The text of a manual · part 6 of 9
High Performance Visible Laser Diode Scanner (Cat. No. 2755-LD4z1, -LD4z4, -LD8z1, -LD8z4) User Manual: 5 - Operating the Scanner
Pages 38 to 40 of 57, from High Performance Visible Laser Diode Scanner (Cat. No. 2755-LD4z1, -LD4z4, -LD8z1, -LD8z4) User Manual
The original document is the PDF (374 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Allen-Bradley 2755-DS
Page 38
Chapter
5
Operating the Scanner Chapter Objectives
This chapter provides information on how to operate the scanner when connected to a decoder.
Warnings and Cautions
! !
ATTENTION: Do not make any adjustments to the scanner other than those specified in this manual.
ATTENTION: If during operation an intense dot of light is generated instead of a thin line of light, immediately turn the laser off via the decoder configuration software, and then remove power from decoder.
CAUTION: This laser caution symbol appears where laser radiation is present.
Laser On/Off Control
You can disable or turn off the laser from the decoder (Catalog No. 2755-DS/DD) configuration screen by setting the Laser-on Mode parameter to Off. ➀ To turn off the laser when using a Catalog No. 2755-DM6 or -DM9 decoder, set the configuration parameters as follows: • Laser-on Mode to Triggered • Decode Trigger to Package Detect • Package Detect Input Sense to Lo = Package (Catalog No. 2755-DM9 only) If using package detect control, make sure that a package is not present. Note: Turning off the decoder will also turn off the laser. ➀ The Laser-on Mode=OFF parameter is supported only by the Catalog Number 2755-DD and -DS type decoders.
Page 39
5–2
Operating the Scanner
Scan Angle Adjustment
Each scanner has a multi-position rotary switch which lets you adjust the scan angle ∠ to !@2, #@4, or maximum angle. Catalog No. 2755-LD4 A,B,C Setting
!@2 #@4 MAX
Nominal Scan Angle 25_
Catalog No. 2755-LD4 E
Catalog No. 2755-LD8
Setting
Setting
37.5_
!@2 #@4
50_
MAX
Nominal Scan Angle 20_ 30_
!@2 #@4
40_
MAX
Nominal Scan Angle 15_ 22.5_ 30_
The scan angle adjustment switch is located behind a !@4-20 cover screw (with gasket) on the back of the scanner. This cover screw is necessary to maintain a NEMA Type 4 rating. After making the scan angle adjustment, the cover screw must be tightened to 20 inch-lbs.
!
ATTENTION: The enclosure is not completely sealed without the scan angle adjustment screw. Dust and moisture may enter the enclosure causing deterioration in performance.
Figure 5.1 Scan Angle Adjustment Switch Back View
VALID
POWER SCAN 6
Scan Angle Adjustment Switch Cover Screw
Page 40
Operating the Scanner
5–3
The scan angle adjustment switch has 4 positions: • Position #1 is full scan angle • Position #2 is 3/4 scan angle • Position #3 and #4 is 1/2 scan angle To avoid an unnecessarily long scan, rotate this switch counterclockwise. The scan angle will reduce from full to approximately #@4, and !@2. Figure 5.2 shows the scan angle relative to the switch position. In each case, the usable beam will be approximately 80% of the actual beam width. Figure 5.2 Scan Angle Adjustment Switch Positions Position #1 Full Counterclockwise
Position #2 1 Position Clockwise From Fully Counterclockwise
Position #3 1 Position Counterclockwise From Fully Clockwise
Position #4 Full Clockwise
Full Scan Angle (Factory Setting)
3/4 Scan Angle
1/2 Scan Angle
1/2 Scan Angle (same as position #3)