For the Allen-Bradley 2755-LS7

Page 86

Chapter

6

Hardware Operation This chapter provides information on how to operate your scanner system hardware. Items include: • using operational commands • operating scanner system hardware

Using Operational Commands

On-line serial operational commands are sent from the host to the reader to carry out routine operations “on the fly” as distinguished from serial configuration commands that are generally used in initial setup. Operational commands are preceded by a < left angle bracket symbol and followed by a > right angle bracket symbol. Command start character by default is a left angle bracket, <. It may be redefined by menu or serial command. However, the end character, a right angle bracket, >, cannot be changed. The table on the next page lists the operational commands.

Publication 2755-6.9

Page 87

6–2

Hardware Operation

Function

Program Management

Device Control

Code Types

Counter

Test

Status

Command <A> <Ad> <An> <D> <Z> <Zd> <Zp> <H> <I> <KE> <KF> <L1> <L2> <P> <Q> <R> <S> <N> <O> <T> <U> <V> <W> <X> <Y> <C> <Ce> <J> <#> <!> <?> <?1>

Master Label

<E> <F> <G> <)XXXX)> <)> <))> ➀

Publication 2755-6.9

Action Software Reset (does not save for power-on) Software Reset/Restore Default Software Reset/Read NOVRAM Enter Configuration Mode Software Reset/Save Parameters for Power-on Restore/Save Default Configuration for Power-on Save Scanner Type, SPS, and Gain for Power-on Enable Laser Scanning (Laser On) Disable Laser Scanning (Laser Off) Motor On Motor Off Relay-1 Pulse Relay-2 Pulse Autodiscriminate All Codes Enable Code 39 Only➀ Enable Codabar Only➀ Enable I 2 of 5 Only➀ No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Match Code/Good Read Counter Match Code/Good Read Counter Reset Mismatch Counter Mismatch Counter Reset Enter Decode Rate Test Enter Extended Decode Rate Test Exit Decode Rate Test; Exit Extended Decode Rate Test Display Software Part Number Display Checksum of EPROM Show Scanner Status Show Software Status (Send Status Byte, Part Number, and ROM Checksum. Display NOVRAM Checksum at Power Up, then Display Current NOVRAM Checksum) Enable Match Code Option➀ Disable Match Code Option➀ Store Next Label Scanned as Master Label Download Master Label Information Request Master Label Information Delete Master Label Information

The command can also be set in the configuration menu or with a serial configuration command.

Page 88

Hardware Operation

6–3

Program Management Commands • Software Reset, [<A>]. Initializes all serial configuration

• • • •

•

• commands in RAM and resets all counters and operating parameters. Note: Software Reset will cause the numeric counters in use to lose their count; record all data that you wish to save prior to sending this command. Software Reset/Restore Default, [<Ad>]. Restores the ROM default values to RAM then initializes them. Does not effect Scanner Type, Scans per Second, or Gain Adjustment. Software Reset/Read NOVRAM, [<An>]. Reads the NOVRAM settings then initializes them to RAM. Enter Configuration Mode, [<D>]. Enters the Menu Configuration Program. Software Reset/Save Parameters for Power-on, [<Z>]. Allows you to save all but Scanner Type, Scans per Second, and Gain Adjustment to NOVRAM. The values of numeric counters are not saved by this command. Note: The Software Reset/Save Parameters for Power-on command can be executed at least 10,000 times. In normal usage this will exceed the life of the reader. If frequent changes to the operating parameters are required, it is recommended that the <Z> command be used only when the current configuration has been changed and the changes are to be permanent. Restore/Save Default Configuration for Power-on, [<Zd>]. Allows you to restore and save default settings for all but Scanner Type, Scans per Second, and Gain Adjustment to NOVRAM. Note: Power must be available to the reader during the default procedure. Defaulting might be necessary after temporary changes or if communications between the reader and another device are lost or interrupted, or if you are using incompatible equipment. For example, a terminal is set to communicate at 9600 baud, but the reader is configured at 38.4K baud. Save Scanner Type, SPS, and Gain for Power-on, [<Zp>]. Allows you to save the current settings for Scanner Type, Scans per Second, and Gain Adjustment to NOVRAM. Once you send this command, default values can only be recalled if you reenter them individually and then save them again with this command. Note: This command will replace the optimized factory setting for Gain Adjustment with your new setting; record and save this setting for future reference prior to sending this command.

