Page 11
AT-FS724L Fast Ethernet Switch Installation Guide
Status LEDs Table 2 lists the status LEDs for the AT-FS724L switch. Table 2 Status LEDs LED
Color
Description
POWER
Green
Power is applied to the switch.
OFF
No power is applied to the switch.
Green
A valid link has been established on the port.
Blinking
The port is transmitting data.
OFF
A link has not been detected on the port.
Green
The port is operating at 100 Mbps.
OFF
The port is operating at 10 Mbps.
LNK/ACT
100M
Twisted Pair Ports The AT-FS724L switch has 24 10Base-T/100Base-TX twisted pair ports. Each twisted pair port features a RJ-45 connector. The maximum operating distance for the twisted pair ports is 100 meters (328 feet) when operating at either 10 Mbps or 100 Mbps.
Port Speed The twisted pair ports are compliant with the 10Base-T and 100Base-TX standards and are capable of either 10 Mbps or 100 Mbps operation. Since the ports are IEEE 802.3u Auto-Negotiation compliant, the switch will set the port speed automatically. With Auto-Negotiation, the speed of the ports are set automatically by the switch after it determines the speed of the end-node connected to the port. Auto-Negotiation is designed to ensure that the port on the switch and the end-node are operating at the same speed and that they are communicating at the highest possible common speed between the devices. For example, if an end-node is capable of only 10 Mbps, the switch then sets the port connected to the end-node to 10 Mbps.
3
Page 12
Overview
Duplex Mode Duplex mode refers to the way an end-node sends and receives data on the network. An end-node can operated in either half- or full-duplex mode depending on its capabilities. An end-node that is operating in half-duplex mode can either send data or receive data, but it cannot do both at the same time. An end-node that is operating in full-duplex mode can send and receive data simultaneously. The best network performance is achieved when an endnode can operate at full-duplex, since the end-node is able to send and receive data simultaneously. The twisted pair ports on the AT-FS724L switch can operate in either halfduplex or full-duplex mode and can deliver up to 200 Mbps of bandwidth to the end-nodes. Since these twisted pair ports are IEEE 802.3u-compliant, the duplex mode can be set automatically through Auto-Negotiation. With AutoNegotiation, if the end-node is capable of full-duplex, the port is set automatically to full-duplex mode. If the end-node is capable of half-duplex, the port is set automatically to half-duplex mode. Note In order for the twisted pair port on the AT-FS724L switch to successfully Auto-Negotiate its duplex mode with an end-node, the endnode should also be using Auto-Negotiation. Otherwise, a duplex mode mismatch can occur. The twisted pair port, using Auto-Negotiation, will default to half-duplex if it detects that the end-node is not using AutoNegotiation. This will result in a mismatch if the end-node is operating at a fixed duplex mode of full-duplex.
Auto MDI/MDI-X A twisted pair port on a 10 Mbps or 100 Mbps Ethernet network device can have one of two possible wiring configurations: MDI or MDI-X. A twisted pair port on a PC, router, or bridge is typically wired as MDI, while a twisted pair port on a switch or hubs is usually MDI-X. To connect two 10 Mbps or 100 Mbps network devices together that have dissimilar port wiring configurations, such as an MDI to MDI-X, you would use a straight-through twisted pair cable. To connect two networks devices that have the same wiring configuration, such as MDI to MDI, you would use a crossover cable. The AT-FS724L switch features automatic MDI/MDI-X. The twisted pair port automatically determines the configurations of the port on the device to which it is connected and then configures itself appropriately. For example, if a port on a switch is connected to a port on a bridge, which is typically wired as MDI,
4
Page 13
AT-FS724L Fast Ethernet Switch Installation Guide the port on the switch automatically configures itself as MDI-X. This feature allows you to use either a crossover cable or a straight-through cable when connecting a device to a twisted pair port.
MAC Address Table The heart of an Ethernet switch is the Media Access Control (MAC) address table. Every device that you attach to an Ethernet network has a MAC address. This address is assigned to the device by the device’s manufacturer. For example, each Network Interface Card (NIC) that you install into your network computers has a MAC address that was assigned to it by the card’s manufacturer. A switch’s MAC address table is a list of the MAC addresses of the devices that are connected to its ports. The switch uses this table to direct data frames to their appropriate destination end-nodes, and in some cases, to discard frames that it receives. The switch creates the MAC address table by examining the frames that it receives on its ports. Each frame is examined for its source address; that is, the MAC address of the end-node that sent the frame. The switch checks to determine whether the address is already in its MAC address table. If it is not, the switch adds the address to the table along with the port number on which the frame was received. The result is a table that contains a list of all the MAC addresses of end-nodes that have sent frames to the switch and the ports on the switch to which the end-nodes are connected. The switch also checks the destination MAC address of each frame it receives. The destination address is the MAC address of the end-node to which the frame is intended. If the address is in the table, the switch directs the frame directly to the port where the end-node is located. This helps to ensure that end-nodes will only receive traffic that is intended for them and not have to deal with traffic intended for other end-nodes. If the destination address is not in the MAC address table, the switch broadcasts the frame to all switch ports. When the destination end-node responds, the switch will be able to match the address to a port so that the next time a frame is destined to that particular end-node, the switch will be able to forward the frame to the correct port instead of having to broadcast the frame to all ports. In some cases a switch will even discard a frame. If the switch receives a frame that is destined to an end-node on the same port on which the frame was received, the switch discards the frame. The MAC address table in the AT-FS724L switch can store up to 4,000 MAC addresses. To prevent the table from becoming filled with addresses of endnodes that are no longer active, the switch has a MAC address aging timer.
