For the Allen-Bradley 2755-LS7
Page 76
Configuring Your Reader
5–31
• Auxiliary Port Command Mode 0 = Disabled 1 = Transparent 2 = Half-duplex 3 = Full-duplex 4 = Slave Mode Baud Rate 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19200 6 = 38400 7 = 76800 8 = 300 Parity 0 = None 1 = Even 2 = Odd Stop Bits 0 = One 1 = Two Data Bits 0 = Seven
Parameter
Ky
Format
Example
<Ky mode,baud rate,parity,stop bits,data bits>
To change Auxiliary Port Baud Rate to 2400, press [<Ky2>].
1 = Eight
• Communications Status Request. Allows you to return the status of each command in the group. Parameter KT
Format <KT?>
Operations Commands
• Triggering Mode. The trigger filtering time occurs in 128 microsecond increments. You can use any number between 2 and 255. The default is 78 (approximately 10 seconds). Command Triggering Mode 0 = Continuous Read 1 = Continuous Read, 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and Edge
Parameter
Kg
Format
<Kgtriggering mode,filter time>
Example
To select External edge, press [<Kg3>].
Publication 2755-6.9
Page 77
5–32
Configuring Your Reader
• End of Read Cycle. The timeout occurs in 10 millisecond increments. You can use any number between zero and 65535. The default is 100 (one second). Command
Parameter
End of Read Cycle Mode 0 = Timeout 1 = New Trigger
Kh
Format <Khend of read cycle mode,timeout>
Example To select Timeout and change the timeout value to 6 seconds, press [<Kh0,600>].
2 = Timeout and New Trigger
• Serial Trigger Character. You can use any available ASCII character. The default character is ^. Pressing [<^>] when using the default character with the serial triggering mode selected, will trigger the reader. Parameter Ki
Format
Example
<Kiserial trigger character>
To define the Serial Trigger Character as a lower case c, press [<Kic>].
• External Trigger Level Command External Trigger Level 0 = Negative 1 = Positive
Parameter Kj
Format <Kjexternal trigger level>
Example To change External Trigger Level to negative, press [<Kj0>].
• Good Decode Reads. You can use any number between 1 and 31. The default is 1. Parameter Km
Format <Kmnumber of reads>
Example To change Good Decode Reads to 3, press [<Km3>].
• Match Code Type Command Status 0 = Disabled 1 = Enabled 2 = Sequential 3 = Wild Card Sequential Matching 0 = Increment 1 = Decrement Match Start Position 0 to 64. 0 is the default. Match Length 1 to 64. 1 is the default. Wild Card Character Any character. * (asterisk) is the default.
Publication 2755-6.9
Parameter
Kn
Format
Example
<Kntype,sequential matching,match start position,match length,wild card character,sequence on no read,sequence on every mismatch>
To enable Match Code Type for Sequential, set Sequential Matching for Decrement, and enable Sequence on Every Mismatch, press [<Kn2,1,,,,,1>].
Page 78
Configuring Your Reader
5–33
For a sequence on a No Read, refer to the following table. When disabled, the reader does not sequence (increment or decrement) on a No Read. When enabled, the reader sequences on every No Read. Command
Example
Status 0 = Disabled
If 001, 002, No Read, then search for 003.
1 = Enabled
If 001, 002, No Read, then search for 004.
For a sequence on every mismatch, refer to the following table. When disabled, if a mismatch is out of sequence by more than 1, the sequence resumes. When enabled, the reader sequences the on every mismatch. Command
Example
Status 0 = Disabled
If 001, 002, 004 (mismatch), then search for 005.
1 = Enabled
If 001, 002, mismatch, then search for 004.
• New Master Pin Command Status 0 = Disabled 1 = Enabled
Parameter Kz
Format <Kzstatus>
Example To enable New Master Pin, press [<Kz1>].
• Number of Labels. You can use any number between 1 and 6. The default is 1. The multilabel separator is any valid ASCII character. Parameter KL
Format <KLnumber, multilabel separator>
Example To change Number of Labels to 3, press [<KL3>].
• Operations Status Request. Allows you to return the status of each command in the group. Parameter KV
Format <KV?>
Code Types Commands
• Narrow Margins Command Status 0 = Disabled 1 = Enabled
Parameter Ko
Format <Konarrow margin status,symbology ID status>
Example To enable Narrow Margins, press [<Ko1>].
Publication 2755-6.9
Page 79
5–34
Configuring Your Reader
• Code 39. You can use any number between 1 and 64 for the Fixed Code Length. The default is 10. Command Status 0 = Disabled 1 = Enabled Check Digit Status 0 = Disabled 1 = Enabled Check Digit Output Status 0 = Disabled 1 = Enabled Large Intercharacter Gap 0 = Disabled 1 = Enabled Fixed Code Length Status 0 = Disabled
Parameter
Kp
Format
Example
<Kpstatus,check digit status,check digit output status,large intercharacter gap,fixed code length status,code length>
To set Fixed Code Length to 30, press [<Kp,,,,1,30>] or [<Kp1,0,0,0,1,30>].