Publication 2755-6.9

Page 89

6–4

Hardware Operation

Device Control Commands • Enable Laser Scanning (Laser On), [<H>]. • Disable Laser Scanning (Laser Off), [<I>]. This feature is useful

• • • • during extended periods of time when no bar code labels are being scanned. Disabling laser scanning will not affect any downloaded commands to the reader. Motor On, [<KE>]. Turns the motor on (reaches full speed after a short time delay). Motor Off, [<KF>]. Turns the motor off. Relay-1 Pulse, [<L1>]. Allows you to send a pulse to pin 7 (at any time regardless of Match Code or Relay-1 Driver status). Relay-2 Pulse, [<L2>]. Allows you to send a pulse to pin 14 (at any time regardless of Match Code or Relay-2 Driver status).

Code Types Commands • Autodiscriminate All Codes, [<P>]. Enables the reader to decode all available bar code types without changing reader configuration settings. Note: For maximum scanning speed, enable only those bar code symbologies used in the application. • Enable Code 39 Only, [<Q>]. Allows only Code 39 labels to be read. • Enable Codabar Only, [<R>]. Allows only Codabar labels to be read. • Enable I 2 of 5 Only, [<S>]. Allows only Interleaved 2 of 5 labels to be read.

Counter Commands The Xs in all counter commands that follow denote a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, you will receive an error message and the counter will automatically rollover and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65,536 per each rollover (the reader does not keep track of the number of rollovers) to the current count. Note: You will lose all counter values if you cycle power to the reader, press [<A>], or enter the Menu Configuration Program.

Publication 2755-6.9

Page 90

Hardware Operation

6–5

Note: If you activate the counter command during a read cycle, the reader will not output the count until the read cycle ends. • No Read Counter, [<N>]. The message N/XXXXX displays the total number of no reads that have occurred since power-on or the last No Read Counter Reset command. • No Read Counter Reset, [<O>]. Sets No Read Counter to 00000. • Trigger Counter, [<T>]. The message T/XXXXX displays the total number of triggers since power-on or the last Trigger Counter Reset command. • Trigger Counter Reset, [<U>]. Sets the trigger counter to 00000. • Match Code/Good Read Counter, [<V>]. The message V/XXXXX displays either (1) the total number of good reads that match the master label or (2) the total number of good reads, or decodes. The count begins from the last power-on or Match Code/Good Read Counter Reset command. To count the good reads that match the master label, enable Match Code; to count good reads only, disable Match Code. This counter is always active and can be requested at any time. • Match Code/Good Read Counter Reset, [<W>]. Sets the Match Code/Good Read Counter to zero. • Mismatch Counter, [<X>]. The message X/XXXXX displays the number of labels successfully read that do not match the master label since power-on or the last Mismatch Counter command. • Mismatch Counter Reset, [<Y>]. Sets the Mismatch Counter to zero.

Test Commands • Enter Decode Rate Test, [<C>]. Instructs the reader to output the decode rate and label data (if any). (If in a triggered mode, the reader will output the number of good reads based on the number of accepted triggers received.) The decode rate can vary dramatically due to the angle and location of the label in relation to the scan beam (or scan line, if using a scan head with a moving beam). This test is very useful in aligning and positioning the scanning device during installation. • Enter Extended Decode Rate Test, [<Ce>]. Instructs the reader to output decode rate, label data (if any), reflectance threshold, and number of label space transitions. This test is necessary to determine how to set Minimum Label Transitions and Reflectance Threshold. • Exit Decode Rate Test, [<J>]. Ends both the decode rate test and the extended decode rate test. Note: It is not necessary to use the <J> command while switching between the decode rate test and the extended decode rate test. Publication 2755-6.9

Page 91

6–6

Hardware Operation

Status Commands • Display Software Part Number, [<#>]. Displays software part number. • Display Checksum of EPROM, [<!>]. Displays a four-digit hex number (corresponding to a given firmware version) used to verify a reader’s EPROM. • Show Scanner Status, [<?>]. This command is used to display certain operating parameters (NOVRAM, command, and operation status). After sending this command, the reader immediately responds with <X>, where “X” is an ASCII character. Refer to appendix C for the ASCII table. To check the reader’s status: A. Locate the ASCII character’s Hex value in the ASCII table. For example, the ASCII character “M” has a hex. value of 4D. B. Compare the hex value to the binary equivalent in the table below. The binary equivalent of 4D is 01001101. The 0100 is the binary equivalent of the 4 and 1101 is the binary equivalent of the D. Hex. Value

