AdaptaScan Bar Code Readers Application Guide Document Update: Purpose of this Document

Pages 1 to 12 of 48, from AdaptaScan Bar Code Readers Application Guide Document Update

The original document is the PDF (529 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort 2755-SN3, Accu-Sort 2755-SN5, Allen-Bradley 2755-SN5, Accu-Sort 2755-SN8 and Allen-Bradley 2755-SN8

Page 1

Document Update

- (Catalog Numbers 2755-SN3, -SN5, -and -SN8) Purpose of this Document

This document update revises the following publication. Keep this document update for reference. Publication

Description

2755-6.8

AdaptaScan Bar Code Readers Application Guide

Summary of Update

The following sections summarize the information contained in this Document Update. Changes are presented as those that effect the entire document or for a specific chapter in the document.

Changes that Effect the Entire Document

The following provides an update for changes that effect the entire document.

Application Guide Database File There is now an Application Guide Database File containing all of the applications found in the AdaptaScan Bar Code Readers Application Guide (Publication No. 2755-6.8). The file is included as part of the AdaptaScan Installation Files. File APPGUIDE.DBF

Function Database containing example projects from the AdaptaScan Application Guide.

Page 2

2

Bar Code Readers Application Guide

Project Database Dialog Box Starting with version 11.x is a new project database dialog box that allows you to select or create a database file. You can use this to help organize your project. From the Start menu, select Programs>AdaptaScan OLP>AdaptaScan OLP. The database dialog opens.

You can create multiple database (.DBF) files with different projects.

Publication 2755-6.8.1

Page 3

Bar Code Readers Application Guide

3

Project Dialog Box There is a new Project dialog box that offers Upload/Download functionality.

The buttons on the Project window are defined below. Select:

To: Create a new Bar Code Reader configuration (Bar Code Reader 1, Bar Code Reader 2, Bar Code Reader 3, ...) in the Project window. Delete the selected Bar Code Reader configuration from the Project window. Define label setups and symbologies for Reader operation. Define a unique name and enter a description for the Reader. Also defines a address for the Reader. Specify linear or raster scanning, how scanning is triggered, and access the focus function. Define when the Reader decodes data and what label is decoded. Also defines the inter-symbol timer and performance indicator parameters. Define the operation for package detector, discrete inputs, discrete outputs, timer and ASCII trigger commands. Define communication parameters (RS-232, RS-485/RS422) and protocols (ASCII, DH-485, DF1) for the Reader’s communication ports. Define match table, package and counter functions for decoded bar code data. Define the format and content of messages sent to the host after bar codes are decoded. Transfer the configuration stored in a Reader to the currently opened project in the AdaptaScan Software. Downloads the highlighted configurations to the reader or network. View the operation of a single Reader or another Reader on the same network. Compare the Reader configuration within the project with the on–line device. Download new firmware to a selected Reader.

Publication 2755-6.8.1

Page 4

4

Bar Code Readers Application Guide

Toolbar Version 11.x offers a new toolbar. Turn the tool bar view on or off from the View menu. The tool icons provide shortcuts to the following menu items:

Move the toolbar to any side of the window or detach the toolbar and place anywhere on your screen by clicking on and holding down the mouse key while dragging the toolbar.

Default Position

Bottom Position

Detached

Publication 2755-6.8.1

Side Window

Page 5

Bar Code Readers Application Guide

5

The following provides a brief summary of the AdaptaScan tools. Tool or Select from menu:

Icon

Description

Create New Database

File >New

Creates a database file that will contain project configuration files.

Open Existing Database

File >Open

Opens window allowing you to select an existing database file (.dbf) containing project configuration files.

Open Selected Project

Project >Open

Opens the project currently selected in the AdaptaScan database file window.

Create New Project

Project >New

Creates a new project within the currently open database file (.dbf).

Go On-Line

On-Line Tools >Go On-Line

Connects the programming computer to the network.

Go Off-Line

On-Line Tools >Go Off-Line

Disconnects the programming computer from the network.

Upload Selected Configuration into Project

On-Line Tools >Upload

Uploads the configuration stored in the selected reader to the current project.

Download Selected Configurations to Network

On-Line Tools >Download

Downloads the selected Reader configuration(s) to the Readers on the network.

Open Monitor Window

On-Line Tools >Monitor

Opens on-line monitor window.

Compare Project Configuration with On-Line Device

On-Line Tools >Compare

Compares the configuration database of the currently selected Reader to the actual configuration stored within the Reader.

Cut Selection to Clipboard

Edit >Cut

Removes the currently selected item from the dialog or window and places the item on the clipboard.

Copy Selection to Clipboard

Edit >Copy

Copies the currently selected item from the dialog or window and places the copy on the clipboard.

Paste Clipboard Contents

Edit >Paste

Pastes the last item placed on the clipboard to the currently selected location.

Print

File >Print

Opens the print dialog that allows you to print out an application report.

About AdaptaScan Software

Help >About Off-Line Programmer

Opens a dialog showing the software revision and serial numbers along with other software information.

On-Line Context Help

Help >Contents

When selected, displays a pointer. this pointer may be moved to an area on a dialog or menu and clicked for help about the item.

Publication 2755-6.8.1

Page 6

6

Bar Code Readers Application Guide

Online Tools There are new online tools – project window icons. The project window status icons display the status of the Reader connections and configurations.

