The text of a manual · part 4 of 15
AdaptaScan Bar Code Readers User Manual (Cat. No. 2755-SN3, -SN5, -SN8): 2 - Installation Considerations
Pages 27 to 35 of 96, from AdaptaScan Bar Code Readers User Manual (Cat. No. 2755-SN3, -SN5, -SN8)
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 27
Chapter
2
Installation Considerations Chapter Objectives
This chapter describes important factors that affect how the AdaptaScan Bar Code Reader is oriented in respect to package or component labels. Section
Orientation Factors
Page
Orientation Factors
2–1
Reader Scan Beam
2–1
Picket Fence or Step Ladder Orientation
2–2
Skew, Pitch, and Tilt
2–3
Usable Beam Width
2–4
Apparent Element Width
2–6
Reader Adjustments
2–7
Read Ranges
2–8
Calculating Scans per Label
2–9
The mounting of the Reader for optimum performance depends on these factors.
• Read range • Type of scanning • Skew angle
Reader Scan Beam
The scan beam exits the scan window parallel to the base.
Scan Beam Exits Parallel to Base
Page 28
2–2
Installation Considerations
Picket Fence or Step Ladder Orientation
The Reader supports raster and linear scanning. The Reader can be mounted in either a step ladder or picket fence orientation with respect to the bar code label. The type of scanning and the placement of the bar code label usually determines the orientation.
Picket Fence Orientation
Reader Mounted On Side of Conveyor
Step Ladder Orientation
Reader Mounted On Side of Conveyor
Reader Mounted Above Conveyor Reader Mounted Above Conveyor
If a linear scanning Reader is aligned parallel with the long axis of a picket fence label, the same strip of label is scanned repeatedly. Because of this, picket fence applications usually use a raster scan.
When the labels pass the Reader in a step ladder orientation, a linear scan is preferred. The beam scans the label as it passes. The number of scans per label depends upon the label size, scan rate and the conveyor speed.
Page 29
Installation Considerations
Skew, Pitch and Tilt
2–3
The skew, pitch and tilt of a bar code symbol affect its readability. Symbols that are pitched or skewed up to are still readable. Although some skew is needed (see below), it should not exceed Symbols may be tilted if the scan beam passes through all bars. Skewed Symbol Pitched Symbol Tilted Symbol
No Tilt, Pitch, or Skew
Mount the Reader so that the scan beam is nearly perpendicular to the bars of the symbol and crosses every element and quite zone. With raster scanning, the scan beam should cover the entire area where a label is expected.
Scan Beam
Quiet Zone
Recommended Skew Angle
Quiet Zone
Quiet Zone
Quiet Zone
For optimum performance, mount the Reader so it scans the symbol from a skewed position 20 to from perpendicular to the symbol.
Top Of Package
Skew Angle
Side Of Package
Skew Angle
= Optimum Reader Mounting Angle
= Optimum Reader Mounting Angle
Page 30
2–4
Installation Considerations
Usable Beam Width
The usable beam width depends on the Reader type, the scan angle and the distance from the bar code symbol. Make sure that the scan beam is wide enough for the area you are scanning. Increasing the scan angle setting (using configuration software) or moving the Reader away from the symbol increases the beam width. The usable beam width is approximately 80% of the total beam width. The end 10% on either side of the scan beam cannot decode bar code symbols. Usable Beam Width Total Beam Width
The following charts show the usable beam width for the default scan angle settings. We recommend that you use the default setting to determine the position of the Reader. This allows you to increase or decrease the scan angle after installation.
Maximum Usable Beam Width (Catalog No. 2755-SN3) ➀ At This Distance: 70 inches (1.78 meter) 65 inches (1.65 meter)
Usable Beam Width Is: 77.6 inches (1.97 meter) 72.1 inches (1.83 meter)
60 inches (1.52 meter) 55 inches (1.40 meter)
66.5 inches (1.69 meter) 61.0 inches (1.55 meter)
50 inches (1.27 meter) 45 inches (1.14 meter) 40 inches (1.02 meter) 35 inches (.89 meter) 30 inches (.76 meter) 25 inches (.64 meter) 20 inches (.51 meter) 15 inches (.38 meter) 10 inches (.25 meter)
55.4 inches (1.41 meter) 49.9 inches (1.27 meter) 44.3 inches (1.12 meter) 38.8 inches (.98 meter) 33.2 inches (.84 meter) 27.7 inches (.70 meter) 22.2 inches (.56 meter) 16.6 inches (.42 meter) 11.1 inches (.28 meter) Scan Angle = = Default
➀ Contact your Allen-Bradley representative for availability.
