Page 36

Chapter

3

Installing the Wiring Base and Power Supply Chapter Objectives

General Mounting Guidelines

This chapter describes how to install and mount the wiring base. Section

Page

General Mounting Guidelines

3–1

Dimensions and Clearances

3–2

Mounting the Wiring Base

3–4

Conduit and Cable Connections

3–6

Mounting Bracket

3–8

Power Requirements

3–12

Power Supplies

3–12

Power Connections

3–14

DeviceNet Connections

3–16

RS-485/RS-422 Connections

3–17

RS-232 Connections

3–18

I/O Modules and Wiring

3–19

Package Detector

3–22

Before mounting the wiring base, determine the proper orientation and position as described in Chapter 2.

• Leave adequate clearances for wiring. • The wiring base has four conduit openings. Seal unused conduit openings with the 3 hole plugs provided with wiring base. Use cord grips with rubber grommets on cables that enter wiring base. Two different size grommets are provided with each cord grip.

• Route wires carefully to reduce or minimize electrical noise. When communication and power wiring must cross, make their intersection perpendicular.

• Proper grounding of the wiring base limits the effects of noise due to Electromagnetic Interference (EMI). The wiring base has a ground screw for connecting cable shields and ground wires. To avoid EMI problems, all cables must be shielded and grounded at one end. Grounding is also an important safety measure.

Connect to Earth Ground

Wiring Base

Page 37

3–2

Installing the Wiring Base and Power Supply

Dimensions and Clearances

Make sure there is adequate space around the Reader for:

• Mounting and removing the Reader • Wiring base connections • Configuration cable Reader Front View

Midpoint Scan Line

3.57 Inches (91 mm) 7.14 Inches (182 mm)

Side View

Back View

4.26 Inches (108 mm) 3.91 Inches (99 mm)

3.95 Inches (100 mm)

.35 Inches (9 mm)

Page 38

Installing the Wiring Base and Power Supply

3–3

Wiring Base The wiring base is available in two versions:

• U.S. Version (Catalog No. 2755-NB40) • Metric Version (Catalog No. 2755-NB41) The dimensions are identical for both versions. Differences are in the thread sizes of the conduit holes and the bottom mounting holes. 3.87 Inches (98 mm)

5.36 Inches (137 mm)

1.67 Inches (42 mm)

1.67 Inches (42 mm)

Front View

End View 5.36 Inches (137 mm)

3.87 Inches (98 mm)

Bottom View

Reader / Base Assembly

Scan Line at Raster Angle 5.82 Inches (148 mm)

3.65 Inches (91 mm)

Front View

Side View Read Range Measured From This Point

Page 39

3–4

Mounting the Wiring Base

Installing the Wiring Base and Power Supply

There are 2 options for mounting the wiring base (Catalog No. 2755-NB40 or -NB41):

• Top Mounting – Mount the base using 3 screws through the top mounting holes.

• Bottom Mounting – Mount the base using 3 screws through the mounting surface into threaded holes on bottom of wiring base.

Top Mounting The wiring base mounts from the top to any flat surface with three #10 or M5 mounting screws. The screw heads must be less than 3/8 inch in diameter allowing them to fit inside the mounting hole. The length of the mounting screws must be 1/2 inch (12.5 mm) plus the depth the screw penetrates the mounting surface. Note: The 3 screws provided with the wiring base are suitable for use with the mounting bracket (Catalog No. 2755-NM42).

ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ Î ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ

A full size mounting template is provided with the wiring base. Use the following diagram for reference. Top Mounting Holes 4.46 Inches (113 mm)

3 Holes Scan Beam

2.79 Inches (71 mm)

2.65 Inches (67 mm)

Page 40

Installing the Wiring Base and Power Supply

3–5

Bottom Mounting The wiring base mounts from the bottom to any flat surface with three mounting screws. The holes on the U.S. version have #10-32 UNF-2B threads. The holes on the metric version have M5 x .8 threads. The length of the screws must not be greater than 1/2 inch (12.5 mm) plus the thickness of the mounting surface. Wiring Base Has Three Threaded Mountng Holes

ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ

A full size mounting template is provided with the wiring base. Use the following diagram for reference. 4.46 Inches (113 mm)

Scan Beam 2.79 Inches (71 mm)

ÁÁ

ÁÁ

3 Holes .6 inch (15 mm) deep Thread Size of Holes U.S. Metric

#10-32 UNF-2B M5 x .8

2.65 Inches (67 mm)

Wiring Base Dust Cover To prevent debris from entering the wiring base when a Reader is not installed, slip the dust cover over the base. The dust cover is held in place by the stretch fit over the wiring base.

