Page 122
Chapter
9
Configuring Discrete Inputs and Outputs Chapter Objectives
This chapter defines the operation of the Reader’s discrete I/O. Section
Helpful Hints
Page
Helpful Hints
9–1
Types of Outputs
9–2
Types of Inputs
9–3
Configuring Inputs and Outputs
9–5
Configuring Discrete Inputs & the Package Detect
9–6
Configuring Discrete Outputs
9–8
Configuring the Timer
9–9
Configuring Input Timers 1 and 2
9–10
Configuring an ASCII Trigger
9–12
DeviceNet I/O
9–13
Configuring DeviceNet Inputs
9–15
Configuring DeviceNet Outputs
9–16
When setting up discrete inputs or outputs:
• If possible, use the package detect input not a discrete input for a package detector. The package detect input is used with a current sinking or hard contact detector (usually a photo-electric device). • Input and output devices have default names which can be changed. If you change the I/O name, make sure the new name describes both the type of input and the output number (1 or 2) or the input number (1 or 2).
Page 123
9–2
Types of Outputs
Each Reader can accept two I/O modules. When an output module is installed, it can be controlled by the Reader configuration or any other Reader on the same network. Discrete Output You can install two discrete output modules in the Reader’s wiring base. These modules are available with a variety of voltage and current ratings (refer to the AdaptaScan Bar Code Reader user manual). Assign discrete outputs either a normally open or normally closed state (to determine when output is energized).
Reader Positions for 2 I/O Modules
Wiring Base
Each output can be controlled by any Reader on the same network. DeviceNet Output The Reader DeviceNet communications support up to 15 discrete outputs. Use these outputs as inputs for other DeviceNet devices. Refer to page 9–13 for descriptions of DeviceNet I/O.
Publication 2755-838
Page 124
9–3
Types of Inputs
A Reader can access 6 types of inputs: a discrete input, DeviceNet input, package detect, ASCII command, timer, input timer. Use these inputs as a trigger for decoding, scanning, messages and packages. Discrete Input You can install two discrete input modules in the Reader’s wiring base. These modules are available with a variety of voltage and current ratings (refer to the AdaptaScan user manual). You can configure discrete inputs to be ON when the input is either a high or low state. In addition, inputs can be assigned a delay, debounce filter, and have a cyclic operation when ON. An input can be used by any Reader on the same network. Positions for 2 I/O Modules
Wiring Base
DeviceNet Input The Reader DeviceNet communications support up to 7 discrete inputs. Use these inputs as trigger sources for functions such as decoding, message trigger, auto-load trigger, etc. Refer to page 9–13 for descriptions of DeviceNet I/O.
Publication 2755-838
Page 125
9–4
Timer Each Reader contains an internal timer. Use a timer as a trigger for decoding, scanning, messages or packages. You can configure a timer for variable on and off times. Trigger On
Trigger On
Trigger Off
Each timer output can be used as a trigger source by any Reader on the same DeviceNet peer-to-peer network. Package Detect The package detect input functions like a discrete input (same dialog configures both) however, there is a separate terminal block connector for the package detector. Package Detector
Package Detect Terminal Block
ASCII Command Input An ASCII command from a host device that the Reader interprets as a trigger input. Specify any ASCII string to turn the trigger On/Off.
Begin Trigger End Trigger
If your ASCII command messages do not use a trailer, you must specify a message size (see Chapter 9). The trailer or message size allows the Reader to separate ASCII commands from other data. Timer Input Functions like the timer described above but is triggered by another source.
Publication 2755-838
Page 126
9–5
Selecting Inputs and Outputs
From the Input & Output dialog you select and configure the operation of the Reader’s input and output devices. Open this dialog by selecting the Input/Output button on the main Project dialog.
Inputs and Outputs Displays a listing of the inputs and outputs available to the Reader. Items that appear with a check mark are in use. Select:
To:
Package Detect
Define the package detect input.
Discrete Input/Output 1
Define the operation of the I/O module installed in position # 1 of the wiring base. Define the operation of the I/O module installed in position # 2 of the wiring base. Define the operation of the Reader’s internal timer.
