Page 89
6Setup Procedures Read Delay (0.0 - 9.9 SEC) Valid only if Always Run is ON. This option sets the delay period between successive reads of the same bar code. This allows the removal of the bar code from the scan field without multiple reads. The read delay can be set for 0.0 (no delay) to 9.9 seconds, in tenth of a second increments. The default setting is 1.0 second.
Other Options Bar Code ID ON
Transmit the bar code identifier character at the beginning of the bar code data. There is one space between the ID character and the bar code data. The following characters identify Bar Code ID's: A CODE 39 B UPC-A C UPC-E D EAN-13 E EAN-8 F INTERLEAVED 2 of 5
OFF *
G CODABAR H CODE 128 I CODE 93 J MSI K CODE 11
Do not transmit Bar Code ID
Dupli Reads (Duplicate Reads) ON *
Enable reading the same bar code multiple times.
OFF
Disable reading the same bar code twice in a row.
F1-F10 Keys ON*
Enable reading of FUNCTION KEYS in place of ASCII characters.
OFF
Disable reading of FUNCTION KEYS.
Special Keys ON*
Enable reading of SPECIAL KEYS in place of ASCII characters.
OFF
Disable reading of SPECIAL KEYS.
NOTE: See Appendix L Non-ASCII Special Character Definitions for FUNCTION KEY and SPECIAL CHARACTER definitions.
Transmit Setup The Transmit Setup allows you to specify the type of data the M3000 sends, the mode that transmits the data, and presets features such as dialing type, phone number, and serial communications parameters. NOTE: Transmit Setup is used for FUNC XMIT only, and is not used for Non Portable Modes.
Data Data options are MENU and SEND ALL. The default is MENU. MENU*
Enables the "Upload Selection" menu in the Transmit Mode. This option allows you to select specific data files for transmission.
SEND ALL Bypasses the "Upload Selection" menu, and transmits ALL data files stored in the M3000.
6-21
Page 90
M3000 Bar Code Reader User's Guide
Mode Mode specifies which mode is automatically used when the M3000 transmits data and does not require the operator to specify the transmission mode each time the M3000 transmits data, unless MENU is enabled. MENU* Requires you to manually select one of the following transmission modes each time the M3000 transmits data. KBD WEDGE (KEYBOARD WEDGE) SER WEDGE (SERIAL WEDGE) RS232 PORT MODEM
Dialing Sets the modem for one of the following telephone dial types: TONE* PULSE
Phone Number Sets the destination phone number for modem communications.
Protocol NONE*
No PROTOCOL is used. The serial buffer can contain a maximum of 128 characters.
XON/XOFF
Enables XON/XOFF PROTOCOL. When receiving, the M3000 transmits an XOFF (control S) character to stop incoming serial data. This prevents the serial buffer from overflowing. Once the reader is ready to accept more data, an XON (control Q) character is transmitted to enable reception of more serial data. The XOFF will be transmitted when the buffer fills to 128 characters.
XMODEM
Enable the XMODEM protocol. The M3000 automatically detects and supports XMODEM CRC and XMODEM CHECK SUM. XMODEM protocol is commonly used to ensure data integrity when communicating over phone lines .
Output The Output setting sets the data format for one of the following modes: ASCII*
The mode used with standard ASCII terminals.
PCSCAN This mode is commonly used with "PC Terminals" that transmit PC SCAN Codes to the computer, instead of standard ASCII Codes. Some operating systems that use PCSCAN Codes are: PC-MOS, and CONCURRENT DOS.
Baud Rate The baud rate sets the data transmission speed for the M3000 serial port. The M3000's baud rate must match the baud rate of the attached computer's serial interface. Select one of the following: 300 1200 4800 19200
6-22
600 2400 9600* 38400
Page 91
6Setup Procedures
Data Bits This option sets the character length (number of data bits per character) for the serial data. The M3000's Data Bits setting must match the data bits setting of the attached computer's serial interface. Select one of the following: 7 8*
Parity The M3000's Parity setting must match the parity setting of the attached computer's serial interface. Select one of the following: NONE* ODD
EVEN MARK
Stop Bits This option sets the number of Stop Bit characters for the serial data. Select one of the following: 1* 2
Character Delay (Char Delay) Character Delay (also known as inter character delay) specifies the amount of delay that the M3000 inserts between each transmitted character. This option slows the transmission rate to compensate for slow host computers that require more time to process each character. Default setting = 1 millisecond Programmable range: 0ms - 99ms
Duplex The Duplex setting determines whether the M3000 sends data to the Host only, or to both the Host and Terminal. The M3000's Duplex setting must match the duplex setting of the Terminal's serial interface. FULL* In the Full Duplex mode data is sent only to the Host. The host computer receives the data and echoes it back to the terminal. HALF
In the Half Duplex mode data is sent to both the Host and Terminal at the same time.