!

ATTENTION: The wiring base dust cover is not for permanent installation. The dust cover temporarily protects the wiring base until the Reader is installed.

Page 41

3–6

Installing the Wiring Base and Power Supply

Conduit and Cable Connections

All permanent Reader connections are made to the wiring base. Wiring connections are made with conduit or cables. The conduit openings in the wiring base are different for the U.S. and metric versions. The U.S. version (Catalog No. 2755-NB40) has 1/2-14 NPSC threads, the metric version (Catalog No. 2755-NB41) has PG13.5-18 threads. See the chart below for recommended wire and cable types. Connection

Recommended

Power ➀ I/O

Shielded Belden 9316 Depends upon module rating. Refer to Appendix A

RS-485

Use Belden 9842

RS-422

Use Belden 9830

RS-232

Use Belden 8303 or Alpha 45123

DeviceNet

Use Allen-Bradley Catalog No. 1485C-P1A50, -P1A150 or -P1A300 (50, 150 or 300 meter cable)

Package Detect

#22 AWG minimum

➀ DeviceNet cable contains wiring for power connections

Cabling Where the cable enters the wiring base, use the supplied cord grips with rubber grommets. Each cord grip comes with 2 different size grommets.

• Cord grips with small diameter grommet accommodate wire diameters 0.191 to 0.354 inches (4.9 to 9.0 mm).

• Cord grips with large diameter grommet accommodates wire diameters 0.236 to 0.472 inches (6.0 to 12.0 mm). You can obtain additional cord grips from most electrical supply outlets. Make sure you use Teflon tape or other type of thread sealant to maintain a NEMA Type 4 rating.

Cord Grip Threaded Bushing Grommet Nut Cable Hole Plug (Metric ) Hole Plug (U.S. )

Page 42

Installing the Wiring Base and Power Supply

3–7

Conduit Use flexible conduit whenever possible. This allows you to adjust the position of the Reader (when mounting bracket is used).

Conduit Fitting User Supplied

Conduit

Hole Plug (Metric ) Hole Plug (U.S. ) Wires

Hole Plugs Three hole plugs are supplied with the wiring base. Use these plugs on unused conduit openings to maintain the NEMA Type 4 rating. U.S. Wiring Base (Catalog No. 2755-NB40) The conduit opening for the U.S. wiring base uses a NPSC threaded plug. Use Teflon tape or other thread sealant when inserting the hole plug in the conduit opening to maintain a NEMA Type 4 seal. Tighten hole plug with a 3/8” hex wrench. Metric Wiring Base (Catalog No. 2755-NB41) The conduit opening for the metric version requires an O-ring with the hole plug. Place the O-ring on the hole plug, then insert the hole plug in the conduit opening and tighten with a flat blade screwdriver.

Page 43

3–8

Installing the Wiring Base and Power Supply

Mounting Bracket

The mounting bracket kit (Catalog No. 2755-NM42) is suitable for a variety of applications. This bracket allows you to mount the Reader at just about any angle or degree of rotation.

Kit Contents The mounting bracket kit contains:

• • • • •

Adjustable mounting bracket Mounting plate Safety wire Two hex socket screws Hex bolt

!

ATTENTION: Install the safety wire when the bracket is mounted in an inverted position. If the bracket is mounted inverted and the locking knob is loosened, the Reader could release from the bracket and cause personal injury or damage to the Reader.

Installing the Mounting Bracket The mounting bracket is attached to a mounting surface using three screws (1/4 inch or M6).

ÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉ Mounting Surface

The mounting holes for the bracket consist of 3 holes spaced apart on a 4 5/16 inch (109.54 mm) diameter pattern. 4-5/16 inch (109.54 mm) Diameter Bolt Pattern

3 Bolt Holes Apart