Page 41

Chapter

6

Maintenance and Troubleshooting Chapter Objectives

This chapter provides troubleshooting information to assist with problem detection and resolution. It also describes how to remove the scan window for cleaning or to replace the window.

Maintenance of Scanner

! Cleaning Scan Window

ATTENTION: No user maintenance of the scanner is required. Do not open the enclosure! Removing or attempting to remove sealed screws will void the warranty.

For optimum performance the scan window should be clean. To clean the scan window:

!

ATTENTION: Only use reagent grade alcohol to clean the window. Do not use organic solvents. Do not use abrasive materials, such as disposable paper wipes, to clean the plastic scan window. Disposable wipes usually contain glass fibers which will scratch and cloud the window.

1. Turn the decoder off.

!

ATTENTION: Do not attempt to clean the window while the scanner is turned on. Although momentary exposure to the laster light is not harmful, precautions should be taken to avoid looking into the beam.

2. Verify that the POWER indicators on both the scanner and the decoder are OFF. 3. Dust off the scan window and adjacent areas with optics rated air. 4. Clean the window using a reagent grade alcohol, cotton-tipped swabs and lens cleaning paper. To avoid smearing film and fingerprints, rotate the cotton-tipped swab while it’s on the window, nearly one full turn. Then discard it. 5. Turn the decoder ON. The POWER indicators on both the decoder and scanner should be ON. When the window is clean, you will barely see the reflection of the laser beam on the window.

Page 42

6–2

Maintenance and Troubleshooting

Replacing Scan Window

The scan window fits into an opening behind the front of the scanner. A bezel and gasket create a NEMA Type 4 seal. The table below lists replacement numbers for ordering a glass or plastic window kit. Do not substitute other material for a damaged window. The windows have an optical coating necessary to scanner performance. Replacement Numbers

Window Kit Description

77125-898-01

Replacement Glass Window Kit Includes bezel/window assembly with anti-reflective, optical glass window.

77125-899-01

Replacement Plastic Window Kit Includes bezel/window assembly with hard coated, anti-reflective, optical quality, plastic window.

Figure 6.1 Scan Window Removal

Bezel/Window Assembly Bezel Screws (4)

To remove the scan window: 1. Remove four screws from front cover of scanner.

!

!

ATTENTION: Many electronic components in the scanner are static sensitive. Anyone servicing the scanner should be well grounded through an ESD strap and ground cord. For additional protection from static discharge, the scanner should be attached to the decoder. ATTENTION: Do not touch the internal mirrors! Smudges from fingerprints will deteriorate read performance. The internal mirrors cannot be serviced in the field.

2. Lift bezel/window assembly away from scanner. 3. Replace window with the appropriate window kit. 4. Tighten screws to a torque of 10 inch-pounds.

Page 43

Maintenance and Troubleshooting

Troubleshooting

6–3

This section lists problems that may occur with the scanner and/or connected decoder. Each problem lists possible causes and solutions. Problem:

“Power” indicator on both the scanner and decoder do not light. Cause: Solution:

Cause: Solution:

No incoming power. Verify power source.

Cause: Solution:

Improper connection to power source. Check connections.

Cause:

Faulty decoder. Return decoder to Allen-Bradley for repair.

Solution: Problem:

Decoder “Power” indicator lights but Scanner “Power” indicator does not light. Cause: Solution: Cause: Solution:

Problem:

Decoder power switch is in OFF position. Turn decoder power switch to ON position.

Improperly connected or faulty cable between scanner and decoder. Verify connections, replace cable. Internal decoder or scanner failure. Return scanner or decoder to Allen-Bradley for repair.

No laser beam emits from scan window. Cause: Solution:

No scan trigger signal. Verify decoder Laser On Mode and Decode Mode for proper configuration. Verify sending of scan trigger by either package detect or trigger from decoder.

Page 44

6–4

Maintenance and Troubleshooting

Problem:

“Power” indicator lights but the laser beam is not on. Cause: Solution: Cause: Solution:

Package detector not operating. Verify decoder configuration / package detect operation.

Cause:

Laser scanning mechanism is not operating correctly. Return scanner to Allen-Bradley for service.

Solution: Problem:

Decoder setup parameters are not set up properly. Verify decoder configuration.

Unable to read a label. Cause: Solution:

Decoder not configured correctly. Check decoder configuration to verify that parameters are set appropriately for your application. After making changes, SAVE configuration to EEPROM and restart decoder.

Cause: Solution:

Label(s) out of specification. Use good quality labels that are within specifications.

Cause: Solution:

Scan window is dirty. Clean window as described in previous sections of this chapter.

Cause:

Scanner is at incorrect angle or distance from bar code symbols. Check that the scanning distance is correct and orientation of labels to scanner is correct. Determine the optimum reading angle by using a static bar code label position and checking the decoder performance indicators with the Decode Mode set to Continuous. Refer to ”Compensating for Pitched Symbols”.

Solution:

Fix the scanner at a position that results in a high decoder performance value. After properly positioning the scanner, return the decoder configuration to the correct operating mode.