Modem TmOut The Modem Time Out, when set to "ON" aborts the Transmit Receive mode after approximately 4 Min. 15 Sec, if a call is not received. The M3000 must be connected to a modem, and operating in the Transmit Receive Mode for this feature to take effect. ON
The M3000 aborts Transmit Receive after approximately 4 Min 15 Sec when a call is not received.
OFF*
The M3000 waits for a call indefinitely.
Caps Lock Use this option to match the terminal keyboard's CAPS LOCK status. ON *
Select ON when the terminal keyboard's CAPS LOCK is turned ON. This setting transmits lower case Alpha characters as Shifted characters.
OFF
Select OFF when the terminal keyboard's CAPS LOCK is turned OFF. This setting transmits upper case Alpha characters as Shifted characters.
6-23
Page 92
M3000 Bar Code Reader User's Guide
Num Lock Use this option to match the terminal keyboard's NUM LOCK status. ON
Select ON when the terminal keyboard's NUM LOCK is turned ON.
OFF *
Select OFF when the terminal keyboard's NUM LOCK is turned OFF.
SOT Text (Start of Transmit) SOT Text (Start of Transmit) Text and special characters in the SOT field are transmitted before any other data during FUNCTION TRANSMIT. The start of transmit text can be any text or special characters that you want transmitted before any data files are transmitted. This string of text or special characters can be used to send commands to your computer so it will be ready for the data file transmission. Field Requirements: SOT is not required 0 to 250 characters allowed Alpha, numeric, and all other ASCII characters are accepted. NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. PC function keys may be defined as /F0 through F9. Function key F10 is defined as /F0. Refer to M3000 User's Guide, Appendix K and L for Special Character values.
SOT Delay The start of transmit text transmit delay defines the amount of time delay that is inserted between each character of the SOT Text during file transmission. This is used to slow down the data output rate so that the M3000 does not generate a data overrun on the host computer during transmission, especially when transmitting data by keyboard wedge. The time delay is in tenths of a second (0.0 - 9.9 seconds). Most systems do not need an SOT Delay. Field Requirements: SOT Delay is required 1 to 2 characters allowed Numeric data accepted (0 to 99), Default is 0.
EOT Text (End of Transmit) EOT Text (End of Transmit) Text and special characters are the last characters transmitted at the end of FUNCTION TRANSMIT. The end of transmit text can be any text or special characters that you want transmitted at the end of FUNCTION TRANSMIT. This string of text or special characters can be used to send commands that close the current data file. Field Requirements: EOT is not required 0 to 250 characters allowed Alpha, numeric, and all other ASCII characters are accepted.
6-24
Page 93
6Setup Procedures
NOTE: Any ASCII character may be input by a 3 character sequence of "/nn" (/nn is the HEX value of the character). Since a / is the start of any HEX value, you must type "//" to output a slash. PC function keys may be defined as /F0 through F9. Function key F10 is defined as /F0. Refer to M3000 User's Guide, Appendix K and L for Special Character values.
EOT Delay The end of transmit text transmit delay defines the amount of time delay that is inserted between each character of the EOT Text during file transmission. This is used to slow down the data output rate so that the M3000 does not generate a data overrun on the host computer during transmission, especially when transmitting data by keyboard wedge. The time delay is in tenths of a second (0.0 - 9.9 seconds). Most systems do not need an EOT Delay. Field Requirements: EOT Delay is required 1 to 2 characters allowed Numeric data accepted (0 to 99) Default is 0
Other Setup Timeout Sets the amount of time the M3000 remains ON after the last activity on the unit. Timeout is disabled while operating in NON PORTABLE modes. Default Timeout is 5 minutes. 1-99 Minutes or OFF.
Password ON
The SETUP mode password must be entered to access the SETUP mode. The SETUP password is "OK". This is a fixed password and cannot be changed.