1 = Enabled
• Codabar. You can use any number between 1 and 31 for the Fixed Code Length. The default is 10. Command Status 0 = Disabled 1 = Enabled Start and Stop Match Status 0 = Disabled 1 = Enabled Start and Stop Output Status 0 = Disabled 1 = Enabled Large Intercharacter Gap 0 = Disabled 1 = Enabled Fixed Code Length Status 0 = Disabled 1 = Enabled Check Digit Output 0 = Disabled 1 = Enabled Check Digit Type 0 = Disabled 1 = Mod 16 2 = NW7 3 = Both
Publication 2755-6.9
Parameter
Kq
Format
<Kqstatus,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,code length,check digit type,check digit output>
Example
To set Fixed Code Length to 9, press [<Kq1,,,,1,9>] or [<Kq1,1,1,0,1,9>].
Page 80
Configuring Your Reader
5–35
• I 2 of 5. Code length #1 can be zero or any even number from 2 to 64. The default is 10. Code length #2 can be zero or any even number from 2 to 64. The default is 6. Command Status 0 = Disabled 1 = Enabled Check Digit Status 0 = Disabled 1 = Enabled Check Digit Output Status 0 = Disabled
Parameter
Kr
Format
Example
<Krstatus,check digit,check digit output,length 1, length 2>
To set Fixed Code Length #1 to 8 and #2 to 4, press [<Kr1,,,8,4>] or [<Kr1,0,0,8,4>].
1 = Enabled
• UPC/EAN. The Separator character can be any ASCII character except NUL. The default is , . Command UPC Status 0 = Disabled 1 = Enabled EAN Status (UPC must be enabled) 0 = Disabled 1 = Enabled Supplementals Status 0 = Disabled 1 = Enabled 2 = Required Separator Status 0 = Disabled
Parameter
Format
<KsUPCstatus,EAN status,supplementals status,separator status,separator cha.>
Ks
Example
To change Supplementals to Required, and change Separator Character to a dash (–), press [<Ks1,1,2,1,–>].
1 = Enabled
• Code 128. You can use any number between 1 and 64 for the Code Length. The default is 10. Command Status 0 = Disabled 1 = Enabled Fixed Code Length Status 0 = Disabled 1 = Enabled
Parameter
Kt
Format
<Ktstatus,fixed length,length>
Example
To enable Code 128, enable Fixed Code Length, and set Code Length to 9, press [<Kt1,1,9>].
• Code Types Status Request. Allows you to return the status of each command in the group. Parameter KW
Format <KW?>
Publication 2755-6.9
Page 81
5–36
Configuring Your Reader
Scanner Output Commands
• Relay–1. The pulse width occurs in 10 millisecond increments. You can use any number between 2 and 255. The default is 5. Command
Parameter
Output On 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read Polarity 0 = Negative 1 = Positive
Kv
Format
Example
<Kvoutput on,polarity,pulse width>
To set Relay 1 to Mismatch and change Pulse Width to 40 ms, press [<Kv2,0,4>] or [<Kv2,4>].
• Relay–2. The pulse width occurs in 10 millisecond increments. You can use any number between 2 and 255. The default is 5. Command
Parameter
Output On 0 = Mismatch or No Read 1 = Match or Good Read 2 = Mismatch 3 = No Read Polarity 0 = Negative 1 = Positive
Kw
Format
Example
<Kwoutput on,polarity,pulse width>
To set Relay 2 to Mismatch and change Pulse Width to 40 ms, press [<Kw2,0,4>] or [<Kw2,4>].
• Bar Code Output Command
Parameter
Status 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read When to Output 0 = As soon as Possible 1 = End of Read Cycle
KI
Format
Example
<Klstatus,when to output>
To set When to Output to End of Read Cycle, press [<KI3,1>].
• No Read Message. You can use any ASCII string up to 7 characters in length. The default is No Read. Command Status 0 = Disabled 1 = Enabled
Publication 2755-6.9
Parameter Kk
Format <Kkstatus,output>
Example To enable No Read Message and send the message FAIL, press [<Kk1,FAIL>].
Page 82
Configuring Your Reader
5–37
• Beeper Command Beeper Status 0 = On Good 1 = On No Read Beeper Volume 0 = Off 1 = Level 1 2 = Level 2 3 = Level 3 4 = Level 4 5 = Level 5
Parameter
Ku
Format
<Kustatus,volume>
Example
To set the beeper for On No Read and set the beeper volume to Off, press [<Ku1,0>].
• Laser On/Off Command Status 0 = Disabled 1 = Enabled
Parameter KC
Format <KCstatus>
Example To enable Laser On/Off, press [<KC1>].
• Serial Verification Command Serial Command Echo Status 0 = Disabled 1 = Enabled Serial Command Beep Status 0 = Disabled 1 = Enabled Control/hex Output 0 = Control 1 = Hex
Parameter
KS
Format
<KSserial command status,serial command beep status,control/hex output>
Example
To enable Serial Command Echo Status, Beep status, and Hex Output, press [<KS1,1,1>].
