AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide: 11 - Communicating with a PLC-5 Processor on a DeviceNet Network, pages 201 to 207
Pages 201 to 207 of 354, from AdaptaScan Bar Code Readers (Cat. Nos. 2755-SN3, -SN5, and -SN8) Application Guide
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8
Page 201
Communicating with a PLC-5 Processor on a DeviceNet Network Overview
This application describes how to connect and configure an AdaptaScan Bar Code Reader to communicate with a PLC-5 processor over a DeviceNet network in a master/slave mode. A 4 character Interleaved 2 of 5 bar code symbol is used in this application. The DeviceNet network has the following nodes: • AdaptaScan Bar Code Reader on node 3 • 1771-SDN DeviceNet Scanner on node 1 • Computer running DeviceNet Manager Software on node 62 The DeviceNet terminal block in the reader’s wiring base connects the AdaptaScan Reader to the DeviceNet network. The wiring base has two DeviceNet terminal blocks; one for upstream connection and one for downstream connection.
Hardware Requirements
The hardware items required for this application are: • 2755-SN3, -SN5 or -SN8 AdaptaScan Bar Code Reader • 2755-NB40 or -NB41 Wiring Base • 2755-PW46 or -PW47 Power Supply • 2755-NC43 or -NC48 Configuration Cable • 1771-SDN Scanner Module (v3.04 firmware or later) • 1770-KFD DeviceNet RS-232 Interface • DeviceNet trunk cable • 1771 I/O chassis • PLC-5 processor • Computer running Windows 3.1 (or later) or Windows 95 • 9-to-25 Pin Adapter (for Computer with 25-pin COM port)
Software Requirements
The software requirements for this application are: • 2755-ASN AdaptaScan Offline Programming Software (v8.0 or later) • 6200 Series Programming Software • 1787-MGR DeviceNet Manager Software (v3.0 or later)
Publication 2755-6.8
Page 202
11–2
Communicating with a PLC-5 Processor on a DeviceNet Network
Related Publications
Related publications include: Publication
Description
2755-837
AdaptaScan Bar Code Readers User Manual
2755-838
AdaptaScan Software User Manual
1787-6.5.3
DeviceNet Manager Software Manual
1771-6.5.118
DeviceNet Scanner Configuration Manual
In addition, you may want to refer to the PLC-5 Hardware and Software User Manuals.
Connecting to the DeviceNet Network
The following illustration shows the three nodes of the DeviceNet master/slave network.
Computer 1770-KFD DeviceNet Interface Card
PLC-5 Processor 1771-SDN DeviceNet Scanner
Node 62
AdaptaScan Bar Code Reader
1787-MGR DeviceNet Manager Software 6200 Series Programming Software 2755-ASN AdaptaScan Software
Node 1 DeviceNet Trunk Cable
Connecting a Power Supply to the Reader
Node 3
DeviceNet Trunk Cable
The following illustration shows how to connect a 2755-PW46 or -PW47 power supply to a single bar code reader. Use a shielded cable (Belden 9316 recommended) to make the connections. Connect the shield to the ground screw on the reader’s wiring base. 2755-PW46 Power Supply
Reader 24V+
V-
Ground Screw on Wiring Base
Publication 2755-6.8
Page 203
Communicating with a PLC-5 Processor on a DeviceNet Network
PLC Ladder Logic
11–3
This section provides the PLC-5 ladder logic program and data monitor results. The ladder logic uses: • File N23 as the BTR file • File N22 ad the BTW file The data table shows file N23 after the AdaptaScan Reader successfully reads and transfers data ‘0300’ (from a 4 character, Interleaved 2 of 5 symbol) to the PLC-5 data table. File N23
N22
Location Word 0 Word 1 Word 0
Bit 15
Word 0
Bit 0
Word 1
Bit 7
Description Status word for SDN Scanner ‘New Message Being Sent’ bit from AdaptaScan Reader Status word 1=SDN Scanner in run mode 0=SDN Scanner in idle mode Idle mode is used to write the DeviceNet configuration to the SDN Scanner. ‘Send Message’ bit to AdaptaScan Reader
Message AddressingC Message Data is formatted the same as messages sent through the serial port. When setting up the DeviceNet scanner for addressing message data, use the following table. Description Number of Characters (LSB) Number of Characters (MSB) First Message Character (Beginning of Message) Other Message Characters from left to right Last Message Character (End of Message)
Word #
Byte #
➀➁
2 3
2
4 3
3+N where N is the number of characters in the message.
