen used by the current input definition. These parameters must be defined when using a Data Input, Yes/No Input, or Exhibit Text. NOTE: The M3000 prevents the operator from specifying a starting position greater than the ending position. If the prompt text is greater than or equal to the window defined, the M3000 displays only part of the prompt and allows one space for the input window.

5-18

Page 61

5Programming

Str Row Start row defines whether the first displayed character of the Input Prompt and data entry window is displayed on Row 0 or Row 1. Row 0 is the top line of the two row display, and Row 1 is the bottom line of the two row display. Field Requirements: • •

Str Row is required numeric data accepted (0-1)

Str Col Start column defines the column location on the Start Row, of the first displayed character of the Input Prompt and data entry window. The M3000 display uses 16 columns, numbered 0 to 15. Field Requirements: • •

Str Col is required numeric data accepted (0-15)

End Row End Row defines whether the last displayed character of the Input Prompt and data entry window is displayed on Row 0 or Row 1. Row 0 is the top line of the two row display, and Row 1 is the bottom line of the two row display. Field Requirements: • •

End Row is required numeric data accepted (0-1)

End Col End column defines the column location on the End Row, of the last displayed character of the Input Prompt and data entry window. The M3000 display uses 16 columns, numbered 0 to 15. Field Requirements: • •

End Col is required numeric data accepted (0-15)

5-19

Page 62

M3000 Bar Code Reader User's Guide

Single Input Using Entire Display_________________________________________

Screen Specifications:

Note: Use the Left and Right Arrow Keys to scroll Input Data across the Input Window.

Prompt 1 = "Item Number" + Blank Space New Screen = Yes Str Row = 0 Str Col = 0 End Row = 0 End Col = 15

Two Inputs on One Screen ______________________________________________ Prompt 1

Input Window 1 Input Data Extends Outside the Windows

Row 0 Row 1 Prompt 2 Screen Specifications:

Input Window 2 Note: Use the Left and Right Arrow Keys to scroll Input Data across the Input Window.

Prompt 1 = "Item #" + Blank Space New Screen = Yes Str Row = 0 Str Col = 0 End Row = 0 End Col = 15 Prompt 2 = "Qty" + Blank Space New Screen = No Str Row = 1 Str Col = 0 End Row = 1 End Col = 9

Three Inputs on One Screen _____________________________________________ Prompt 1

Input Window 1

Row 0 Row 1 Prompt 2

Input Window 2

Screen Specifications: Prompt 1 = "Item #" + Blank Space New Screen = Yes Str Row = 0 Str Col = 0 End Row = 0 End Col = 15 Prompt 2 = "Qty" + Blank Space New Screen = No Str Row = 1 Str Col = 0 End Row = 1 End Col = 7 Prompt 3 = "LOC" + Blank Space New Screen = No Str Row = 1 Str Col = 9 End Row = 1 End Col =15

5-20

Prompt 3

Input Window 3 Note: Use the Left and Right Arrow Keys to scroll Input Data across the Input Window.

Page 63

5Programming

Data Input Parameters The parameters that follow establish the acceptable ranges of data input for the current field. These parameters include: Input Size Max? Require Input? Display Pattern Shift Input Data to Upper Case? Bar Code Types Default Data Lookup Tbl/File

Input Size Min? Auto Advance? Input Mask Input Source Bar Code Auto Advance Bar Code Append

Input Size Max Input Size Max specifies the maximum number of characters that can be entered into this field while collecting data. It is a 3 digit field, 0 - 250 characters in length. Field Requirements: • • • maximum input size must be specified 3 digit field valid input size, 0-250 characters in length.

NOTE: The M3000 will prevent the operator from specifying a maximum input size less than the minimum input size.

Input Size Min Input Size Min specifies the minimum number of characters that can be entered into this field while collecting data. It is a 3 digit field, 0 - 250 characters in length. Field Requirements: • • • minimum input size must be specified 3 digit field valid input size, 0-250 characters in length.

NOTE: The M3000 will prevent the operator from specifying a minimum input size greater than the maximum input size.

Require Input? Some inputs such as a quantity field, can require the operator to enter data before advancing to the next input. Other inputs, such as a description field, can be optional. If you want the input field to require data, enter Y or YES, otherwise enter N or NO. Field Requirements: YES or NO (Y or N) input required NOTE: If the Require Input is Y, the minimum size of the input must be satisfied before advancing to the next input.

Auto Advance? Sometimes you may want an input to advance to the next input without requiring the operator to press the ENTER key. If you want this input to automatically advance to the next field when the Input Size Max has been reached, enter Y. Field Requirements: YES or NO (Y or N) input required

5-21

Page 64

M3000 Bar Code Reader User's Guide

Display Pattern Use this option when fill-in-the-blank inputs are required. When used with an Input Mask you can specify whether display characters in the data entry window are overwritten during data entry, or fixed and therefore not overwritten. For example, if you have a ten digit part number and you want the pound sign # displayed in the Part Number Window, enter 10 pound signs (SHIFT O) as the display pattern. Control characters entered in a display pattern, are displayed as solid boxes.