OFF*
Entry of the SETUP mode password is not required to access the SETUP mode.
Auto Input (Automatic Input) When you select Automatic Input the M3000 automatically loads a program and data file any time FUNC INPUT is selected. Automatic Input uses the first program found in RAM. If no data file exists for the program, the M3000 creates a file named- FILE #1. If a data file, or multiple data files exist for the active program, the M3000 uses the first file created for that program. ON
Enables Auto Input.
OFF*
Disables Auto Input.
ON
Automatically saves the data file when the user exits FUNCTION INPUT.
OFF*
Does not automatically save the data file on EXIT. User must respond to display prompt:
Auto Save
Save Data File?
6-25
Page 94
M3000 Bar Code Reader User's Guide
View Delay (0.0 to 9.9 Seconds) View Delay sets the duration of the displayed characters for bar code data, serial data, and lookup file entries. Field Requirements: Valid duration
-
0 to 9.9 Seconds
Default
-
0.5 Seconds
Overwrite Enables and disables bar code data and serial data overwriting of input data in the current input. ON*
Bar code data and serial data will automatically overwrite the contents of the current input.
OFF
Current input data must be manually deleted before bar code or serial data can be entered at the current input.
Halt On Err Enables and dispables the halting of M3000 operation when an error is encountered. ON
M3000 halts operation when an error condition occurs during operation, and displays the appropriate error message until any key is pressed. Also, any error condition disables the bar code reader input until any key is pressed.
OFF*
M3000 displays a brief error message when an error occurs, then re-displays the current input without user intervention.
Wedge Kypad Wedge Kypad (Wedge Keypad) enables and disables keypad output directly from the M3000 during any wedge mode operations. ON
Keypad output is enabled.
OFF*
Keypad output is disabled.
Reset Setups This option resets all setup options to System Default values.
6-26
Page 95
7Communications Introduction The M3000 supports both on-line communications using the keyboard wedge and wedge emulation using SOFTCOM keyboard emulation software, and file transfers that operate in combination with a PC communications program such as PCOM and the M3000 Programmer. All communications modes depend on properly operating components, including serial ports, cable assemblies, and modems. Serial communication parameters must have exactly the same settings on the M3000 and on the PC's or host's communication software.
Transmitting Files The M3000 allows uploading of data files and uploading and downloading M3000 programs and setup, and lookup files. This chapter explains the M3000 transmit upload, receive, and send menus. The M3000 displays the current name being transmitted and the percentage of the file that has been transmitted. You can abort any transmit or receive operation by pressing ANY key on the keyboard. If transmitting with the serial port, select XMIT before connecting the M3000 to any other device. This will prevent any serial port transients from being interpreted as data characters when the M3000 serial port powers up. Pressing any key on the M3000 during a file transmission will abort the file transmission. NOTE: The M3000 stores all system files in a compressed format. This includes programs, setup files, lookup files and clone files. You can send them to a PC, but you cannot edit them. All systems files are transmitted using the "Send Select" menus. Attempts to view system files will be futile. Your display may show arrays of meaningless ASCII characters, or possibly HEX values depending on the editor in use. If you attempt to edit a system file using a PC editor or file viewer, the system file may become unusable.
Transmit Select >Upload Data Transmit Select>Upload Data gives you the choice of transmitting ALL DATA FILES or transmitting individual program/data files from the M3000. ALL DATA FILES will transmit every data file stored in your M3000. If you want to send data from a specific program, select the program used to enter the data, then choose ALL DATA FILES for that program or select a specific data file saved using that program. When either option is selected, the M3000 will prompt you for one of the following configurations: KEYBOARD WEDGE connects between the keyboard and personal computer. SERAL WEDGE connects in-line between the host computer and any RS232 ASCII terminal. 7-1
Page 96
M3000 Portable Bar Code Reader User's Guide RS232 SERIAL connects to the RS232 port of a personal computer. MODEM connects to a Hayes compatible modem. NOTE: If the M3000 FUNC SETUP, "Transmit Select>Upload Data" has been preset to "All Data Files", all data files in the M3000 will be transmitted and you will not be allowed to select individual data files for transmission. The "Transmit Setup" can also be set to send in a preset transmission mode (i.e. Keyboard Wedge, Serial Wedge...). When the transmission mode is pre-selected, the M3000 will automatically transmit in the preset mode.