➀ Bytes #0 and #1 (word 1) are reserved for Discrete I/O. ➁ Poll Rx Size = 4 + (# of Characters in string).
Message data is addressed and sent to other DeviceNet devices through a DeviceNet scanner (Catalog No. 1771-SDN or 1747-SDN). To configure the scanner, you will need to provide the size of the message data, the beginning byte and bit number of the message and the destination of the message data.
Publication 2755-6.8
Page 204
11–4
Communicating with a PLC-5 Processor on a DeviceNet Network
Message Flow Control DeviceNet Input #8 and Output #16 control the transmission of bar code messages when using DeviceNet master-slave. Message flow control (handshaking) lets the controller know that data is available and that the reader does not send out messages faster than they can be received. Your controller logic program must transfer the message data and set the DeviceNet Input #8 (Send Next Data) for message flow control. New Data Is indicated by changing the state of DeviceNet Output #16 of the DeviceNet I/O. A change of state (0 to 1 or 1 to 0) indicates that a new message is being sent. Send Next Data Is indicated by changing the state of DeviceNet Input #8 of the DeviceNet I/O. A change of state (0 to 1 or 1 to 0) indicates that the controller is ready to receive the next message. Flow Control Example The following shows how DeviceNet Input #8 and Output #16 control the transmission of messages. Output #16 is changed by the reader and Input #8 is changed by the controller. DeviceNet Scan Number
Message Data
1 - Poll
-
1 - Response 2 - Poll 2 - Response 3 - Poll 3 - Response
Publication 2755-6.8
No Message Sent
DeviceNet Output #16 OFF (0)
Message 1 Sent
ON (1) ON (1)
Message 2 Sent
DeviceNet Input #8 OFF (0)
OFF (0) OFF (0)
Page 205
Communicating with a PLC-5 Processor on a DeviceNet Network
11–5
Note: The following ladder logic program is for reference only. Application specific interlocks may be necessary.
Note: If you are using channel B instead of channel A, bit 2 of word 0 needs to be set to 1.
Publication 2755-6.8
Page 206
11–6
Communicating with a PLC-5 Processor on a DeviceNet Network
Data Table File N23 Monitor In Data Table File N23: • N23:1 contains the DeviceNet status bits • Bit 15 is the control bit from the AdaptaScan Reader which toggles between 0 and 1 to indicate a ‘new message being sent’ • N23:2 is the byte count (4) of the message sent from the reader • N23:3 is the start the of the data read 3000. Data is actually 0300. All data is byte swapped. 1771-SDN to AdaptaScan Interface Data Table
Processor File :MASTER.ACH
Data Table File N23
Address
Data (Radix = ASCII)
N23:0
\00\00
\80\01
\00\04
3 0
0 0
\00\00
\00\00
\00\00
\00\00
\00\00
N23:10
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:20
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:30
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:40
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:50
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:60
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:70
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:80
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:90
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:100
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:110
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:120
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:130
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:140
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:150
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
Data Table File N22 Monitor Below is a partial listing of the Data Table File N22. The table shows N22:1 bit 7 as the DeviceNet status bit which toggles between 0 and 1 to indicate ‘send next message’. 1771-SDN to AdaptaScan Interface Data Table
Publication 2755-6.8
Processor File: MASTER.ACH
Address
Data (Radix=BINARY)
N22:0
0000000000000000
N22:1
0000000010000000
N22:2
0000000000000000
N22:3
0000000000000000
Data Table File N22
Page 207
Communicating with a PLC-5 Processor on a DeviceNet Network
Configuring the DeviceNet Scanner
11–7
This section describes how to configure the 1771-SDN Scanner using the DeviceNet Manager software. Before configuring the 1771-SDN Scanner, you must wire the DeviceNet network and apply DeviceNet Address of 3 to the AdaptaScan Bar Code Reader. See page 11–15. To configure the 1771-SDN DeviceNet Scanner: 1. Double-click the DeviceNet Manager icon. 2. Create a new project with the network name Network 1. 3. Click the Build Online button to create a DeviceNet network. The network should have the following nodes:
• Node 1 – 1771-SDN Scanner Module • Node 3 – 2755-SNx AdaptaScan Bar Code Reader • Node 62 – 1787-MGR DeviceNet Manager
Publication 2755-6.8