Col 15

Col 0

P a r t

N u m b e r

# # # # # # # # # # Display pattern of 10 pound signs Field Requirements: • • • a DISPLAY PATTERN is not required 0 to 32 characters allowed alpha, numeric, and all other ASCII characters are accepted

NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. Refer to Appendix K for Special Character values.

Input Mask Input Mask defines what type of characters are allowed during data entry, and also defines the usage of the Display Pattern if one is being used. Use the "FIXED" and "INCLUDE" mask characters in conjunction with the Display Pattern to indicate Display Pattern characters which will not be overwritten. The characters specified in the Input Mask as INCLUDE will be included with the data during transmission. The characters specified as FIXED will not be included with the data during transmission. Note that the last Input Mask character specified (A, N, or D only) validates all remaining characters during data entry . Mask Characters: A - Alphanumeric (HEX 20H-7EH) N - Numeric (0-9) D - Decimal (0-9,+,-,.) F - Fixed (the DISPLAY PATTERN character is FIXED) I - Include (the DISPLAY PATTERN character is FIXED and is INCLUDED during transmit.) Field Requirements: • •

Input Mask is required 1 to 32 characters allowed

To define an entire input as alphanumeric, specify the mask character "A". To define an alphanumeric part number in which the second character must always be numeric, specify the mask as "ANA". The second A specifies all following characters must be alphanumeric. NOTE: The Input Mask defines the character attributes for each input character for the first 32 characters of an input. The last Input Mask character specified (A, N, or D only) validates all input characters beyond the 32nd character.

5-22

Page 65

5Programming To define an all numeric part number with dashes as fixed characters, the Input Mask could be "NNNFNNFNNNN". The corresponding DISPLAY pattern should be used so the operator knows where to input information. This input could be ###-##-####. When the operator is collecting information, he will not be able to overwrite the dashes, the cursor actually skips over them. If you want to include the dashes during file transmission, specify an Input Mask of "NNNINNINNNN".

Note that these are not required.

Shift Input Data to Upper Case This input allows the conversion of all input text to be converted to upper case. Press "Y" or "YES" to convert all input text to upper case. Field Requirements:

YES or NO (Y or N) input required.

Input Source K, B, S, or X This input specifies the valid sources of data for the current input. Press "K" to accept only keyboard data, "B" to accept keyboard or bar code, "S" to accept keyboard or RS-232 serial input, or press "X" to accept all input types. For more information on using RS-232 serial input, refer to Chapter 8, Advanced Operations. Field Requirements: K, B, S or X input is required. NOTE: Enabling RS-232 serial input reduces battery life. To achieve maximum battery performance, select RS-232 serial input only when actually needed.

Bar Code Types This input defines an alpha character for each type of bar code allowed during data entry. To require the operator to read only Code 39 bar codes, enter "A" as the bar code type. To require the operator to read UPC-A, UPC-E, and Code 128, enter "BCH" as the bar code types. A C E G I K

- Code 39 - UPC-E - EAN-8 - Codabar - Code 93 - Code 11

B D F H J X

- UPC-A - EAN-13 - Interleaved 2 of 5 - Code 128 - MSI/Plessey - ALL BAR CODE TYPES 5-23

Page 66

M3000 Bar Code Reader User's Guide Field Requirements: • •

Bar Code Types is required 1 to 11 characters allowed

NOTE: This does not enable or disable any bar code decoders that have been selected in the M3000 SETUP function. This only specifies which bar codes are allowed at this input. If a bar code is scanned by the operator that is not an allowed Bar Code Type, the M3000 will sound three long beeps, display an error message, and will not accept the bar code.

Bar Code Append Bar Code Append allows the operator to scan multiple bar codes into the current input field. The operator must press the ENTER key, or scan a Carriage Return (ASCII 13 ) bar code to advance to the next input. Scanning a Back Space (ASCII 8) bar code clears the current input field. Field Requirements: YES or NO (Y or N) input required

Bar Code Auto Advance This feature allows the operator to scan bar codes and advance to the next input without having to press any keys on the keyboard. When Bar Code Auto Advance is specified YES or Y, the M3000 appends a carriage return to the end of the bar code data. The operator must scan a valid input before the M3000 will advance to the next input. Field Requirements: YES or NO (Y or N) input required

Allow Duplicate Inputs This feature allows the operator to scan duplicate bar codes (ar codes having the same data) during input. Field Requirements: YES or NO (Y or N) input required

