The text of a manual · part 2 of 15
AdaptaScan Bar Code Readers User Manual (Cat. No. 2755-SN3, -SN5, -SN8), pages 7 to 16
Pages 7 to 16 of 96: Preface - Using this Manual; 1 - Overview
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 7
Preface
Using this Manual Chapter Objectives
Read this chapter to familiarize yourself with the rest of the manual. You will learn about:
• • • • •
Overview of this Manual
Contents of this manual Intended audience Terminology CE Directives Related publications
The following table describes the contents of each chapter in this manual. Chapter
Title
Purpose
Preface
Provides an overview of the manual.
1
Overview
Describes the main features and operating capabilities of the AdaptaScan Reader.
2
Installation Considerations
3
Installing the Wiring Base and Power Supply
4
Installing / Removing the Reader
5
Downloading Configurations
6
Troubleshooting and Maintenance
Describes the factors that determine the optimum placement of the Reader. Describes how to mount and wire the Reader wiring base. Describes installation and initial powerup of the Reader. Instructions on how to remove a Reader are also provided. Describes how to download firmware and Reader configurations. Provides assistance in identifying and correcting common operating problems. Procedures for routine maintenance items are also provided.
Page 8
P1–2
Using this Manual
Intended Audience
Because the AdaptaScan Software runs in the Microsoft Windows environment, you should know how to use a mouse, choose commands, and work with windows and dialogs. You should also have a basic understanding of PLC and SLC Controllers. Equipment installers must be familiar with standard wiring techniques and terminology.
Terminology
This manual contains some terms that may be unfamiliar. Use the glossary at the back of this manual for assistance. The AdaptaScan Bar Code Readers (Catalog No. 2755-SN3, -SN5, -SN8) are referred to as Readers.
CE Directives
If the AdaptaScan Reader is installed within the European Union, Appendix C provides the legal requirements.
Related Publications
The following table lists other publications related to the AdaptaScan Bar Code Reader. Publication Number
AdaptaScan Software User Manual
1485-6.7.1
DeviceNet Cable System Planning and Installation Manual
1787-6.5.3
Data Highway / Data Highway Plus / Data Highway-485 Cable Installation Manual DeviceNet Manager Software (Catalog No. 1787-MGR) User Manual
1749-6.5.5
DeviceNet Adapter Module (Catalog No. 1749-ADN) User Manual
1747-6.5.2
DeviceNet Scanner (Catalog No. 1747-SDN) Configuration Manual
1771-6.5.118
DeviceNet Scanner (Catalog No. 1771-SDN) Configuration Manual
1770-6.2.2
Technical Support
Description
2755-838
If you should require assistance or need additional information on operating the AdaptaScan Reader, Configuration Software, or accessories, contact your local Allen-Bradley Support office or Allen-Bradley Technical Services at (216) 646-6800.
Page 9
Chapter
1
Chapter Objectives
Series B Changes
This chapter briefly describes the AdaptaScan Bar Code Reader. Section
Page
Typical System
1–2
Reader
1–3
Typical Applications
1–5
Scanning Modes
1–8
Wiring Base
1–9
Communication Options
1–11
AdaptaScan Software
1–14
Safety Labels
1–17
Options and Accessories
1–18
If you are familiar with the Series A Reader and/or are replacing a Series A Reader, note the following changes in the Series B versions.
• New programming port connector, programming cable and dust cap. • Soft-start power circuit reduces the current inrush when power is supplied. This allows more Readers to be powered using a single supply. The soft–start circuit also allows the use of current limited power supplies. Programming Cable Catalog No. 2755-NC48 New Programming Connector
Dust Cap
Important: The Series A Reader uses the 2755-NC43 programming cable. This cable is not compatible with the Series B Reader.
Page 10
1–2
Overview
Typical System
A typical AdaptaScan installation consists of:
• Reader • Wiring Base • Package Detector Personal Computer (For Configuration and Setup)
Configuration Cable
Reader
Wiring Base
To Network or Control Device
Package Detector
The Reader is configured using the AdaptaScan Software (Catalog No. 2755-ASN) and configuration cable (Catalog No. 2755-NC48). One software package and configuration cable is required per installation.
Page 11
Overview
1–3
Reader LED Indicators Configuration Port Connector
Scan Window
Dust Cap
Wiring Base Connector
The Reader scans and decodes bar code symbols. The integral decoder decodes the most common bar code symbologies. The scan and decode functions are configured using software on a personal computer. Three scan speeds are available: ➀
Catalog Number
Scan Rate
2755-SN3 2755-SN5 2755-SN8
Optical Scan Angle Minimum
Maximum
300
500
800
➀ Usable scan angle is 80% of the optical scan angle.
