Page 149
Communicating with an SLC 5/03 Processor on a Network
9–9
4. Double-click the 1747-SDN Scanner Module to open the 1747-SDN Module Configuration dialog. From this dialog, you modify all configuration parameters for the 1747-SDN Scanner.
If you are using an AdaptaScan with v7.0 firmware on a network with 2 or less nodes, change the Interscan Delay parameter to 20 ms. This will allow the AdaptaScan more CPU time to process bar code data instead of responding to DeviceNet polls. 5. Click the Edit Scan List button.
Note: Version 8.0 of the AdaptaScan Offline Programming Software and firmware minimizes DeviceNet polling interruption of scanning.
Publication 2755-6.8
Page 150
9–10
Communicating with an SLC 5/03 Processor on a Network
6. Click the Edit I/O Parameters button.
7. Click the Polled button. 8. Change the Poll Rx size to 8. 9. Change the Poll Tx size to 1. 10. Click the OK button to return to the Scan List Editor screen. 11. Click the Datatable Map button.
Publication 2755-6.8
Page 151
Communicating with an SLC 5/03 Processor on a Network
9–11
12. Click the Data Entry button. 13. Change Map Data From to Poll Message. 14. Change Map Data To M File. 15. Change M1:1. to 1. 16. Change No. Bits to 64. 17. Click Apply Segment.
The dialog shows the data table map of the SLC M1 file. It displays data from the AdaptaScan Reader, which is mapped to the SLC (File N23). Word 0 is reserved and 4 words (8 bytes) of the data table are mapped for the incoming string from the reader. Bit 15 is the ‘new message being sent’ bit.
Publication 2755-6.8
Page 152
9–12
Communicating with an SLC 5/03 Processor on a Network
18. Click the Output button. 19. Change Map Data From to Poll Message. 20. Change Map Data To M File. 21. Change M0:1. to 1. 22. Change No. Bits to 8. 23. Click Apply Segment button.
The dialog shows the data table map of the SLC M0 file. It displays data sent to the AdaptaScan Reader through the SDN Scanner (N22). 1 byte of data is written to the SDN Scanner. Bit 7 of Word 1 is the ‘send next message’ bit. 24. Click the Close button to return to the Scanlist Editor dialog. 25. Click the Save to SDN button to download the scanlist to the 1747-SDN Scanner. Important:
Publication 2755-6.8
Before clicking the Save to SDN button , the SDN Scanner must be in Idle Mode. Set bit O:0/1 in the SLC to 0. Another way to place the SDN Scanner in Idle Mode is to put the SLC into Program Mode.
Page 153
Communicating with an SLC 5/03 Processor on a Network
Configuring the Reader
9–13
This section shows how to configure the AdaptaScan Bar Code Reader using the AdaptaScan Software (Catalog No. 2755-ASN). The procedures in this section show how to: • scan/decode 4 character, Interleaved 2 of 5 bar code symbols • define a DeviceNet address • configure the scanner • trigger the decoder • configure the format of messages and the message destination
Create a New Project Create a new project named DeviceNet Master/Slave for one AdaptaScan Bar Code Reader (Bar Code Reader 1). 1. Choose New from the Project menu to create a new project. 2. Click the New button to add a bar code reader (Bar Code Reader 1) to the project.
3. Choose Edit from the Project menu to rename the project DeviceNet Master/Slave.
If you need to change the baud rate, proceed to the next section. If you do not need to change the baud rate, proceed to step 4.
Publication 2755-6.8
Page 154
9–14
Communicating with an SLC 5/03 Processor on a Network
4. Click Save to save the project under the new name and then Close to return to the Project dialog.
Change the Baud Rate If you need to change the baud rate: 1. Click on the K Baud button and select the desired baud rate.
2. Click Save and Close to return to the Project dialog. 3. Click the Device button. 4. Click Apply if the desired baud rate is shown. 5. Click Save and Close to return to the Project dialog. 6. Click the Send Device button.
Publication 2755-6.8
Page 155
Communicating with an SLC 5/03 Processor on a Network
9–15
Define the Bar Code Label 1. Click the Labels button to open the Bar Code Labels dialog. 2. Click the New button to define a label.
3. Click the New button to define a symbol for the label.
4. From the Symbology list, select Interleaved 2 of 5. 5. Under Lengths, select the Length 1 check box and then type 4 in the Through box. This indicates a 4 character length for Interleaved 2 of 5 labels. 6. Click OK until you return to the Bar Code Labels dialog. 7. Click Save and then Close to return to the main Project dialog.
Publication 2755-6.8
Page 156
9–16
Communicating with an SLC 5/03 Processor on a Network
Define the DeviceNet Address 1. Click the Device button on the Project dialog.
2. Set the DeviceNet address to 3. 3. Connect the 2755-NC43 or -NC48 Configuration Cable to the reader. 4. Click the Apply button. 5. Click Save and Close to return to the Project dialog.
Configure the Scanner 1. Click the Scanner button on the Project dialog to open the Scanner dialog.
2. Configure the scan pattern and use the Focus procedure for optimum scanner focus. 3. Click the Apply button to send the scanner configuration to the AdaptaScan Bar Code Reader. 4. Click the Close button and return to the Project dialog.