Transmit Select >Receive Transmit Select >Receive allows you to receive ASCII files, System Files, and M3000 Clone files.
Receive Select >ASCII Files Receive Select, >ASCII Files allows you to receive individual ASCII files from a computer system. The RECEIVE option does NOT erase any target files UNLESS the file name is exactly the same. For example, if you receive a file named SAMPLE and already had a file with the same name, the target file would be copied over by the source file. With this option, the M3000 will prompt you for either RS232 SERIAL or MODEM mode. Once a selection is made, the "Receive Waiting" message will appear. Once transmission has occurred from the source M3000 or computer, a "Complete" message will appear. After the "Complete" message, the M3000 processes each received file.
Receive Select >System Files Receive Select, >System Files allows you to receive individual M3000 system files from another M3000, or computer system. System files include: programs, setup, lookup, and clone files previously sent from an M3000. The RECEIVE option does NOT erase any target M3000 system files UNLESS the file name is exactly the same. For example, if you receive a program named SAMPLE and already had a program with the same name, the target file would be copied over by the source file. With this option, the M3000 will prompt you for either RS232 SERIAL or MODEM mode. Once a selection is made, the "Receive Waiting" message will appear. Once transmission has occurred from the source M3000 or computer, a "Complete" message will appear. After the "Complete" message, the M3000 processes each received file. The new files will replace the old ones, and any data files created by replaced programs will be erased.
Receive Select >Clone Receive Select, >Clone allows an M3000 to receive all system files including SETUP menu selections and PROGRAMS, and LOOKUP files from a source M3000 or computer to your target M3000. This option works with Send Select>Clone if you are transmitting from an M3000 to an M3000. The M3000 will prompt you to select either RS232 SERIAL or MODEM as the transmission mode. Once a selection is made, the "Receive Waiting" message will appear. When a transmission has occurred from the source M3000 or computer, a "Complete" message will appear. After the "Complete" message, the M3000 processes each received PROGRAM, SETUP, or LOOKUP file. The name of the file being processed will be displayed. 7-2
Page 97
7Communications NOTE: When Receive Select, >Clone is used, the M3000 will erase all previous SETUP menu selections, PROGRAMS, LOOKUP and data files from the target M3000.
Send Select >Programs Send Select, >Programs functions the same as UPLOAD DATA, except you will be transmitting your M3000 programs instead of data. With this option you have the choice of transmitting ALL PROGRAM FILES or transmitting individual programs. Immediately following the selection of either transmission mode, the M3000 will begin transmission. Programs can be transmitted by RS232 Serial or by Modem.
Send Select >Setup Send Select, >Setup allows you to upload all your M3000 SETUP menu selections. Immediately following the selection of either transmission mode, the M3000 will begin transmission. The SETUP can be transmitted by RS232 SERIAL or MODEM.
Send Select >Lookup Files Send Select, >Lookup Files allows you to upload all your M3000 Lookup files. Immediately following the selection of either transmission mode, the M3000 will begin transmission. Lookup files can be transmitted by RS232 SERIAL or MODEM.
Send Select >Clone Send Select, >Clone actually "clones" an existing M3000. CLONE SEND transmits all M3000 system files including: SETUP menu selections, all PROGRAMS, and LOOKUP files saved in the source M3000 to a target M3000 or computer. You will be prompted for transmission by either RS232 SERIAL or MODEM. Once a selection is made, transmission will begin.
7-3
Page 98
M3000 Portable Bar Code Reader User's Guide
Minimum System Requirements for M3000 Communication Software The M3000 is shipped with a PORTABLE COMMUNICATIONS SOFTWARE DISK. This disk contains three programs and associated files that are used for M3000 communications. These programs include: PCOM SOFTCOM MONITOR
A file transfer program. A memory resident, keyboard emulation program using RS232 serial communications. A communications diagnostics program.
Requirements: Computer
IBM PC, XT, AT, PS/2 and all true compatibles
Operating System
MS DOS 2.1 or higher
System Memory
Computer with at least 256K of memory
Disk Space
PCOM
SOFTCOM
MONITOR
< 120K
< 120K
< 100K
<2K
None
TSR Memory Overhead None
NOTE: Refer to the applicable documentation file supplied with each communications program for installation instructions. For example, the installation instructions for PCOM are located in the PCOM.DOC file.
7-4