5
Page 14
Overview
This timer will delete a MAC address from the table if it does not see a frame from the end-node with the address on any port after five minutes (300 seconds). The aging timer also helps to ensure that the table is correct should an end-node be moved from one port on the switch to another port.
Store and Forward These Fast Ethernet Switches use store and forward as the method for receiving and transmitting frames. When an Ethernet frame is received on a switch port, the switch does not retransmit the frame out the destination port until it has received the entire frame and stored the frame in a port buffer. It then examines the frame to determine if it is a valid frame. Invalid frames, such as fragments or runts, are discarded by the switch. This insures that only valid frames are transmitted out the switch ports and that damaged frames are not propagated on your network.
Backpressure and Flow Control In order to maintain the orderly movement of data between the end-nodes, an Ethernet switch may periodically need to signal an end-node to stop sending data. This can occur under several circumstances. For example, if two endnodes are operating at different speeds, the switch, while transferring data between the end-nodes, might need to instruct the faster end-node to stop transmitting data to allow the slower end-node to catch up. An example of this would be when a server operating at 100 Mbps is sending data to a workstation operating at only 10 Mbps. How a switch signals an end-node to stop transmitting data differs depending on the speed and duplex mode of the end-node and switch port. A twisted pair port operating at 100 Mbps port and half-duplex mode stops an end-node from transmitting data by forcing a collision. A collision on an Ethernet network occurs when two end-nodes attempt to transmit data using the same data link at the same time. A collision causes end-nodes to stop sending data. When the switch needs to stop a 100 Mbps, half-duplex end-node from transmitting data, it forces a collision on the data link, which stops the end-node. Once the switch is ready to receive data again, the switch stops forcing collisions. This is referred to as backpressure. A port operating at 100 Mbps and full-duplex mode uses PAUSE frames, as specified in the IEEE 802.3x standard, to stop the transmission of data from an end-node. Whenever the switch wants an end-node to stop transmitting data, it issues this frame. The frame instructs the end-node to cease transmission. The switch continues to issue PAUSE frames until it is ready again to receive data from the end-node. This is referred to as flow control.
6
Page 15
AT-FS724L Fast Ethernet Switch Installation Guide
Internal Power Supply The AT-FS724L uses a universal internal switching power supply operating at 100-120/200-240V AC. The frequencies are 50/60 Hz, 0.5A at all input voltage +/-3%. Allied Telesyn ships power cords with these units to the U.S., Continental Europe, and the U.K. The switches require input of 100-120 or 200-240V AC. The AT-FS724L switch has a maximum power consumption of 15W.
7
Page 16
Overview
Network Topologies The AT-FS724L switch can be used in a variety of network topologies, such as a power workgroup or cascade. Both topologies are described below.
Power Workgroup Topology A power workgroup topology, shown in Figure 2, allows each end-node to directly connect to a 10/100Base-TX port on an AT-FS724L switch. This gives each end-node a dedicated 10 Mbps or 100 Mbps link. Workstations
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
AT-FS724L
24 Port Fast Ethernet Switch 1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
AUTO MDI/MDI-X
100M LNK/ACT 100M POWER
LNK/ACT
Workstations 10 Mbps 100 Mbps
Figure 2 Power Workgroup Topology
8
Server
Page 17
AT-FS724L Fast Ethernet Switch Installation Guide
Cascade Topology Connecting two similar networking devices together is called ‘cascading’. Figure 3 illustrates this topology where Port 24 on the AT-FS724L switch is connected to Port 8 on the AT-FS716 switch. Since Port 24 is wired as auto MDI/MDI-X, a crossover or straight-through Category 5 or better twisted pair cable can be used. Workstations
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
AT-FS724L
24 Port Fast Ethernet Switch 1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
AUTO MDI / MDI-X
100M LNK/ACT 100M POWER
LNK/ACT
AT-FS724L 100 m (328 ft)
AT-FS716
Workstations
Server
10 Mbps 100 Mbps
Figure 3 Cascade Topology
9
Page 18
Page 19
Chapter 2
Installation
Verifying the Package Contents Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
❑
One AT-FS724L Fast Ethernet Switch
❑
Four protective feet (for desktop use only)
❑
This installation guide
❑
Warranty card
❑
An AC power cord
❑
Rackmounting kit
11
Page 20
Installation
Planning the Installation Be sure to observe the following guidelines when planning the installation of your switch.
❑
The end-nodes connected to the twisted pair port can operated at either 10 Mbps or 100 Mbps and half- or full-duplex mode.
❑
The end-node connected to a port on the switch can be a network adapter card, repeater, router, hub, or another switch.
❑
Refer to Table 3 for the cabling specifications for the twisted pair ports. Table 3 10/100Base-TX Twisted Pair Port Cabling Specifications
Operating Mode
Twisted Pair Cable
Maximum Operating Distance
10Base-T
Shielded or unshielded Category 3 or better
100 m (328 ft)
100Base-TX
Shielded or unshielded Category 5 or better
100 m (328 ft)
Selecting a Site Be sure to observe the following guidelines when selecting a site for your switch.
12
❑
Select a site that is dust-free and moisture-free.
❑
Select a site that will allow you to easily access the switch’s power and data cables.
❑
The twisted pair port cabling must be kept away from sources of electrical noise, such as radios, transmitters, power lines, broadband amplifiers electrical motors, and fluorescent fixtures.
❑
Make sure the air flow around the switch and through its vents on the side and back are not restricted.
❑
Use dedicated power circuits or power conditioners to supply reliable power to the switch.