Page 17

Overview

Wiring Base

1–9

The Reader plugs into a wiring base. All wiring base connections are made using common electrician tools. Install the Reader after the wiring base is installed to reduce the possibility of damage.

Reader

Wiring Base Four conduit entrances Terminal Blocks for I/O Modules Sockets for 2 I/O Modules Package Detect Terminal Block

DeviceNet Communication and Power Terminal Blocks

RS-422/RS-485 Communication Terminal Block

RS-232 Communication Terminal Block

Communication Termination Switches Reader Connector

Power Polarity – LED Indicator

DeviceNet/Power Terminal Blocks The wiring base has 2 identical terminal blocks; one for incoming power and communications, one for outgoing power and communications.

RS-232 Terminal Block Connections for point-to-point communications with a personal computer or controller RS-232 port.

RS-422 / RS-485 Terminal Block Connections for network or point-to-point communications with another RS-422/RS-485 device or network.

Page 18

1–10

Overview

Reader Connector The Reader plugs into this connector. All power and communications with the Reader occurs through this connector.

I/O Module Sockets Two sockets support any combination of the following input and output modules. See specifications in Appendix A. Description

Catalog Number

DC Output Module – rated at 3 to 60 VDC.

2755-OB5S

AC Output Module – rated at 12 to 140 VAC.

2755-OA5S

AC Output Module – rated at 24 to 280 VAC.

2755-OM5S

DC Input Module – accepts 3.3 to 32 VDC.

2755-IB5S

AC/DC Input Module – accepts 90 to 140 VRMS or VDC

2755-IA5S

AC/DC Input Module – accepts 180 to 280 VRMS or VDC

2755-IM5S

I/O Module Terminal Blocks Wiring connections for the optional input or output modules.

Package Detect Terminal Block Connects the contacts of a sensor, which detects the presence of a package in the Reader’s scan area. The package detect can be either an electronic (current sinking) or a hard contact type device. Most applications use a photo-reflective type sensor. The package detect starts and stops decoding and determines when messages are sent or when outputs are energized.

Power – Indicator LED Indicates normal operating and fault conditions. Condition

Indicates:

Green

Power on.

Red

Polarity of the power connections is reversed. Wiring must be corrected. No power.

Off

Termination Switches Terminates a DeviceNet and RS-422/RS-485 network. Terminate the two devices furthest away from each other on a network by moving the switch to the ON position.

Page 19

Overview

Communication Options

1–11

This section defines the communication options for the Reader.

DeviceNet Network AdaptaScan Readers support both DeviceNet Master/Slave and Peer-to-Peer protocols. On a DeviceNet Master/Slave network, Readers and other DeviceNet slave devices communicate with a DeviceNet Scanner (Master). Up to 63 slave devices are allowed on a master/slave network. On a DeviceNet peer-to-peer network, up to 32 Readers can be connected together. These Readers can:

• work in a coordinated mode to read multiple bar code symbols on different sides of the same package.

• combine data from several Readers to a single Reader that communicates the data to a host.

• pass input and output status information between Readers.

Reader

Reader Other DeviceNet Devices

PLC-5 with 1771-SDN (DeviceNet Scanner)

AdaptaScan Bar Code Readers operate on a DeviceNet network at the following baud rates (Kbps = Kilobits per Second): Baud Rate

Supports Maximum Cable Length of:

125 Kbps

1640 feet (500 meters)

250 Kbps

656 feet (200 meters)

500 Kbps

328 feet (100 meters)

Page 20

1–12

Overview

RS-422 / RS-485 An RS-422 / RS-485 port allows point-to-point communications with a single device. Through the RS-485 port, the AdaptaScan Reader can also communicate with a DH-485 network. Both master and slave modes are supported. As a master device, the Reader sends data directly to an SLC 5/03 or 5/04 processor’s data table; no polling is required by the SLC. As a slave device, the Reader connects to the Flexible Interface Module (Catalog No. 2760-RB) for multi-drop communications. SLC 5/04

Reader

Reader

DH485

DH485

Link Coupler

Note: You cannot use the RS-422/RS-485 port and the RS-232 port at the same time.

Page 21

Overview

1–13

RS-232 The RS-232 port provides point-to-point communications with a device having an RS-232 port, such as a PLC-5 Channel 0 port or computer. PLC-5

Channel 0 (Configured for RS-232) Reader

RS-232

Protocols The RS-485/RS-422 and RS-232 serial ports support these protocols. Protocol Allen-Bradley DF1 Allen-Bradley DH485 Terminal

Description A peer-to-peer protocol that combines features of ANSI X3.28-1976 specification subcategories D1 (data transparency) and F1 (two-way simultaneous transmission with embedded responses). A network protocol that allows DH485 devices (using the RS-485 standard) to communicate on the Allen-Bradley DH485 link. Provides a simple interface to most serial devices. This is the least secure protocol since it does not confirm the delivery or accuracy of messages. If security is required, we recommend that you use DF1 protocol with Block Check Characters (BCC) and ACK/NAK handshaking.