• User Output Status Request. Allows you to return the status of each command in the group. Parameter KX
Format <KX?>
• Partial Label Output. Allows you to transmit a portion of the label to the host. Command Status 0 = Disabled 1 = Enabled Start Position 1 to 63. 1 is the default. Length
Parameter
KY
Format
<KYstatus,start position,length>
Example
To enable Partial Label Output starting at character 4 and ending at character 8 of the string, press [<KY1,4,5>].
1 to 63. 63 is the default.
Publication 2755-6.9
Page 83
5–38
Configuring Your Reader
Scanner Setup Commands
• Scanner Type. You determine the type of reader you are using. Entering the <Zp> command will save the current setting for Scanner Type to NOVRAM. Command Scanner Type 0 = Standard 1 = High Density
Parameter KP
Format <KPdensity>
Example Do not change the reader type.
• Scans per Second. The scan occurs in 10 millisecond increments. You can use any number between 30 and 55. The default is 50. Parameter KE
Format <KEspeed>
Example To set the reader to 400 scans per second, press [<KE40>].
• Auto Gain Control. Gain adjustment can be any number from 10 to 255. The default is 45. Before saving any changes to Gain Adjustment, first record the optimized factory setting for future reference. Press [<KU?>] to read factory settings. Command AGC Sampling 0 = Disabled 1 = Leading Edge 2 = Continuous
Parameter
KD
Format
Example
<KDgain adjustment,AGC sampling,tracking>
To set the gain threshold to 40 and the AGC status to Leading Edge, press [<KD40,1,0>].
• Bad Bar Code Message. You can use any ASCII string up to 7 characters. The default is Bad Code. Command Status 0 = Disabled 1 = Enabled
Parameter KM
Format <KMstatus,message>
Example To change the message to “FAULTY”, press [<KM1,FAULTY>].
• No Bar Code Message. You can use any ASCII string up to 7 characters. The default is No Label. Command Status 0 = Disabled
Parameter KN
Format <KNstatus,message>
1 = Enabled
Example To change the message to “NO LABEL, press [<KN1,NOCODE>].
• No Object Message. You can use any ASCII string up to 7 characters. The default is Missing. Command Status 0 = Disabled 1 = Enabled
Publication 2755-6.9
Parameter KO
Format <KOstatus,message>
Example To change the message to “VACANT”, press [<K01,VACANT>].
Page 84
Configuring Your Reader
5–39
• Scanner Setup Status Report. Allows you to return the status of each command in the group. Parameter KU
Decode Test
Format <KU?>
To test the decode rate: 1. Position the label in front of a functioning reader. 2. Press [<C>] from the host terminal to launch the decode rate test. 3. Observe decode rate. 4. Check depth-of-field (minimum/maximum range) by moving the label closer and further relative to the reader and noting the points where the decode rates fall below a level acceptable to your application. The label used in your application should pass through or near the center of the depth-of-field. 5. Repeat steps 1 through 5 for other labels used in your application and end the decode rate test by pressing [<J>]. If the decode rate is acceptable, no adjustments are needed to your reader. If the decode rate is unacceptable, adjust your reader parameters. Note: If, after making adjustments, you have changed the read range or another parameter used in the number of scans formula, you should recalculate the number of scans. Note: Variations between labels are common. For this reason, the greater number of sample labels you test, the more likely you are to achieve optimum decode rates.
Adjusting Reader Parameters
To help improve decode rates, adjustments can be made in the following areas.
Scan Rate Scan rate is a function of motor speed and is adjustable from 300 to 550 within the Scanner Setup menu. The reader is factory set at the rate of 500 scans per second. A slower scan rate may allow greater label range and/or higher decode rates, but at the cost of fewer scans per label. To adjust the scan rate (motor speed), press [<D>] and select the Scanner Setup menu.
Publication 2755-6.9
Page 85
5–40
Configuring Your Reader
Range Adjusting the label’s range, if possible, is one of the quickest and most effective ways to improve decode rates. However, in some applications you may need to select a less than optimum range, or one that is beyond the fringes of the ranges.
Scan Width Increasing scan width will increase the number of scans in a picket fence oriented application. Scan width is linked with scan range and changing one will usually require a change in the other.
Label Speed Applies to both picket fence and step ladder oriented labels. If your application allows it, label speed (the time in seconds that a label is fully within the scan width of the reader) is an effective way to alter the number of scans.
Label Dimensions, Label Density, and Label Ratio Not usually an option in most applications, but changes to label parameters can affect number-of-scan calculations and possibly decode rates. If your application allows it, shortening the length of a picket fence label means the label will be in the scan range longer and hence receive a greater number of scans. Increasing the height of a step ladder label means it will receive more scans. Changing label density and/or bar code ratio is another way ranges, decode rates, etc. can be altered.
Gain This adjustment, typically made by qualified technicians, is done from within the Scanner Setup menu.
Publication 2755-6.9