Page 31
Installation Considerations
Maximum Usable Beam Width (Catalog No. 2755-SN5) At This Distance:
Usable Beam Width Is: 51.0 inches (1.30 meter) 47.3 inches (1.20 meter)
70 inches (1.78 meter) 65 inches (1.65 meter) 60 inches (1.52 meter)
43.7 inches (1.11 meter)
55 inches (1.40 meter)
40.0 inches (1.02 meter)
50 inches (1.27 meter)
36.4 inches (.92 meter)
45 inches (1.14 meter)
32.8 inches (.83 meter)
40 inches (1.02 meter)
29.1 inches (.74 meter)
35 inches (.89 meter)
25.5 inches (.65 meter)
30 inches (.76 meter) 25 inches (.64 meter)
21.8 inches (.55 meter) 18.2 inches (.46 meter)
20 inches (.51 meter)
14.6 inches (.37 meter)
15 inches (.38 meter)
10.9 inches (.28 meter)
10 inches (.25 meter)
7.3 inches (.18 meter) Scan Angle = = Default
Maximum Usable Beam Width (Catalog No. 2755-SN8) At This Distance: 70 inches (1.78 meter)
Usable Beam Width Is:
60 inches (1.52 meter)
29.8 inches (.76 meter) 27.6 inches (.70 meter) 25.5 inches (.65 meter)
55 inches (1.40 meter)
23.4 inches (.59 meter)
50 inches (1.27 meter) 45 inches (1.14 meter)
21.2 inches (.54 meter) 19.1 inches (.48 meter)
40 inches (1.02 meter)
17.0 inches (.43 meter)
65 inches (1.65 meter)
35 inches (.89 meter) 30 inches (.76 meter) 25 inches (.64 meter)
14.9 inches (.38 meter) 12.8 inches (.32 meter) 10.6 inches (.27 meter)
20 inches (.51 meter)
8.5 inches (.22 meter)
15 inches (.38 meter)
6.4 inches (.16 meter)
10 inches (.25 meter)
4.2 inches (.11 meter) Scan Angle = = Default
2–5
Page 32
2–6
Installation Considerations
Apparent Element Width
An element is either a bar or space between bars in a bar code. The maximum read range is determined by the narrowest element. If the bar code symbols are pitched with respect to the Reader, the apparent width of the bar code elements is reduced. This reduction in the element width affects the read range. When using the Read Range charts (page 2–8), use the apparent element width, not the actual element width. The apparent element width is calculated using: Apparent Element Width = Actual Element Width x Cosine (Pitch Angle)
For example, two boxes are scanned at a 0 and pitch. An enlarged area of 5 elements (3 black, 2 white) are shown as they would appear looking straight down the edge of the label.
Actual Element Width 10 mils
Actual Element Width 10 mils Pitch
Apparent Element Width 10 mils
Apparent Element Width 8.6 mils
The apparent element width above was calculated as follows. Apparent Element Width = 10 mil (0.25 mm) x Cosine = 8.6 mil (0.22mm)
Element widths are usually described in mil units. A mil is equivalent to 1/1000 of an inch (0.0254 mm).
Page 33
Installation Considerations
You can adjust the scan beam after the Reader is installed. Online adjustments can affect the width and location of the scan beam. Use these adjustments to fine-tune an application, not to compensate for improper installation. Chapter 6 describes how to make these adjustments.
• Scan Angle adjusts the beam width. Scanner
Optical Scan Angles➀
2755-SN3
22_
➁ to 72_
2755-SN5
20_ to 50_
2755-SN8
18_ to 30_
➀ Usable scan angle is 80% of the optical scan angle. ➁ Contact your Allen-Bradley representative for availability.
• Elevation (linear scanning only) adjusts the vertical angle at which the scan beam exits the Reader.
Center Line
3.6 inches (91 mm)
Reader Adjustments
2–7
Elevation can be adjusted from center line.
• Upper and Lower Raster Angles (raster scanning only) adjusts the highest and lowest raster angles. The range for each angle is 10 to -10_. The lower raster angle must be equal to or less than the upper raster angle. Upper Raster Angle from center line. Center Line
Lower Raster Angle from center line.
Page 34
2–8
Installation Considerations
Read Ranges
The following tables show tabular read range limits for the three versions of the AdaptaScan Readers.