Scan Window The replaceable scan window allows laser light to exit the Reader. Light reflects off the bar code symbol, passes back through the scan window and is decoded by the Reader. The scan window can be replaced with a glass or plastic window. See page 1–18 for details on replacement window kits.
Configuration Port Connector The RS-232 port allows a personal computer running the AdaptaScan Software (Catalog No. 2755-ASN) to download a configuration to one or more Readers. The Configuration Port Connector is for temporary use during configuration transfers and system setup.
Page 12
1–4
Overview
LED Indicators Seven LEDs provide the following indications. Indicator
Module
Condition
Indicates:
Green Flashing Green
Normal operating state Initialization and/or incorrect (unconfigured) configuration Processor fault (nonrecoverable) Minor fault (recoverable). Occurs when downloading firmware. No power applied to Reader Normal DeviceNet operating state Communication link established, but not data transfer. Communication fault One or more DeviceNet devices are not responding. Reader may not be able to perform all configured functions.
Red Flashing Red Off Green Flashing Green
Network
Laser On
On Symbol
Trigger / Read
I/O 1 I/O 2
Red Flashing Red
Off Yellow Off Yellow Flashing Off Yellow Green Off Yellow Off Yellow Off
DeviceNet communications not established Scan beam on Scan beam off Scanning and decoding bar code symbol Bar code symbol read at less than 100% rate Not scanning bar code symbol Package detected Valid read No trigger or no valid bar code symbol read Input/Output module 1 active Input/Output module 1 not active Input/Output module 2 active Input/Output module 2 not active
Wiring Base Connector The 24-pin connector on the bottom of the Reader plugs into the socket on the wiring base. No other connections to the Reader are required.
Operating Environment The Reader operates under a variety of conditions.
• Cast aluminum enclosure meets NEMA Type 4 requirements when used with the wiring base.
• Operates in environments from 32 to (0 to • Mounts at any angle. See Appendix A for a complete list of Reader specifications.
Page 13
Overview
Typical Applications
1–5
The flexibility of the Reader allows you to configure it for a variety of applications. This section shows the basic system types.
Standalone In a typical standalone setup, a single Reader scans bar codes on the side of a package moving down a conveyor.
➂ ➄ ➃
➀ ➁
The package crosses the beam between the package detector ➀ and reflector ➁. The Reader ➂ scans and decodes bar code symbols on the package. You can configure the decoder with match table data. When decoded data is matched, the Reader turns on an output module (in wiring base ➃) to control the operation of a diverter ➄ that directs the package to a location.
Page 14
1–6
Overview
Distributed (DeviceNet Master/Slave, DH-485) The distributed application below shows three Readers scanning bar codes at different points in an assembly process. Data from any Reader is individually sent to a controller. The discrete I/O on each Reader provide distributed control independent of the PLC monitoring the process. Controller
➁
➃
➂
➀
Reader ➀ identifies major sub-assemblies for routing to the proper final assembly area. Reader ➁ verifies the product code on the assembled product being shipped. Reader ➂ verifies that the shipping label matches the product code. PLC ➃ monitors the process.
Page 15
Overview
1–7
Distributed (DeviceNet Peer-to-Peer) Peer-to-Peer communications allows a single Reader to gather data from other Readers over a DeviceNet network. The Reader then transfers the collected data to a host, such as a controller, over an RS-232 link.
➁
➂
➄
➀
➃
Readers ➀ through ➃ transfer data over a DeviceNet network to Reader ➂ which collects the data and then transfers the data over an RS-232 link to the host ➄.
Page 16
1–8
Overview
Scanning Modes
You can configure a Reader as either a linear or raster scanner. The orientation of the bar code label with the scanner usually determines the scanning mode appropriate for the application. Linear Mode Scan Line Elevation is adjustable. Linear
In the linear scan mode, the scan line elevation can be be adjusted. Raster Mode Upper and lower raster limits are adjustable. Raster Flyback quickly returns the scan line to the upper raster limit after the lower limit is reached.
Raster increment is adjustable. Increment increases / decreases the number of scan lines in the raster pattern.
In raster scan mode, you can adjust or select:
• Upper and lower raster limits Upper Raster Angle
Lower Raster Angle
• Raster increment
Decrease
• Flyback enable
Flyback
Increment
Increase