Communicating with an SLC 5/03 Processor on a Network Overview
This application describes how to connect and configure an AdaptaScan Bar Code Reader to communicate with an SLC 5/03 processor over a DeviceNet network in a master/slave mode. A 4 character Interleaved 2 of 5 bar code symbol is used in this application. The DeviceNet network has the following nodes: • AdaptaScan Bar Code Reader on node 3 • 1747-SDN DeviceNet Scanner on node 1 • Computer running DeviceNet Manager Software on node 62. The DeviceNet terminal block in the reader’s wiring base connects the AdaptaScan Reader to the DeviceNet network. The wiring base has two DeviceNet terminal blocks; one for upstream connection and one for downstream connection.
Hardware Requirements
The hardware items required for this application are: • 2755-SN3, -SN5 or -SN8 AdaptaScan Bar Code Reader • 2755-NB40 or -NB41 Wiring Base • 2755-PW46 or -PW47 Power Supply (if not power by DeviceNet) • 2755-NC43 or -NC48 Configuration Cable • 1747-SDN Scanner Module (v2.05 firmware or later) • 1770-KFD DeviceNet RS-232 Interface Box • RS-232 cable for the RS-232 Interface Box • DeviceNet trunk cable • 1746 Chassis and 24V dc Power Supply • SLC 5/03 processor • Computer running Windows 3.1 (or later) or Windows 95 • 9-to-25 Pin Adapter (for Computer with 25-pin COM port)
Software Requirements
The software requirements for this application are: • 2755-ASN AdaptaScan Offline Programming Software (v8.0 or later) • SLC Advanced Programming Software • 1787-MGR DeviceNet Manager Software (v3.0 or later)
Publication 2755-6.8
Page 142
9–2
Communicating with an SLC 5/03 Processor on a Network
Related Publications
Related publications include: Publication
Description
2755-837
AdaptaScan Bar Code Readers User Manual
2755-838
AdaptaScan Software User Manual
1787-6.5.3
DeviceNet Manager Software Manual
1747-6.5.2
1747-SDN DeviceNet Scanner Configuration Manual
In addition, you may want to refer to the SLC 500 Hardware and Software User Manuals.
Connecting to the DeviceNet Network
The following illustration shows the nodes of the DeviceNet master/slave network. You must terminate the first and last node in the network. Refer to the 1747-SDN DeviceNet Scanner Configuration Manual (Publication No. 1747-6.5.2) for more information regarding user termination information.
Computer 1770-KFD DeviceNet Interface Box
SLC 5/03 Processor 1747-SDN DeviceNet Scanner
Node 62
AdaptaScan Bar Code Reader
1787-MGR DeviceNet Manager Software SLC 500 Advanced Programming Software 2755-ASN AdaptaScan Software
Node 1
DeviceNet Trunk Cable
Connecting a Power Supply to the Reader
Node 3
DeviceNet Trunk Cable
The following illustration shows how to connect a 2755-PW46 or -PW47 power supply to a single bar code reader. Use a shielded cable (Belden 9316 recommended) to make the connections. Connect the shield to the ground screw on the reader’s wiring base. 2755-PW46 Power Supply
Reader 24V+
V-
Ground Screw on Wiring Base
Note: Use a termination switch for DeviceNet in the wiring base for the end of the network. Publication 2755-6.8
Page 143
Communicating with an SLC 5/03 Processor on a Network
SLC Ladder Logic
9–3
This section provides the SLC ladder logic program and data monitor results. The ladder logic uses: • File N23 as the SLC interface to M1 file • File N22 as the SLC interface to M0 file The data table shows file N23 after the AdaptaScan Reader successfully reads and transfers data ‘0300’ (from a 4 character, Interleaved 2 of 5 symbol) to the SLC data table. File
Location
Discrete Output O
Word 0 Bit 0
N23 N22
Word 0 Word 1 Bit 15 Word 0 Word 1 Bit 7
Description 1=SDN card in run mode 0=SDN card in idle mode Status word ‘New Message Being Sent’ bit from AdaptaScan Reader Status word ‘Send Message’ bit to AdaptaScan Reader
Message AddressingA Message Data is formatted the same as messages sent through the serial port. When setting up the DeviceNet scanner for addressing message data, use the following table. Description Number of Characters (LSB) Number of Characters (MSB) First Message Character (Beginning of Message) Other Message Characters from left to right Last Message Character (End of Message)
Word #
Byte #
➀➁
2 3
2
4 3
3+N where N is the number of characters in the message.
➀ Bytes #0 and #1 (word 1) are reserved for Discrete I/O. ➁ Poll Rx Size = 4 + (# of Characters in string).
Message data is addressed and sent to other DeviceNet devices through a DeviceNet scanner (Catalog No. 1771-SDN or 1747-SDN). To configure the scanner, you will need to provide the size of the message data, the beginning byte and bit number of the message and the destination of the message data.