Connection Indicates device is on-line

Database Indicates Configuration is stored in the database

Device Icon Graphic representing the type of device

Connection When displayed, indicates a connection was made to the device: • Yellow (default) indicates that the AdaptaScan software does not have the information required to determine whether the device’s configuration matches the configuration in the software database. • Green appears after a Compare operation (see page 11) was performed and the configuration of the on-line reader matches the database configuration. • Red appears after a Compare operation (see page 11) was performed and the configuration of the on-line reader does not match the database configuration. Database When displayed, indicates that a database configuration exists for the Reader. The color indications are the same as for the Connection icon (see descriptions above). Device Icon Displays the icon associated with the device. Here are some common device icons: = AdaptaScan Reader

= SDN Scanner Card

Publication 2755-6.8.1

= PhotoEye photo-electric detector

= KFD DeviceNet Personal Computer Interface

Page 7

Bar Code Readers Application Guide

7

Cut, Copy, and Paste You can now cut, copy, and paste some items within and between database files: • projects • Reader configurations • match fields • message fields • labels • label fields The cut, copy, and paste icons and menu selections will only be available where they can be used. Otherwise the icons will appear grayed out. Important: Cutting or copying and then pasting a Reader configuration is different from importing/exporting Reader configurations. When an individual Reader configuration is pasted into a project, only the original Reader’s configuration dialog boxes are copied and recreated in the new project. Connections to and from the original configuration are not recreated using Paste. If you use import/export, the connections to the original module are maintained. Paste is useful when you need to make a configuration similar to an existing configuration in the currently open project or another project. When you need to make an exact copy of a configuration, copy and paste the entire project in the AdaptaScan database dialog or use the import/export functions (see next page).

Publication 2755-6.8.1

Page 8

8

Bar Code Readers Application Guide

Import/Export Configurations You can now import/export configurations. Using the import/export functions you can transfer exact copies of Reader configurations between projects. The imported/exported configurations maintain the internal and external connections. 1. Open the project you want to import the configuration file into. 2. From the File menu, select Import. The Import Configuration dialog is displayed.

3. Enter the path>filename of the Reader configuration you want to import (.cfg file). 4. Click Open to import the Reader configuration into the project.

Publication 2755-6.8.1

Page 9

Bar Code Readers Application Guide

9

Online Functionality There is now an online function. The Go On-Line command establishes communications between the AdaptaScan software and the reader or DeviceNet network using the communication channel specified on the Preferences dialog. To go on-line with AdaptaScan software: Go On-Line

1. Click the Go On-Line icon or select Go On-Line from the Communications menu. The project window will display the devices on the network along with their catalog no. and address. Note: The Query dialog may be displayed when you go on-line (depending on your preference settings).

Note: If you are connected to the DeviceNet network using the Reader configuration cable, only AdaptaScan Readers on the network are identified and displayed. When connecting using a DeviceNet communications card and driver software on your computer, all DeviceNet nodes on the network are identified and displayed. 2. Highlight individual readers in the list to display the currently loaded firmware revision and their configuration status.

Publication 2755-6.8.1

Page 10

10

Bar Code Readers Application Guide

When going on-line: • You can only be on-line with one project at a time. Use the Go Off-Line command (Communications menu) when you want to switch to another project. • Upload, Download, Monitor and Compare functions are only available for AdaptaScan Readers having the same major version number as the AdaptaScan software (firmware version 11.x or greater) • The Firmware button, for downloading firmware to a Reader, is only available when the communications channel is set for Configuration Port (direct connection using configuration cable). • Use Refresh (Communications menu) to query the network and update the display. • Use Query (View menu) to display the Query dialog. The Query dialog allows you to specify the network addresses read when on-line functions are used. By only checking the addresses that are required, you can increase the speed at which network operations occur.

Publication 2755-6.8.1

Page 11

Bar Code Readers Application Guide

11

Compare Tool The Compare Tool compares the calculated Cyclic Redundancy Check (CRC) of the configuration stored in the project database with the CRC of the configuration stored in the Reader. Compare is useful when checking if a Reader’s configuration has been changed to determine if an upload or download is necessary. Note: Compare is not available if you are using peer-to-peer connections (data, triggers, or I/O shared between Readers). In addition, cut and copied Reader configurations between projects may not match when compared due to differences in the label configurations between projects. To use compare: Go On-Line

Compare

1. Make sure the software is on-line by clicking the Go On-Line icon or by selecting Go On-Line from the Communications menu. Note: The Query dialog may be displayed when you go on-line (depending on your preference settings). 2. Select the Reader configuration you want to compare with the actual configuration stored within the Reader. 3. Click the Compare tool icon or select Compare from the Communications menu.

Connection Icon

Database Icon

If the Reader configuration has been compared and does not match the configuration stored in the Reader, the connection icon appears red. If the Reader configuration has been compared and matches the configuration stored in the Reader, the database and connection icons appear green. If a Reader configuration has not been compared to the configuration stored in a Reader, the database and connection icons appear yellow.

Publication 2755-6.8.1

Page 12

12

Bar Code Readers Application Guide

Message Format The Message Format dialog box has changed. You now have Swap and Pad check box and Handshaking enabled or disabled

Swap and Pad When selected, high and low data bytes swap positions. Select swap bytes when data is sent in the wrong order (high byte first). For example, data to a PLC is sent with the first character of a string in the second byte. By swapping the bytes, the first character corresponds to the first byte. When selected, uneven numbered data is padded with a zero so that messages always contain an even number of bits. Handshaking When selected, allows the PLC or to use bits in the DeviceNet assembly objects to control the transfer of message data.

Publication 2755-6.8.1