Configuring Match Table Outputs

The Match Function Output dialog specifies the outputs that are energized when decoded symbols match data entered in the match table. Open the Match Function Output dialog by selecting the Outputs button on the Match Function dialog.

Available Outputs Displays a list of the discrete outputs you can assign to this function. Output To Displays a list of the discrete outputs assigned to this function. Add

☞ Or double-click an output name in the Available Outputs list to assign it to the match table.

Only active when an output is highlighted in the Available Outputs list. This button assigns the highlighted output to the match table. Once assigned, the output appears in the Output To list. Remove Only active when an output is highlighted in the Output To list. This button removes the highlighted output from the Output To list.

Publication 2755-838

Page 164

11–12

Configuring the Match Entry Counter

The Match Entry Counter dialog configures the match entry counter. The match entry counter increments each time decoded symbols match the data entered in the match table. Open the Match Entry Counter dialog by selecting the Counter button on the Match Function dialog.

Count Direction Determines whether the counter value increments or decrements each time a match occurs. Select:

To:

Up

Increment the counter value by 1 each time a match occurs.

Down

Decrement the counter value by 1 each time a match occurs.

Initial Value Specifies the initial value loaded into the counter. The initial value is loaded into the counter the first time the application is run or when power is cycled to the Reader. Rollover Value Specifies the value at which the counter resets to the initial value. For example if the rollover value is 5, the counter would count: 0, 1, 2, 3, 4, 5, 0, 1, 2, . . .

Publication 2755-838

Page 165

11–13

Configuring a Package Definition

The Packages dialog uses match functions to define a package. Open the Package dialog by selecting the Package button on the Match Table dialog.

Package Definitions Displays a list of packages previously defined. Select:

To:

New

Open the Package dialog allowing you to define a package using the match functions entered in the match table. Open the Package dialog for the highlighted package definition. You can also double click the package definition name to open the Package dialog.

Edit

Output To Cut Paste

Open the Package Outputs dialog for the highlighted package definition. Cut the highlighted package definition to the clipboard. Move the package definition from the clipboard to the Package Definitions list. Select Paste to make copies of a cut package definition.

Publication 2755-838

Page 166

11–14

Triggered By Specifies when the Reader activates an output if a package is decoded. Items that appear in brackets specify the same trigger assigned to the specified function. For example, selecting [Decoder] indicates that packages use the same trigger assigned to the decoding function. Highlight the package definition you want to assign a trigger for and: Select:

To:

Device

Specify the Reader that is the source of the trigger.

Input

Specify the input to provide the timing of a package output.

The following selections are typical trigger inputs.

Publication 2755-838

Select:

To:

Package Detect

Use a package detector as the trigger source.

Timer

Use the internal Reader timer as the trigger source.

ASCII Command Input Timer

Use an ASCII command as the trigger source. Use input timer 1 or 2 as the trigger source.

[Decoder]

Use the decode trigger as the trigger source.

[Match Table]

Use the match table trigger as the trigger source.

[Message]

Use the message trigger as the trigger source.

[Package]

Use the package trigger on another Reader as the trigger source.

Page 167

11–15

Configuring a Package Using Match Table Entries

The Package dialog uses match table entries to define a package. Open the Package dialog by selecting the New button on the Packages dialog.

Package Name Specifies a name for the package definition. This name appears in the list of package definitions on the Packages dialog.

Publication 2755-838

Page 168

11–16

Mode Specifies the type of match that will activate an output or increment a counter: Select:

To activate the output:

Read Package when the Reader decodes a symbol for each selected match. Use the Read Package mode to verify the presence of a good label.

No-Read Package when a no-read occurs. Use the No-Read condition to detect missing or damaged labels. A no-read occurs when a valid package has not been decoded at the end of a trigger.

Match Complete Read and No-Match when bar code data from a package matches all selected match functions. when a valid read occurs but the bar code data does not match all entries selected. Use the Read and No-Match condition to detect incorrect labels.

No-Read or No-Match when either a no-read or a no-match condition occurs (the bar code data does not match any entry in the match table). Use the No-Read or No-Match condition to detect incorrect or missing labels. when bar code data from a package does not match some or all selected match functions.

No Match Complete

Disable When selected, disables the package definition. Output At Specifies when the package detect is activated, either at the end of the trigger or when the decoded value(s) match the package definition. Match Functions A list of the available match table functions that can be used to define a package. To select more than one match function, hold down the [Shift] or [Ctrl] keys while making the selection. [Shift] selects a group of consecutive listings and [Ctrl] selects nonconsecutive listings. When all of the highlighted match functions are satisfied, a valid package has been read.

Publication 2755-838

Page 169

11–17

Configuring Package Outputs

The Package Outputs dialog specifies the outputs that are energized when decoded symbols match the data entered in the match table. Open the dialog by selecting the Output To button on the Packages dialog.

Available Outputs Displays a list of the discrete outputs that may be assigned to the match table. Output To Displays a list of the discrete outputs assigned to the package. Add

☞ Or double-click an output name in the Available Outputs list to assign it to the match table.

Only active when an output is highlighted in the Available Outputs list. This button assigns the highlighted output to the match table. Once assigned, the output appears in the Output To list. Remove Only active when an output is highlighted in the Output To list. This button removes the highlighted output from the Output To list. Output After Specifies the number of consecutive matches required before an output is turned on. Use this feature to indicate multiple, consecutive operations such as no-reads, reads, or matches.

Publication 2755-838

Page 170

11–18

Configuring the Package Counter

The Package Counter dialog configures the operation of the package counter. The package counter increments each time decoded symbols match the match table definition for the package. Open the Package Counter dialog by selecting the Counter button on the Package dialog.

Count Direction Determines whether the counter value increments or decrements each time a package is read. Select:

To:

Up

Increment the counter value by 1 each time a package is read.

Down

Decrement the counter value by 1 each time a package is read.

Initial Value Specifies the initial value loaded in the counter. The initial value is loaded the first time the application runs or when power is cycled to the Reader. Rollover Value Specifies the value at which the counter resets to the initial value. For example if the reset value is 5, the counter would increment 0,1, 2, 3, 4, 5, 0, 1, 2, 3, 4, 5, 0, 1, 2, ...

Publication 2755-838

Page 171

11–19

Configuring the Auto-Load Trigger

The Auto-Load Trigger Source dialog configures the input which initiates the the auto-load function. When triggered, auto-load automatically enters decoded bar code data into match table entries designated for auto-load. Open the Auto-Load Trigger Source dialog by selecting the Auto-Load button on the Match Table dialog.

Enable Enables and disables the autoload feature. Auto-Load Trigger Specifies the input to initiate an auto-load. Once initiated, auto-load remains active until either: • the end of the auto-load trigger • match table entries designated as an auto-load function are filled Select:

To:

Device

Specify the Reader that is the source of the trigger.

Input

Specify the input to provide the auto-load trigger.

Publication 2755-838

Page 172

11–20

Viewing Readers with Same Trigger Source

The Used By dialog lists other Readers that use the package or match table configurations as trigger sources. Use this dialog when you make changes to a match table / package definition and you want to view or access configurations assigned to the same trigger source. Open the Used By dialog by clicking the Used By button on the Match Table or Packages dialog.

Currently Used By

☞ Or double-click the package or match table definition and then click the Goto button.

Publication 2755-838

Displays the Reader configurations that use the same package or match table trigger source. Highlight the package or match table definitions you want to access and click the Goto button.