Page 62

Chapter

5

Downloading Configurations Chapter Objectives

This chapter describes how to download a configuration between the Reader and a personal computer running the AdaptaScan software. Section

Connecting a Personal Computer

Page

Connecting a Personal Computer

5–1

Downloading Firmware

5–3

Downloading a Configuration

5–4

AdaptaScan Bar Code Reader configurations and firmware are downloaded:

• directly through the Configuration Port Connector on the Reader • through any Reader on the same DeviceNet or RS-485 network Remove the protective cap from the Reader’s Configuration Port Connector. Use the Configuration Cable (Catalog No. 2755-NC48) to connect the computer to a Reader. One cable end connects to the Configuration Port Connector on the Reader. Connect the end with the 9-pin D shell connector to the computer’s serial port. You may need a 9-to-25 pin adapter if your computer has a 25-pin serial port. Note: The Series A Reader uses the 2755-NC43 programming cable. This cable is not compatible with the Series B Reader.

!

ATTENTION: Do not extend the length of the Configuration Cable (Catalog 2755-NC48). This unshielded cable cannot exceed a length of 3 meters or 9 feet, 10 inches.

Note: Configure the computer port and address for download using Preferences dialog in the AdaptaScan Software.

Page 63

5–2

Downloading Configurations

The following figure shows the connections for downloading firmware or a Reader configuration.

Configuration Cable (Catalog No. 2755-NC48)

9 to 25 Pin Adapter may be required

9 Pin Male D Connector 4 Pin Female Circular Connector

Personal Computer

Configuration Port Connector (Has a protective cap)

Note: The Series A Reader uses the 2755-NC43 programming cable. This cable is not compatible with the Series B Reader shown above.

!

ATTENTION: After downloading, replace the protective cap on the Configuration Port Connector to prevent the collection of dirt and moisture in the connector.

Page 64

Downloading Configurations

Downloading Firmware

5–3

This section shows the procedure used to download new firmware to the AdaptaScan Bar Code Reader. Each Reader is shipped with factory default firmware. The software will prompt you if you need to download new firmware. Verify that your computer is connected to a Reader as shown on previous page. To download new firmware to a Reader: 1. Run the AdaptaScan software (Catalog No. 2755-ASN). 2. From the Project menu, choose Open or New.

Highlight Project

3. Select and open the project. If creating a new project, add a Bar Code Reader by clicking the New button on the project dialog. Verify that the DeviceNet address matches the address currently used by the Reader. If downloading firmware to a new Reader, check that the DeviceNet address is set to 63 in the Device dialog. 4. From the Project dialog, click the Firmware button. The File Open dialog appears.

Select .ini Firmware File (aaaa is version number)

Snexaaaa.ini

5. Select the firmware file (shows revision number) to download and click the OK button. The following message appears as the firmware is downloaded. Download will take several minutes. During this time, the Module LED will flash red. Resetting. Please Wait . . . Sending. Please Wait . . .

6. The message disappears when the download is complete.

Page 65

5–4

Downloading Configurations

Downloading a Configuration

This section shows how to download a configuration to one or more Readers. Verify that your computer is connected to a Reader as shown on previous page. To download a configuration to a Reader: 1. Run the AdaptaScan software (Catalog No. 2755-ASN). 2. From the Project menu, choose Open. The Project Open dialog appears.

Highlight Project

3. Select and open the project containing the configuration you want to download. 4. Verify that each device within the project has a unique DeviceNet address (even if you are not using DeviceNet communications). With the Reader name highlighted, click the Device button to open the Device dialog and set the address.

Set to Unique Address

5. From the Project dialog, select the Reader or Readers to which you want to download a configuration. To select multiple Readers, hold down the [Ctrl] button while making the selections. 6. Click the Send Device button to download to a selected Reader or the Send All button to download to all Readers on the network. The following message appears during the download. Resetting.

Please Wait . . .

Sending.

Please Wait . . .

When the download is complete, this message disappears.