Page 130

9–9

Configuring the Timer ☞ Or double-click on Timer

The Timer dialog configures the operation of the Reader’s internal timer. Open this dialog by selecting Timer from the list on the Input & Output dialog and then clicking the Edit button.

to open the dialog.

Timer Name Specifies a unique name for the timer. This name will appear in lists where a timer trigger can be assigned. Cyclic Timer Specifies the length of time that the timer remains on before cycling off. Select:

To:

On Time

Enter a value for the length of time the timer remains on before cycling off. Enter a value between 0 and 32767 milliseconds (0 to 32.767 seconds).

Off Time

Enter a value for the length of time the timer remains off before cycling on. Enter a value between 0 and 32767 milliseconds (0 to 32.767 seconds).

Publication 2755-838

Page 131

9–10

Configuring the Input Timers 1 and 2 ☞ Or double-click on an

The Input Timer 1 and 2 function like the Package Detect with an additional timer except they are triggered by another source. Open this dialog by selecting Input Timer 1 or 2 from the list on the Input & Output dialog and clicking the Edit button.

Input Timer to open the dialog.

Timer Name Specifies a unique name for the timer. This name appears in lists where an input timer trigger can be assigned. Triggered By Specifies the trigger source that will initiate the input timer. The trigger is defined by the Reader name and input name. Device Specifies the device that is the source of the trigger. The trigger may be from the current Reader or any other Reader on the same network. Input The following selections are available as trigger input options. Select:

To:

Timer

Use the internal Reader timer as the trigger source.

ASCII Command Input Timer

Use an ASCII command input 1 or 2 as the trigger source.

DeviceNet Input Package Detect

Publication 2755-838

Use Input Timer 1 or 2 on another Reader as the trigger source. Use a DeviceNet input as the trigger source. See page 9–13. Use an external package detect as the trigger source.

[Decoder]

Use the decode trigger as the trigger source.

[Match Table]

Use the match table trigger as the trigger source.

[Package]

Use the package trigger as the trigger source.

[Message]

Use the message trigger as the trigger source.

Page 132

9–11

Timing Specifies the operation of the Input Timer. Delay Specifies delays between the trigger input and the turning on and off of the input timer. Select:

To:

On

Enter the delay (in milliseconds) between the trigger input and when the input timer turns on. Enter the delay (in milliseconds) between when the trigger input turns off and when the input timer turns off.

Off

Limits Specifies minimum and maximum on times for the input timer. Select:

To:

Minimum

Enter the minimum amount of time (in milliseconds) that the input timer can be on. Enter the maximum amount of time (in milliseconds) that the input timer can be on.

Maximum

Cyclic Operation Specifies that the input timer turns on and off for set periods after being triggered. Cyclic operation only occurs while the input trigger is active. Select:

To:

Enable

Enable cyclic operation. When not selected, the timer remains on. Enter the period of time (in milliseconds) that the input timer remains on before turning off. Enter the period of time (in milliseconds) that the input timer remains off before turning on.

On Time Off Time

Publication 2755-838

Page 133

9–12

Configuring an ASCII Trigger ☞ Or double-click on ASCII Command to open the dialog.

The ASCII Command Input dialog configures ASCII commands that the Reader will interpret as trigger on and trigger off commands. Open this dialog by selecting ASCII Command 1 or 2 from the list on the Input & Output dialog and clicking the Edit button.

ASCII Command Name Specifies a unique name for the trigger commands. This name appears in lists where an ASCII command trigger can be assigned. Use Port On Assigns the ASCII commands to a specific Reader. The ASCII trigger commands can only be assigned to a single Reader. ASCII Command Specifies the ASCII strings that the Reader interprets as a trigger on or trigger off command. Select:

To:

Turn On ➀

Enter the ASCII string that the Reader will interpret as a trigger on command. Enter the ASCII string that the Reader will interpret as a trigger off command. Enter a value for the length of time the trigger remains on if a trigger off command is not received. Enter a value between 0 and 32767 milliseconds (0 to 32.767 seconds). A value of 0 disables the timer.

Turn Off ➀ On Time

➀ The message header and trailer or message size allow the Reader to separate ASCII commands from other data.