Publication 2755-6.8
Page 144
9–4
Communicating with an SLC 5/03 Processor on a Network
Message Flow Control DeviceNet Input #8 and Output #16 control the transmission of bar code messages when using DeviceNet master-slave. Message flow control (handshaking) lets the controller know that data is available and that the reader does not send out messages faster than they can be received. Your controller logic program must transfer the message data and set the DeviceNet Input #8 (Send Next Data) for message flow control. New Data Is indicated by changing the state of DeviceNet Output #16 of the DeviceNet I/O. A change of state (0 to 1 or 1 to 0) indicates that a new message is being sent. Send Next Data Is indicated by changing the state of DeviceNet Input #8 of the DeviceNet I/O. A change of state (0 to 1 or 1 to 0) indicates that the controller is ready to receive the next message. Flow Control Example The following shows how DeviceNet Input #8 and Output #16 control the transmission of messages. Output #16 is changed by the reader and Input #8 is changed by the controller. DeviceNet Scan Number
Message Data
1 - Poll
-
1 - Response 2 - Poll 2 - Response 3 - Poll 3 - Response
Publication 2755-6.8
No Message Sent
DeviceNet Output #16 OFF (0)
Message 1 Sent
ON (1) ON (1)
Message 2 Sent
DeviceNet Input #8 OFF (0)
OFF (0) OFF (0)
Page 145
Communicating with an SLC 5/03 Processor on a Network
9–5
Note: The following ladder logic program is for reference only. Application specific interlocks may be necessary. Rung 2:0 This rung enables Discrete Output bit 0 of slot 1. This will put the 1747-SDN card into run mode. Remember in order to “save to sdn” from the DeviceNet Manager Software you must disable this bit or put the processor into program mode.
Publication 2755-6.8
Page 146
9–6
Communicating with an SLC 5/03 Processor on a Network
N23 Data Table File Monitor In Data Table File N23: • N23:1 contains the DeviceNet status bits • Bit 15 is the control bit from the AdaptaScan Reader which toggles between 0 and 1 to indicate a ‘new message being sent’ • N23:2 is the byte count (4) of the message sent from the reader • N23:3 is the start the of the data read 3000. Data is actually 0300. All data is byte swapped. Note: The SLC instruction SWP can be used to swap the bar code data only. 1747-SDN to AdaptaScan Interface Data Table
Processor File :MASTER.ACH
Data Table File N23
Address
Data (Radix = ASCII)
N23:0
\00\00
\80\01
\00\04
3 0
0 0
\00\00
\00\00
\00\00
\00\00
\00\00
N23:10
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:20
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:30
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:40
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:50
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:60
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:70
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:80
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:90
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:100
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:110
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:120
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:130
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:140
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N23:150
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
\00\00
N22 Data Table File Monitor Below is a partial listing of the Data Table File N22. The table shows N22:1 bit 7 as the DeviceNet status bit which toggles between 0 and 1 to indicate ‘send next message’. 1747-SDN to AdaptaScan Interface Data Table
Publication 2755-6.8
Processor File: MASTER.ACH
Address
Data (Radix=BINARY)
N22:0
0000000000000000
N22:1
0000000010000000
N22:2
0000000000000000
N22:3
0000000000000000
Data Table File N22
Page 147
Communicating with an SLC 5/03 Processor on a Network
9–7
Data Table File 0 Monitor Below is a partial listing of the File 0 data table. The table shows that bit O:1/0 is set to enable run mode in the 1747-SDN Scanner (1=RUN; 0=IDLE). 1747-SDN to AdaptaScan Interface Data Table Address
Processor File :MASTER.ACH
Data Table File O
Data (Radix = ASCII)
O:1
\00\01
O:1.1
\00\00
O:1.2
\00\00
O:1.3
\00\00
O:1.4
\00\00
O:1.5
\00\00
O:1.6
\00\00
O:1.7
\00\00
O:1.8
\00\00
O:1.9
\00\00
O:1.10
\00\00
O:1.11
\00\00
O:1.12
\00\00
O:1.13
\00\00
O:1.14
\00\00
O:1.15
\00\00
Data Table File M1 Monitor Below is a partial listing of the M1 data table. • M1:1.1 contains the DeviceNet status bit • M1:1.2 is the byte count (4) of a message • M1:1.3 to M1:1.4 is data 0300 from the AdaptaScan Reader 1747-SDN to AdaptaScan Interface Data Table Address
Processor File :MASTER.ACH
Data Table File M1:1
Data (Radix = ASCII)
M1:1
\00\00
M1:1.1
\80\01
M1:1.2
\00\04
M1:1.3
3 0
M1:1.4
0 0
M1:1.5
\00\00
M1:1.6
\00\00
M1:1.7
\00\00
M1:1.8
\00\00
M1:1.9
\00\00
M1:1.10
\00\00
M1:1.11
\00\00
M1:1.12
\00\00
M1:1.13
\00\00
M1:1.14
\00\00
M1O:1.15
\00\00
Publication 2755-6.8
Page 148
9–8
Communicating with an SLC 5/03 Processor on a Network
Configuring the DeviceNet Scanner
This section describes how to configure the 1747-SDN Scanner using the DeviceNet Manager software. Before configuring the 1747-SDN Scanner, you must wire the DeviceNet network and apply DeviceNet Address 3 to the bar code reader. See page 9–16. To configure the 1747-SDN DeviceNet Scanner: 1. Double-click the DeviceNet Manager icon. 2. Create a new project with the network name SLC503. 3. Click the Build Online button to create a DeviceNet network. The network should have the following nodes:
• Node 1 – 1747-SDN Scanner Module • Node 3 – 2755-SN5 AdaptaScan Bar Code Reader • Node 62 – 1787-MGR DeviceNet Manager
Publication 2755-6.8