Page 52

Installing the Wiring Base and Power Supply

RS-485 and RS-422 Connections

3–17

The wiring base has an RS-485/RS-422 terminal block for point-to-point or network communications. Up to 32 devices can be installed on a single DH485 network. Important: The DH485 network cable requires proper shielding, grounding, and termination. Refer to Data Highway / Data Highway Plus / Data Highway DH485 Cable Installation Manual (Publication No. 1770-6.2.2).

Network or Point-to-Point Allen-Bradley offers a variety of devices that support RS-485 or RS-422 communications. One of the more common RS-485 network types is an SLC DH485 network. SLC 5/04

Reader

Reader

DH485

DH485

Link Coupler

Use the link coupler (Catalog No. 1747-AIC) when the distance between the Reader and SLC is greater than 50 feet (15.2 meters). The Reader can connect directly to another RS-485/RS-422 device. The connections for both network and point-to-point are the same. RS-485/422 TxA RS-485/422 TxB RS-422 RxA

Line Termination

RS-422 RxB Ground Shield

Line Termination The end devices on an RS-422/RS-485 network must be terminated. A termination switch is provided. Only the end devices, on each end of a network, should be terminated.

Page 53

3–18

Installing the Wiring Base and Power Supply

RS-232 Connections

The RS-232 port provides point-to-point communications at distances up to 50 feet (15.2 meters). Use the RS-232 port for a direct connection to a controller, personal computer, or other device that supports one of the protocols (terminal, Allen-Bradley DF1, Allen-Bradley DH485).

Reader

RS-232 connections are made to the RS-232 port terminal block. Transmit (Tx) Ground (GND) Receive (Rx) Clear to Send (CTS) Ready to Send (RTS) Shield (SHD)

Page 54

Installing the Wiring Base and Power Supply

I/O Modules and Wiring

3–19

The wiring base supports 2 optional input or output modules. Any of these modules can be used. These modules function like switches, they do not supply a voltage. Refer to Appendix A for specifications.

!

ATTENTION: The wiring base contains hazardous voltages which can cause shock, burns or death. Disconnect and lockout all power sources before servicing. Verify power with meter.

Description

Catalog No.

DC Output Module – rated at 3 to 60 VDC.

2755-OB5S

AC Output Module – rated at 12 to 140 VAC.

2755-OA5S

AC Output Module – rated at 24 to 280 VAC.

2755-OM5S

DC Input Module – accepts 3.3 to 32 VDC.

2755-IB5S

AC/DC Input Module – accepts 90 to 140 VRMS or VDC

2755-IA5S

AC/DC Input Module – accepts 180 to 280 VRMS or VDC

2755-IM5S

All of the I/O modules plug into the wiring base and are secured by a screw through the module. Mounting Screw

Connect the I/O wiring to the two I/O terminal blocks. When using DC modules, observe the polarity of the connections (shown on circuit board or label on wiring base insulating cover). I/O Connectors

Earth Ground

I/O Modules Wiring Base

Page 55

3–20

Installing the Wiring Base and Power Supply

Output Module Application Shown below is a typical output module application. When connecting high impedance loads, you may need to add a resistor in parallel with the load. This resistor (typically 300 to 6,000 ohms) provides a continuous minimum current flow (10 mA DC or 50 mA AC) through the output module in the closed state. See Appendix C for available Allen-Bradley fuse, diode and resistor terminal blocks. Fuse Recommended

Load

Optional Resistor

+ – AC or DC Source

Back Electromotive Force (EMF) is sometimes generated when an inductive load is switched off. Back EMF may damage the output module. A diode in parallel with the inductive device dissipates the back EMF. Fuse Recommended

Inductive Load

Optional Diode

+ – DC Source

Page 56

Installing the Wiring Base and Power Supply

3–21

Input Module Application External Power Source A typical input module application using external power source: External Input Contacts

Fuse Recommended

–

+

AC or DC Source

The module and the switch receive power from an external AC or DC source. Although input modules may be used for package detection, use the package detect input (see next page) whenever possible. See Appendix B for available Allen-Bradley fuse, diode and resistor terminal blocks. Internal Power Source A typical input module application using the package detect +12V internal power source and Catalog No. 2755-IB5S input module: External Input Contacts

To + To -

To +12V To GND

The module and the switch receive power from the package detect +12V source. Only use input module Catalog No. 2755-IB5S for this application. Important: Package detect terminals are not powered until a Reader is installed on the wiring base. Note: The circuit must not draw more than 50mA from the Package Detect terminal block.

Page 57

3–22

Installing the Wiring Base and Power Supply

Package Detector

The package detect input accepts only a current sinking output. Allen-Bradley Photoswitchr package detectors are recommended. Select a switch from the PhotoSeries 6000 or 9000 product line that best suits your application. Make sure you order a sinking (12V DC) type sensor. Mounting brackets and cables are also available. Important: Package detect terminals are not powered until a Reader is installed on the wiring base. The package detector must be able to operate using the +12V DC source (12V) and not draw more than 100mA. The package detect sense line (TRG) must be able to sink 5mA at +12V DC. Follow these guidelines when installing a package detector.

• Mount the package detector and reflector so that the scan beam does not strike either of them.

• Install the reflector within the operating range of the package detector.

• The package detector beam must be broken before the label is in position for scanning. The package detect should remain active while the symbol is being scanned.

• Grounding the trigger (on Package Detect terminals in wiring base) activates the package detect (scanner).

Page 58

Installing the Wiring Base and Power Supply

3–23

The following is a typical package detector configuration:

Reflector

Package Detector

Connect the package detect wiring to the wiring base as shown. Note: If you are using a sensor with mechanical contacts, refer to page 3–21 for wiring connections to an input module. Package Detector

PKG DET +12VDC Ground Trigger Shield