➀ Read ranges based on four character Code 39 labels with a wide to narrow bar ratio of 2.6 to 1 and a print contrast ratio of .75 or better. Read ranges will vary with bar code symbol quality.
Table 2.A Read Ranges, Catalog No. 2755-SN3➀
➁ When scanning labels at an angle apparent element width is less than the actual element width. ➂ Read ranges measured from front edge of wiring base. Add .58 inches (.015 meter) for the distance to the scan window.
Read Range ➂
Minimum Apparent Element Width➁ Mils mm
Inches
Meters
5 6 7.5 10 13 15 20 25 30 35 40 45 50 55
.13 .15 .19 .25 .33 .38 .51 .64 .75 .89 1.02 1.14 1.27 1.40
1.9 - 3.6 1.9 - 5.3 1.4 - 7.2 1.4 - 10.9 1.4 - 16.2 1.4 - 19.5 1.4 - 28.4 1.4 - 36.8 1.9 - 42.9 1.9 - 51.4 1.9 - 59.3 2.4 - 64.4 2.9 - 69.4 3.4 - 74.6
.048 - .092 .048 - .135 .036 - .183 .036 - .277 .036 - .411 .036 - .495 .036 - .721 .036 - .935 .048 - 1.09 .048 - 1.31 .048 - 1.51 .061 - 1.64 .074 - 1.76 .086 - 1.89
Table 2.B Read Ranges Catalog No. 2755-SN5➀ Read Range Measured From This Point
Read Range ➂
Minimum Apparent Element Width➁ Mils mm
Inches
Meters
5 6 7.5 10 13 15 20 25 30 35 40 45 50 55
.13 .15 .19 .25 .33 .38 .51 .64 .75 .89 1.02 1.14 1.27 1.40
1.9 - 4.7 1.9 - 7.3 1.9 - 8.9 1.4 - 14.0 1.4 - 19.5 1.9 - 21.8 1.9 - 29.7 2.4 - 36.2 2.4 - 42.5 2.4 - 51.5 3.4 - 56.9 3.9 - 61.9 4.4 - 67.9 5.4 - 71.6
.048 - .119 .048 - .185 .048 - .226 .036 - .356 .036 - .495 .048 - .554 .048 - .754 .061 - .919 .061 - 1.08 .061 - 1.31 .086 - 1.44 .099 - 1.57 .112 - 1.72 .137 - 1.82
Table 2.C Read Ranges Catalog No. 2755-SN8➀ Minimum Apparent Element Width ➁ Mils mm 5 6 7.5 10 13 15 20 25 30 35 40 45 50 55
.13 .15 .19 .25 .33 .38 .51 .64 .75 .89 1.02 1.14 1.27 1.40
Inches
Read Range ➂ Meters
1.4 - 5.7 1.4 - 8.2 1.4 - 10.7 1.4 - 16.0 1.4 - 21.0 1.9 - 25.4 2.4 - 34.3 3.4 - 42.2 5.4 - 50.2 6.4 - 55.6 7.4 - 62.1 8.4 - 65.4 10.4 - 69.0 11.4 - 72.5
.036 - .145 .036 - .208 .036 - .272 .036 - .406 .036 - .533 .048 - .645 .061 - .871 .086 - .107 .137 - 1.27 .163 - 1.41 .188 - 1.58 .213 - 1.66 .264 - 1.75 .290 - 1.84
Page 35
Installation Considerations
Calculating Scans per Label
2–9
Use the following formulas to calculate the number of scans per label and the minimum number of scans per second needed for an application. The minimum scan speed required is based on five scans per label. Formulas Picket Fence Orientation
Step Ladder Orientation
Scans per Label =
(X-Y) A Z
A xH Z
Minimum Scan Speed Required =
Z x5 X-Y
Z x5 H
Where: A = Derated Scan Rate (Nominal Scan Rate –5%) = 285 SPS for Catalog No. 2755-SN3 Readers = 475 SPS for Catalog No. 2755-SN5 Readers = 760 SPS for Catalog No. 2755-SN8 Readers H = Height of bars in bar code. In inches ①. X = Usable beam length at minimum read distance. In inches ①. Y = Bar code length including quiet zones. Typically in inches ①. Z = Label speed. In inches per second ①. MINIMUM SCANS PER LABEL MUST BE = 5. ① You can use other units of measure, such as meters, as long as all measurements use the same unit.