Default Data Default Data is a sequence of characters that appears automatically the first time an input is presented for data entry. For example, if the Default Data input is specified as "100", the operator sees "100" on this input for each record, and has the choice of accepting or changing the input. By specifying the @ as the Input Data, the M3000 defaults to the data or value that is in this input's previous record. Subsequent records continue to use the most recently entered data as the Default Data value until the operator enters a new value. Any characters defined after the @, as in "@123", are used as the default on the first occurrence of this input. For example, if you want the operator to see "123" in this input, you would type in "@123". If the operator changed the characters in this input from "123" to "ABC", this input field then defaults to "ABC" for each subsequent entry. If a default from previous entry is used on the first input on a new screen, and menu option "Auto Advance" is set to ON, the M3000 will automatically advance the cursor past the default data and stop in the next input when the number of digits in the default data satisfies the input field requirements. If users need to change the default they can use the cursor keys to enter the default data field and manually input the new value. NOTE: If you want to default using the @ character as the first character of your default data, specify the null character "/00" as the first character of the default data field. Field Requirements: • Default Data is not required • 0 to 32 maximum characters allowed • alpha, numeric, and all other ASCII characters are accepted

5-24

Page 67

5Programming NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. Refer to Appendix K for Special Character values. Auto Advance on Default Data When you want to 'Default Data' in an input, you can force the cursor to automatically advance past the default data and stop in the next input. To force auto advance on default data: Enter a /0D (carriage return) after the last character of the default data. NOTE: For this feature to be effective, the input must be defined as the first input of the display after a "New Screen" has been created.

Lookup Tbl/File This input allows the programmer of an M3000 program to define lookup parameters for Lookup Tables, and Lookup Files. For more information on using this feature, refer to Chapter 8, Advanced Operations.

Enable Input Transmit You have the option of controlling which inputs are transmitted with a data file and which inputs are not transmitted. By default this option is set to 'Yes' and the display shows:

Enable Input Transmit? Y When you want the user to collect data on an input field during FUNCTION INPUT, but you do not want the input transmitted with the data file, change this setting to 'No'. This option can be useful on 'Description' and 'Comment' fields where the optional information is helpful to the user, but not needed by the central database. This option is also useful when using embedded header inputs.

Data Output Parameters The following five parameters control the formatting of the output data, and specifications for control characters that are transmitted with the data file. The data output parameters include: Enable Input Transmit Prefix Suffix

Output Format V, L or R Prefix Delay Suffix Delay

Output Format V,L or R The Output Format defines how the data for this input will be formatted during data transmission. The output formats available are: V

Variable length format will transmit only the data entered by operator.

L

Left justified will transmit the data entered by the operator followed by the number of spaces needed to create a field the size of the maximum input size that is defined for this input (i.e. left justify, space fill).

R

Right justified will transmit the number of zeros needed followed by the data entered by the operator to create a field the size of the maximum input size that is defined for this input (i.e. right justify, zero fill).

Field Requirements: V, L or R is required

Prefix Prefix is a string of characters output before the input field data during transmission. The Prefix is used to specify delimiters between inputs and also define any special keys or data that must prefix

5-25

Page 68

M3000 Bar Code Reader User's Guide the input's data field, and can be used to specify transmit pauses, embedded header inputs, and the data file name. Field Requirements: • • •

Prefix is not required 0 to 32 maximum characters allowed alpha, numeric, and all other ASCII characters are accepted

NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. Function keys may be defined as /F0 through /F9. Function key F10 is defined as /F0. Refer to Appendix K and L for Special Character values.

Prefix Delay The Prefix Delay defines the duration of the time delay that is inserted between the transmission of each character of the Prefix. It is used to slow down the data output rate so the M3000 does not cause a data overrun on the host computer during transmission, especially when transmitting data by keyboard wedge. The time delay is incremented in tenths of a second. Most systems can use a Prefix Delay of zero (0). Field Requirements: • • •

Prefix Delay is required 1 to 2 characters allowed numeric data accepted (0-9)

Suffix The Suffix is a string of characters output after the input field data has been sent during data transmission. The Suffix is used to specify delimiters between fields and also to define any special keys or data that must follow the input data, and can be used to specify transmit pauses, embedded header inputs, and the data file name. The default suffix "/0D", outputs a Carriage Return (ASCII 13). Field Requirements: • • •

Suffix is not required 0 to 32 characters allowed alpha, numeric, and all other ASCII characters are accepted

NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. Function keys may be defined as /F0 through /F9. Function key F10 is defined as /F0. Refer to Appendix K and L for Special Character values.

Suffix Delay The Suffix Delay defines the duration of the time delay that is inserted between the transmission of each character of the Suffix. It is used to slow down the data output rate so the M3000 does not cause a data overrun on the host computer during transmission, especially when transmitting data by keyboard wedge. The time delay is incremented in tenths of a second. Most systems can use a Suffix Delay of zero (0). Field Requirements: • Suffix Delay is required • 1 to 2 characters allowed • numeric data accepted (0-9)

5-26