Discrete Input/Output 2 Timer ASCII Command Input 1 or 2
Define the ASCII strings that a host can send as ASCII command 1 or 2. Each command contains both a trigger on and trigger off ASCII string.
Input Timer 1 or 2
Define the input timers. Input timers function like a timer but are triggered from another source. Define the discrete DeviceNet inputs available when communicating with other devices through a DeviceNet scanner module. Define the discrete DeviceNet outputs available when communicating with other devices through a DeviceNet scanner module.
DeviceNet Input 1 to 7 DeviceNet Output 1 to 15
☞ Or double-click an input or output in the Inputs & Outputs dialog to open the corresponding dialog.
Select the Edit button to open the dialog corresponding to the highlighted input or output. Used By Opens the Used By dialog for the highlighted input or output. The Used By dialog displays other Reader configurations using the same input or output. Use As Specifies whether a discrete input or output module is going to occupy the position in the wiring base.
Publication 2755-838
Page 127
9–6
Configuring Discrete Inputs and the Package Detect
The Discrete Input dialog configures the operation of the Reader’s input module(s) or package detect input. Open this dialog by selecting an input from the list on the Input & Output dialog and selecting the Edit button. Or double-click the input to open the dialog.
Input Name Specifies a name for the input. If you enter a new name, make sure the name properly identifies whether the input is a discrete input or package detect. Also, if the dialog is defining a discrete input, provide some indication for its position in the wiring base (#1 or #2). ON When Input Is Specifies whether the input is On when the signal to the input is high or low. Select:
To:
High
Turn the input ON when the input module or package detect contacts are closed (input signal present). Turn the input ON when the input module or package detect contacts are open (input signal not present).
Low
Debounce Filter When selected, adds a 15 millisecond debounce period for the input contacts. Select the debounce filter when connecting an input (discrete or package) to hard contacts. Input signals less than 15 milliseconds are ignored with the debounce filter on.
Publication 2755-838
Page 128
9–7
Timing Sets the signal duration and cycling after an input is detected. Time is specified in milliseconds (0 to 32,767). Select:
To:
On & Off Delay
Specify a delay that occurs when an input signal changes state. After an input changes state, the Reader maintains the current state for the On & Off delay period before recognizing the new state. Specify the minimum amount of time that an input remains active. If an input is on for a shorter duration than the time entered, the input duration is lengthened. Enter a value (0 to 32,767). Specify the maximum amount of time that an input remains active. If an input is on for a longer duration than the time entered, the input duration is shortened. Enter a value (0 to 32,767).
Minimum On Time
Maximum On Time
Cyclic Operation Turns the input on and off for set periods while the input is active. Select:
To:
Enable
Enable or disable cyclic operation.
On Time
Specify the amount of time in milliseconds that the input is on during a cycle. Enter 0 to 32,767. Specify the amount of time in milliseconds that the input is off during a cycle. Enter a value from 0 to 32,767.
Off Time
Limits Specifies minimum and maximum on times for the package detect or discrete input. Select:
To:
Min
Enter the minimum amount of time (in milliseconds) that the input is on. Enter the maximum amount of time (in milliseconds) that the input is on.
Max
Publication 2755-838
Page 129
9–8
Configuring Discrete Outputs ☞ Or double-click on an output
The Discrete Output dialog configures the operation of the Reader’s output module(s). Open this dialog by selecting an output from the list on the Input & Output dialog and then selecting the Edit button.
to open the dialog.
Output Name Specifies a unique name for the output. Enter a name that properly identifies the output as discrete output 1 or 2 (position in wiring base). Output State Specifies the inactive (untriggered state) of the output module contacts. Select:
To Specify:
Normally Open
The module output contacts open in the inactive (untriggered) state. The module output contacts close in the inactive (untriggered) state.
Normally Closed
On Time Specifies the length of time the output remains active after triggered. Enter a value in the range of 0 to 32,767 milliseconds (0 to 32.767 seconds). A value of 0 indicates no timing, the output on time tracks the input trigger.