Page 44
Installing the Wiring Base and Power Supply
3–9
Top Post Mounting The mounting plate attaches to the bottom of the wiring base with three screws (see next page). The mounting bracket post is threaded into the hole at the center of the mounting plate. Lock the mounting post in position by tightening the locking knob. For additional security, you can remove the locking knob and replace it with the hex bolt provided. The two hex socket screws are not used in this configuration.
Wiring Base Mounting Plate
Mounting Post Screws Into Mounting Plate
Mounting Plate to Reader Screws (Hardware Provided with Base) See Side Mounting Illustration Next Page 3 Mounting Holes
Bracket Locking Knob or Bolt (5/16 x 1 inch) Adjustable Mounting Bracket
Page 45
3–10
Installing the Wiring Base and Power Supply
Side Post Mounting The mounting plate attaches to the bottom of the wiring base with three screws that are provided with the base. The mounting bracket post (flat side) attaches to the mounting plate with two hex socket screws. Five sets of 2 holes allow the bracket post to attach to the front, back or either side of the mounting plate. Lock the mounting post in position by tightening the locking knob. For additional security, you can remove the locking knob and replace it with the hex bolt provided.
Mounting Plate
Mounting Plate to Reader Screws Screws Provided Catalog No. (3) #10-32 x 1/2 Inch 2755-NB40 (3) M5 -.8 x 16mm 2755-NB41 Mounting Post to Mounting Plate Screws (1/4 – 20 x .5 Hex Socket) Use 3/16 inch Hex Wrench
Bracket Locking Knob or Bolt (5/16 x 1 inch) Adjustable Mounting Bracket
3 Mounting Holes (9 /32 inch diameter)
Page 46
Installing the Wiring Base and Power Supply
3–11
Installing the Safety Wire Install the safety wire whenever the mounting bracket is installed in an inverted position. The safety wire prevents the Reader from dropping to the floor when the bracket locking knob is loosened.
Attaches to Mounting Plate Screw Safety Wire Clamping Nut
Loosen Locking Knob to Remove Clamping Nut
Place one end of the safety wire under a mounting bracket clamping nut. With the bracket locking knob loosened, the clamping nut can be removed by hand. The other end of the safety wire is attached to the Reader using one of the screws that secure the mounting plate to Reader wiring base.
Page 47
3–12
Installing the Wiring Base and Power Supply
Power Requirements
The Reader requires 14 watts (maximum) of power. The Reader accepts 11 to 28 VDC at either one of the two DeviceNet terminal blocks (terminals 1 & 5), even if DeviceNet is not used. 11-28 VDC+
11-28 VDC+
V-
V-
From Power Supply Connect to Earth Ground
Reverse Polarity Indicator
The reverse polarity LED (top illustration) is Green when power is properly connected. If this LED is Red, the power + and – connections are reversed. You must correct a reverse polarity condition before installing the Reader.
Power Supplies
Two power supplies are available for the AdaptaScan Reader.
• 120 VAC Power Supply (Catalog No. 2755-PW46 ) plugs directly into a standard wall electrical socket.
• 240 VAC Power Supply (Catalog No. 2755-PW47 ) supplied with an IEC 320 unterminated power cord. Use one of these power supplies or another 11 to 28 VDC power source when power is not provided by another device on a DeviceNet network.
!
ATTENTION: Permanent damage to the Reader can be caused by: • Connecting the power supply to more than one Reader. • Connecting power supplies in parallel. • Shorting out the power supply.
Page 48
Installing the Wiring Base and Power Supply
3–13
Catalog No. 2755-PW46 Power Supply The 120 VAC Power Supply (Catalog No. 2755-PW46) provides power to one AdaptaScan Bar Code Reader. It is not rated for industrial environments and must be mounted in a clean, dry location or a suitable enclosure. Connections to the power supply are made at the 3 screw terminals. 2.75 Inches (70mm)
3.25 Inches (83 mm)
+
–
Catalog No. 2755-PW47 Power Supply The 240 VAC power supply (Catalog No. 2755-PW47) provides power to one Reader. Included is a standard IEC 320 unterminated power cord. The PW47 supply is not rated for industrial environments and sets on a flat surface. Connections to the power supply are made at the 3 screw terminals. 5.25 Inches (133)
3 Inches (76 mm)
1
2
3
+ GND –
Page 49
3–14
Installing the Wiring Base and Power Supply
Power Connections
Single Reader Power Connection Below is a single power supply (Catalog No. 2755-PW46, -PW47) providing power to a single Reader. Do not connect other DeviceNet power supplies to the 2755-PW46 or -PW47 supply. Use a shielded cable (Belden 9316 recommended) when making power connections. Note: You must ground V- to Earth Ground at a single point, preferably as near the power supply as possible.
24V+
V-
Reader Ground Screw on Wiring Base
Multiple Reader Connections using 2755-PW46/-PW47 Supply In the following illustration, each Reader is powered by a separate Catalog No. 2755-PW46 or -PW47 power supply. The Catalog No. 2755-PW46 is shown. Do not connect power supplies in parallel. Use a shielded cable (Belden 9316 recommended) when making power connections. Note: You must ground V- to Earth Ground at a single point on the power supply link, preferably as near the power supply as possible. Ensure that the V+ lines are not connected together and that the V– lines are connected together as shown on top of next page.
Page 50
Installing the Wiring Base and Power Supply
Reader 2
Reader 1
3–15
Reader 3
Other DeviceNet Devices Ground V- at One Place
V-
24V+
VGround Screw on Wiring Base
24V+
VGround Screw on Wiring Base
24V+ Ground Screw on Wiring Base
Ground Screw on Wiring Base
See DeviceNet Cable System Planning and Installation Manual (Publication No. DN-6.7.1) for recommendations and accessories.
Multiple Reader Connections using Other Power Supply Below all Readers are powered by another power supply. Use a linear unregulated power supply. The supply must provide 14 watts of power to each reader. Use a shielded cable (Belden 9316 recommended) when making power connections. Note: You must ground V- to Earth Ground at a single point on the power supply link, preferably as near the power supply as possible. V+ User Specified Unregulated Ground Linear Power Screw Supply
Other DeviceNet Devices
VGround V- at One Place
Reader 1
Reader 2
Reader 3
See DeviceNet Cable System Planning and Installation Manual (Publication No. DN-6.7.1) for recommendations and cable accessories.
Page 51
3–16
Installing the Wiring Base and Power Supply
DeviceNet Connections
For network wiring, the wiring base has two DeviceNet terminal blocks; one for incoming power and communications, the other for outgoing power and communications. DeviceNet communications requires 3 wires (2 communications, 1 ground) and a shield. You can install the Reader in a single or multiple drop configuration. Up to 63 slave devices can be installed on a single DeviceNet master/slave network. Up to 32 Readers can be installed on a DeviceNet peer-to-peer network.
Reader
Reader
Reader
Other Devices
Both DeviceNet terminal blocks are tied to each other. You can connect the wiring to either terminal block. Use cabling (Catalog No. 1485C-P1A50, -P1A150 or -P1A300) for all DeviceNet connections.
V+ Can_H Shield Can_L V-
V+ Can_H Shield Can_L V-
Line Termination
See DeviceNet Cable System Planning and Installation Manual (Publication No. 1485-6.7.1) for recommendations and cable accessories.
Line Termination The two devices furthest apart from each other on a DeviceNet network must be terminated. A termination switch is provided. Only the devices at the ends of the network can be terminated.