Page 22

1–14

Overview

AdaptaScan Software (Catalog No. 2755-ASN)

The AdaptaScan Software (Catalog No. 2755-ASN), a WindowsTM based package, lets you configure a Reader through a series of menus, tools and dialog boxes. Context sensitive help is available to assist with use of the software. All Reader functions are configured from the Project dialog shown below, providing a single point of access for all operations.

The Project window has buttons for accessing these operations. Select:

To: Define label setup and symbologies for Reader operation. Define a unique name, node address, and description for the Reader. Define scanning parameters and access the focus function. Define the Reader trigger source for decoding and what symbols are decoded. Also configures the intersymbol timer and performance indicator. Define the operation for package detector, discrete inputs, discrete outputs, timer and ASCII trigger commands. Define communication parameters (RS-232, RS-422, RS-485) and protocols (ASCII, DH485, DF1) for the Reader’s communication ports. Define match table, package and counter functions for decoded bar code data. Define the format and content of bar code messages sent to the host by the Reader. Transfer configurations to all Readers on the same DeviceNet network. Transfer a configuration to selected Reader. Download new firmware to a Reader. View the operation of a Reader. Deletes the selected Bar Code Reader configuration from the Project window. Creates a new Bar Code Reader configuration (Bar Code Reader 1, Bar Code Reader 2, Bar Code Reader 3, ...) in the Project window.

Page 23

Overview

1–15

Scanning Parameters You can configure the Reader for linear or raster scanning. Setup dialogs determine when and how the laser scans a bar code symbol.

Raster Setup

Linear Setup

Focus Options The Reader has a variable focus distance. The software supports manual, preset, and focus options.

• Manual Manual adjustment of the read range allows you to fine-tune the focus setting for a maximum read percentage.

• Preset Four preset read ranges (A, B, C, C+) correspond approximately to bar code scanners (Catalog No. 2755-LD4, -LD8), allowing for easy replacement of these scanners. See Chapter 2 for read ranges.

• AutoFocus The Reader scans for a label from the nearest to the farthest focal distance. The number of reads at each distance is determined and the focal distance is set halfway between the nearest and farthest focal distance where 100% valid reads occur. The dialog shows the autofocus function graphically.

Focus Setting

Page 24

1–16

Overview

Decoding Operations Menus and dialog boxes also define parameters that determine when and how decoding occurs and the destination of the data.

System Monitoring The software monitors a Reader on the network. Use this feature for initial setup and adjustment.

Online Adjustments Make online adjustments to one or more Readers on a DeviceNet network using the Apply button which is available on specific dialogs. This allows fine tuning of an entire system from a single connection.

Page 25

Overview

Safety Labels

1–17

The Readers use a visible laser diode. As with any bright light source, such as the sun, you should avoid staring directly into the beam. Momentary exposure to a CDRH Class II laser product is not known to be harmful. The following shows the location of all safety labels as they appear on the Reader.

!

ATTENTION: Use of controls, adjustments, or procedures other than those specified herein may result in hazardous laser light exposure.

Page 26

1–18

Overview

Ordering Information

The following Readers are available. Item

Description

300 scans per second, raster/linear scan, VLD, scanner/decoder 500 scans per second, raster/linear scan, Reader VLD, scanner/decoder 800 scans per second, raster/linear scan, VLD, scanner/decoder ➀ Contact Allen-Bradley for availability.

Catalog No. 2755-SN3➀ 2755-SN5 2755-SN8

The following items are available. Each installation requires one AdaptaScan Software package (Catalog No. 2755-ASN) and one Communication Cable (Catalog No. 2755-NC48). Item Wiring Bases

AdaptaScan Software

Window Kits

Description Reader wiring base: US version Metric version Each Reader requires one wiring base. Windows based software used on a personal computer for creating configurations for AdaptaScan Bar Code Readers. Replacement scan window kit includes window - bezel - gasket assembly along with mounting screws and instructions. Plastic window kit Glass window kit

Catalog No. 2755-NB40 2755-NB41

2755-ASN

2755-NW44 2755-NW45

24 VDC power supply powers one Reader. Power Supplies

Mounting Bracket Kit

Communication Cable

I/O Modules

120 VAC Input, 60 Hz (US) – Wall mount 240 VAC input, 50 Hz (European) – Desktop Mounting bracket attaches to the wiring base and provides almost any combination of tilt, pitch and rotational positioning. 9 foot, 10 inch (3 meter) cable connects Reader configuration port to a computer. Has a 9-pin D shell connector for the computer’s RS-232 serial Com port. Note: The Series A Reader uses the 2755-NC43 programming cable. This cable is not compatible with the Series B Reader. Refer to page 1–10.

2755-PW46 2755-PW47 2755-NM42

2755-NC48