The text of a manual · part 20 of 27
AdaptaScan Software (Cat. No. 2755-ASN) User Manual: 12 - Uploading/Downloading Configurations
Pages 173 to 179 of 224, from AdaptaScan Software (Cat. No. 2755-ASN) User Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 173
Chapter
12
Uploading/Downloading Configurations Overview
This chapter describes how to download configurations from a computer to a single Reader or multiple Readers. Section
Helpful Hints
Page
Helpful Hints
12–2
Upload/Download Connections
12–2
Configuration Cable
12–2
Downloading a Configuration
12–3
Uploading a Configuration
12–5
When transferring configurations: Through the configuration port (direct connection)
• Use cable (Catalog No. 2755-NC48 Series B Reader, 2755-NC43 Series A Reader) and the Configuration Port connector on the Reader for downloads. You can also configure a Reader by connecting a computer to a serial port in the wiring base. (On the Serial Port dialog, you must select DF1 protocol and select the Scanner Protocol check box).
• Make sure the cable is connected to the appropriate serial port of your computer. • Communication parameters for your computer’s serial port are set under Preferences on the View menu. Configuration Port must be selected as the communications channel. Through a DeviceNet network
• A DeviceNet communications card and driver must be installed on your computer. • On the Preferences dialog (View >Preferences), DeviceNet must be selected as the communications channel. • Refer to the user instructions for the communication software you are using such as RSLinx.
Page 174
12–2
Upload/Download Connections
AdaptaScan software can download a configuration to a single Reader or multiple Readers on a DeviceNet peer-to-peer network. AdaptaScan Bar Code Reader configurations are downloaded: • directly through the Configuration Port connector on the Reader • through any Reader on the same DeviceNet peer-to-peer network
Configuration Cable (for direct transfers)
When Configuration Port is selected as the communications channel, a configuration cable is required. The configuration cable (Catalog No. 2755-NC48 Series B Reader, 2755-NC43 Series A Reader) connects the configured communications port (see Preferences, page 2–18) of the computer running AdaptaScan software to the Configuration Port connector of the Reader. Downloads may also be done through the Reader serial communication ports when scanner protocol is selected (see page 8–6).
Configuration Cable (Catalog No. 2755-NC48 Series B 2755-NC43 Series A)
9 to 25 Pin Adapter may be required
9 Pin Male D Connector 4 Pin Female Circular Connector
Personal Computer
Configuration Port Connector
Note: If you are transferring applications over a DeviceNet network, refer to the instructions provided with your computer’s DeviceNet communications card for connections. The Reader DeviceNet connections are described in the AdaptaScan Reader user manual (Publication 2755-837).
Publication 2755-838
Page 175
12–3
Downloading a Configuration
This section shows how to download a configuration to one or more Readers. Verify that your computer is connected to a Reader as shown on previous page. To download a configuration to a Reader: 1. Run the AdaptaScan software. The AdpataScan database dialog opens.
Highlight Project
2. Select and open the project containing the configuration you want to download. 3. From the Communications menu, select Go-Online. The Reader will be detected (if properly connected) and displayed in the project window. 4. Make sure each device within the project has a unique DeviceNet address (even if you are not using DeviceNet communications). With the Reader name highlighted, click the Device button to open the Device dialog and set the address. Click Apply to send the address to the Reader. If the Device is online but not in the project database, the following dialog is displayed:
If the Device is online and in the current project database, the following dialog is displayed:
Set to Unique Address
5. From the Project window, select the Reader or Readers to which you want to download a configuration. To select multiple Readers, hold down the the [Shift] or [Ctrl] control keys while making the selections. [Shift] selects a group of consecutive listings and [Ctrl] selects nonconsecutive listings.
Publication 2755-838
Page 176
12–4
6. Click the Download button to download configurations to the selected Readers. The following message appears during the download. Resetting. Sending.
Please Wait . . .
Please Wait . . .
When the download is complete, these messages disappear.
Connections to Other Readers If you attempt to download a configuration to a Reader that has connections to other Reader(s) not selected for the download, the following dialog is displayed.
The dialog shows each group of Readers that are linked together (share information). If the Readers being downloaded contain more than one group, use the Previous and Next Group buttons to view the other groups Here is an example. Assume five Readers are configured in two groups with Readers 1, 2, and 3 linked together and Readers 4 and 5 linked together. The following will occur: If a configuration is downloaded to Reader 1, a message is displayed that Readers 1, 2 and 3 are linked (share information). If Readers 1 and 4 are selected for download, a message is displayed showing that Readers 1, 2, 3 are linked together in a group and Readers 4 and 5 are linked together in a group. If all the Readers in a group are selected for download, such as Readers 1,2, and 3, no message is displayed.
Publication 2755-838
Page 177
12–5
Uploading a Configuration
The following shows how data is uploaded from a Reader to the AdaptaScan Software. 1. Open or create the project in which you want to upload the Reader configuration.
2. Make sure the configuration cable is connected to the scanner programming port. Note: You can also transfer files using a DeviceNet network connection to your computer (refer to page 2–18). 3. From the Communications menu, select Go-Online. The Reader will be detected (if properly connected) and displayed in the project window.
Note: If you go on-line with a new project and the project window doesn’t display any devices, check the query preferences as described on page 2–19.
Publication 2755-838
Page 178
12–6
4. Highlight the Reader configurations you want to upload. Readers selected for upload may or may not be part of the current project but only select Readers that are online (online Readers display the connection icon) 5. On the Project Window, click the Upload button or click the upload icon on the toolbar . The Reader configuration is uploaded to the AdaptaScan Software (in this example Reader 1).
Uploaded Configuration
6. If you open the uploaded configuration, note that all of the configuration names are set to their default values. The Reader’s label setup data is added to the existing label setups currently in the project. Shown below is the Bar Code Labels dialog.
Uploaded Label Setup
If you upload the same label data from the same or different Reader, it will use the previously existing label from the project. A duplicate label setup is not created. First Label Setup Uploaded
Publication 2755-838
Page 179
12–7
7. You can modify the uploaded configuration as required and then download the configuration again. Uploading Interconnected Readers When a Reader configuration is uploaded that has interconnections with other Readers, a dialog will be displayed asking whether or not the connections should be recreated in the project.
If you select to recreate the connections, one of the following will occur depending on whether or not the interconnected Reader configuration exists in the project:
• If the interconnected Reader is in the database, the interconnections between the Readers will be merged. • If the interconnected Reader is not in the database, a default Reader configuration will be added beginning with the name Incomplete. The uploaded interconnections are then saved using the newly created configuration. If you select to maintain the interconnections and an uploaded default Reader configuration is added in which there is a conflict with an existing interconnection, you will be prompted to choose between the uploaded connection or the existing connection.
If you select to keep the existing connection (not the uploaded connection), the uploaded Reader configuration name will be changed to begin with Incomplete and the uploaded connection information is deleted. If you select not to recreate the connections, the uploaded Reader configuration will be added to the project with a name beginning with Incomplete and the uploaded connection information is deleted.