Page 59

Chapter

4

Installing / Removing the Reader Chapter Objectives

This chapter describes how to install the Reader on the wiring base. Section

Installation

Page

Installation

4–1

Power-up Sequence

4–2

Checking Reader Operation

4–2

Replacing a Reader

4–3

The Reader plugs into the connector on the wiring base. Install the Reader with or without the power disconnected from the wiring base. To install the Reader:

Captive Screws 4 Locations Tighten to 18 inch-pounds (2.0 NSm)

Wiring Base Insulating Cover

1. Make sure the insulating cover with warning label attached is in position, so the flap covers the field wiring connections inside the wiring base. 2. Place the Reader over the wiring base and carefully align the connector on the bottom of the Reader with the connector on the wiring base (to avoid bending pins). 3. Press Reader down firmly until it contacts the wiring base. 4. Secure the Reader with four screws. Alternately tighten screws to a torque of 18 inch-pounds (2.0 NSm).

Page 60

4–2

Installing / Removing the Reader

Power-up Sequence

On initial power-up, the Reader performs a series of self-diagnostic tests and LED tests (all LEDs flash). When the Module LED flashes and turns a steady green the power-up sequence is complete. The complete power-up sequence takes a few seconds.

Checking Reader Operation

The Reader is shipped from the factory with these defaults:

• All symbologies enabled (except Pharma Code). • Laser Light set to Always On in Scanner dialog. If the initial Reader configuration has been changed, you must enable the Code 39 symbology and the other parameters above. (Refer to the AdaptaScan Software user manual.)

To quickly check the operation of a Reader with factory defaults: 1. Apply power to the Reader. 2. Position the above Code 39 test symbol approximately 12 inches (.3 meter) from the Reader. Skew the page slightly.

Scan page slightly skewed.

3. The scan beam should be scanning continuously. 4. Observe the Symbol LED. The Symbol LED illuminates when the Reader is scanning the bar code symbol.

Page 61

Installing / Removing the Reader

Replacing a Reader

4–3

To replace a Reader: Note: If you are installing more than one Reader on a network, install each Reader one at time and change the DeviceNet address before installing the next Reader. 1. Loosen the 4 screws that secure the Reader to the wiring base.

Loosen the 4 captive screws.

2. Pull the Reader straight up from the wiring base. When replacing a Reader, it is not necessary to disconnect the power. 3. Install the Reader by aligning the connector on the Reader with the connector on the wiring base and pressing the the Reader down firmly. 4. Tighten the four screws that secure the Reader to the wiring base to 18 inch-pounds (2.0 NSm). 5. Set a (unique) DeviceNet address for the Reader using the Device dialog of the AdaptaScan Software. The initial default address for a firmware download is 63. Note: When downloading updated firmware to a Reader with existing firmware, you must set the DeviceNet address to the address used by the Reader. 6. Download firmware to the Reader. 7. Download the Reader configuration to the Reader directly through the Configuration Port Connector or from any other Reader on the network.