Publication 2755-6.9

Binary Bit Digits

00

0

0

0

0

01

0

0

0

1

02

0

0

1

0

03

0

0

1

1

04

0

1

0

0

05

0

1

0

1

06

0

1

1

0

07

0

1

1

1

08

1

0

0

0

09

1

0

0

1

0A

1

0

1

0

0B

1

0

1

1

0C

1

1

0

0

0D

1

1

0

1

0E

1

1

1

0

0F

1

1

1

1

Page 92

Hardware Operation

6–7

C. Compare the bit digits (1 or 0) to each bit location to determine the reader function. For the binary number 01001101 (with the first zero being in bit location 7), the reader’s status is even parity (bit = 0), (skip bit location 6; it will always equal 1), the reader is not in a read cycle (bit = 0), the motor is spinning and the reader is ready to read (bit = 0), no NOVRAM error detected (bit = 0), a communications error is detected (bit = 1), the command is not received (bit = 1), and a command error is detected (bit = 1). Bit Location

Reader Function

Bit

7

Parity

6

Always set to one

5

Reader is in a read cycle

4

Motor is spinning, reader is ready to read

3

NOVRAM➀ error detected

2

Communication error detected

1

Command received

0

Command error detected ➀

Is

0 1 0 1 0 1 0 1 0 1 0 1 0 1 0

Even Odd Not Applicable Not Applicable Inactive Active Active Inactive Active Inactive Inactive Active Inactive Active Inactive

1

Active

NOVRAM status is valid only after the first status request after a NOVRAM read or write and is only valid for one read or write.

If you are using the <?> command, refer to the following table. If you Press[<?>]

The Reader Reports

Example

After power-on (NOVRAM Read)

Whether the NOVRAM was read correctly the first time the status command was received.

With the reader in a triggered mode without a serial or edge trigger present, power–off, then power–on and press [<?>]. The reader responds with <@> for a good load or <H> for a bad load.

After sending a Command

Whether the command was sent correctly.

With the reader in a triggered mode without a serial or edge trigger present, press [<?>] to clear the error flags. Then enter the desired command, <L1> for example. Press [<?>] again. The reader responds with <B> if the command was received, <C> if there was an error in the command, or <F> if there was a serial data error.

After NOVRAM Write

Whether the NOVRAM was written correctly.

The reader responds in the same manner as after power–on (NOVRAM read).

Publication 2755-6.9

Page 93

6–8

Hardware Operation

• Show Software Status, [<?1>]. Sends the following in this order: status byte, part number, ROM checksum for both possible lengths of ROM (1 megabyte and 512 bytes), NOVRAM checksum at power up, then the current NOVRAM checksum. Note: Continuous Read, 1 Output or Match Code will change the current NOVRAM checksum.

Master Label Commands • Enable Match Code Option, [<E>]. Identical to match code

• •

•

•

•

Publication 2755-6.9 command. Instructs the reader to compare bar code labels being scanned with a master label that has been entered in nonvolatile or volatile RAM, and may under certain conditions send out a relay driver signal and update internal counters. If no master label has been entered, every decoded label will be a “mismatch” and will increment the mismatch counter by one. Enable Match Code Option is intended for use when the reader is in a triggered mode. If the Match Code option is enabled in the Continuous Read mode, the reader defaults to Continuous Read, 1 Output mode, and the label data must change before the reader will output data again, unless a timeout, if enabled, occurs. Disable Match Code Option, [<F>]. Disables Match Code. Store Next Label Scanned as Master Label, [<G>]. Causes the reader to read the next bar code label scanned as the master label if Match Code has been enabled. All subsequently decoded labels are compared against the master label information stored in RAM. Download Master Label Information, [<)XXXX)>]. Downloads master label information from the host or a terminal. The master label information can be downloaded at any time, and can be saved in nonvolatile memory with a <Z> command. A stored master label will not affect standard operation unless Match Code option is enabled. Request Master Label Information, [<)>]. Immediately sends the master label information to the host. To prevent conflicts with outputting label data, press [<I>], Disable Laser Scanning command. Note: If the master label information has previously been stored in nonvolatile RAM (by a <Z> command), cycling the power will restore that information. Delete Master Label Information, [<))>]. Deletes master label information that has previously been loaded by either <)XXXX)> Download Master Label Information Command or <G> Store Next Label as Master Label command.