Publication 2755-838

Page 134

9–13

DeviceNet I/O

DeviceNet Peer-to-Peer Communications Peer-to-peer communications are supported between Readers. You can easily transfer data, inputs, outputs, triggers and other data between Readers by selecting the other Readers from the configuration dialogs. However, DeviceNet peer-to-peer communication is only between Readers. The Reader does not support peer-to-peer communication with other types of DeviceNet devices. To communicate with other DeviceNet devices, you must use DeviceNet master-slave communications. Important: The maximum number of Readers that can be connected on DeviceNet peer-to-peer network is 32. Each DeviceNet network must be all peer-to-peer or all master-slave communications. You cannot mix peer-to-peer and master/slave communications on the same network. Do not use AdaptaScan DH-485 master-slave mode simultaneously with DeviceNet communications (peer-to-peer or master-slave).

DeviceNet Master-Slave Communications Connect the AdaptaScan Reader to other DeviceNet devices through either a PLC (Catalog No. 1771-SDN) or SLC (Catalog No. 1747-SDN) DeviceNet scanner. The AdaptaScan DeviceNet slave supports up to 7 discrete inputs, 15 discrete outputs, and bar code messages. The AdaptaScan operates as a slave device to the DeviceNet scanner.

Reader

Reader Other DeviceNet Devices

PLC-5 with 1771-SDN (DeviceNet Scanner)

Note: DeviceNet Input #8 and Output #16 control the transmission of bar code messages using DeviceNet master-slave. Refer to DeviceNet Messages in Chapter 10. Note: The maximum number of readers that can be connected on an AdaptaScan only DeviceNet master-slave network is 63.

Publication 2755-838

Page 135

9–14

DeviceNet Addressing The addressing of the Reader DeviceNet I/O requires 2 bytes. The following tables show the byte and bit address for each of the inputs and outputs. Use these charts when setting up the DeviceNet scanner. I/O data is addressed and sent to other DeviceNet devices through a DeviceNet scanner (Catalog No. 1771-SDN or 1747-SDN). To configure the scanner, you will need to provide the size of the I/O data, the beginning byte and bit number of the data and the destination of the I/O data. Poll Data Structure (DeviceNet Inputs) Description

Byte #

Bit #

DeviceNet Input #1

0

0

DeviceNet Input #2

0

1

DeviceNet Input #3

0

2

DeviceNet Input #4

0

3

DeviceNet Input #5

0

4

DeviceNet Input #6

0

5

DeviceNet Input #7

0

6

Poll Tx Size = 1 Byte

Response Data Structure (DeviceNet Outputs) Byte #

Bit #

DeviceNet Output #1

Description

0

0

DeviceNet Output #2

0

1

DeviceNet Output #3

0

2

DeviceNet Output #4

0

3

DeviceNet Output #5

0

4

DeviceNet Output #6

0

5

DeviceNet Output #7

0

6

DeviceNet Output #8

0

7

DeviceNet Output #9

1

0

DeviceNet Output #10

1

1

DeviceNet Output #11

1

2

DeviceNet Output #12

1

3

DeviceNet Output #13

1

4

DeviceNet Output #14

1

5

DeviceNet Output #15

1

6

Poll Rx Size = 2 Bytes

Note: Input #8 and Output #16 control the transmission of bar code message data using DeviceNet master-slave. Refer to Chapter 10.

Publication 2755-838

Page 136

9–15

Configuring DeviceNet Inputs ☞ Or double-click on a DeviceNet Input to open the dialog.

Seven discrete DeviceNet inputs are available for each Reader. These inputs are listed on the available inputs on the Input & Output dialog. Use these inputs like any other trigger source. The DeviceNet Input dialog allows you to assign a name to the input. Open this dialog by selecting a DeviceNet Input from the list on the Input & Output dialog and clicking the Edit button.

Each input can only be used once and inputs are only available for use by the Reader configuring the input. For example, if you configure a DeviceNet input for Bar Code Reader 2, you will only be able to use DeviceNet inputs from Bar Code Reader 2. Once selected, an input will not be available for use by other configurations (appears greyed out on dialogs). If you need to trigger more than one function using a single input, “chain the triggers”. For example, DeviceNet Input #1 triggers decoding on a Reader. The match function for the Reader is then triggered by the [decoder] function.

Publication 2755-838

Page 137

9–16

Configuring DeviceNet Outputs ☞ Or double-click on a DeviceNet Output to open the dialog.

Fifteen discrete DeviceNet outputs are available. These outputs are listed on the available outputs on the Input & Output dialog. Use these outputs like any other output. The DeviceNet Output dialog allows you to assign a name to the output. Open this dialog by selecting a DeviceNet Output from the list on the Input & Output dialog and clicking the Edit button.

Each output can only be used once. Once selected, an output will not be available for other configurations (appears greyed out on dialogs).

Publication 2755-838